TPI BD24-2-WHS

TPI BD242WHS Whole House Fan Instruction Manual

Model: BD24-2-WHS

1. Product Overview

The TPI BD242WHS is a 24-inch belt-drive whole house fan designed for efficient ventilation in commercial, greenhouse, and shop environments. This unit features a powerful 1/3 HP motor with two speeds, providing customizable airflow. It is equipped with automatic shutters that open when the fan is active and close when it is off, contributing to energy efficiency.

Manufactured by TPI Corporation, this fan is built for durability and reliable performance, ensuring effective air circulation and temperature regulation.

TPI BD242WHS 24-inch Whole House Fan with belt drive and automatic shutters

Image 1.1: The TPI BD242WHS 24-inch Whole House Fan, showcasing its belt-drive motor, fan blades, and the frame designed for wall installation. The automatic shutters are visible at the bottom.

2. Safety Information

WARNING: Read all safety warnings and instructions before installing or operating this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Electrical Safety: Ensure the power supply matches the fan's requirements (120V). All wiring must be performed by a qualified electrician and comply with local electrical codes. Disconnect power before servicing or cleaning.
  • Installation Safety: Mount the fan securely to a structurally sound surface. Ensure proper clearance around the fan for optimal airflow and to prevent obstruction. Keep hands, hair, and loose clothing away from moving parts.
  • Operation Safety: Do not operate the fan with damaged cords or plugs. Do not insert objects into the fan grille. Keep children and pets away from the operating fan.
  • Maintenance Safety: Always disconnect power before performing any maintenance. Use appropriate personal protective equipment (PPE) if necessary.

3. Product Features and Benefits

  • Powerful 2-Speed Motor: Equipped with a 1/3 HP motor, this fan offers two speed settings for efficient and customizable airflow, suitable for both residential and industrial applications.
  • Automatic Shutters: Features self-operating shutters that automatically open when the fan is turned on and close when it's turned off, ensuring efficient operation and contributing to energy savings.
  • High-Quality Construction: Built to withstand industrial demands, the fan resists wear, corrosion, and mechanical stress, ensuring a long lifespan and consistent performance.
  • Efficient Airflow and Versatility: Delivers effective air circulation, distributing heat evenly across the space for enhanced comfort. Its dimensions allow it to fit a variety of interiors.
  • Easy Maintenance: Designed for straightforward cleaning with mild detergent and a scrubbing brush, ensuring optimal performance year-round. Avoid harsh chemicals.

4. Specifications

AttributeValue
Model NumberBD24-2-WHS
BrandTPI
Product Dimensions (D x W x H)14.5" x 28" x 29.5"
Weight40 Pounds
Motor Horsepower1/3 HP
Amperage4.8-5.7 Amps
Voltage120V
Number of Blades3
Fan DesignExhaust Fan
Power SourceCorded Electric

5. Setup and Installation

Installation of the TPI BD242WHS whole house fan typically involves mounting the unit into a wall opening, often in an attic or a dedicated ventilation space. Due to the electrical requirements and the need for secure structural mounting, professional installation is highly recommended.

Key Installation Considerations:

  • Location: Choose a location that allows for effective air circulation throughout the desired area (e.g., house, greenhouse, shop). Ensure adequate attic or exhaust venting is available to allow hot air to escape.
  • Framing: A sturdy frame must be constructed to support the fan's weight and dimensions (14.5"D x 28"W x 29.5"H). This may involve cutting and reinforcing joists.
  • Electrical Connection: The fan requires a 120V power supply. All electrical connections must adhere to national and local electrical codes. Ensure the circuit can handle the fan's amperage (4.8-5.7 Amps). A dedicated circuit may be necessary.
  • Shutter Clearance: Ensure the automatic shutters have sufficient space to open and close freely without obstruction.
  • Vibration Isolation: Consider using vibration-dampening materials between the fan frame and the mounting structure to minimize noise transmission.

Refer to the detailed installation diagrams and instructions provided in the physical product manual for precise measurements and wiring schematics.

6. Operation

The TPI BD242WHS fan is designed for straightforward operation with its 2-speed motor and automatic shutters.

Operating Instructions:

  1. Power On: Ensure the fan is properly installed and connected to a power source.
  2. Select Speed: Use the fan's control switch (not included, typically a wall switch or thermostat) to select the desired speed setting (low or high).
  3. Automatic Shutters: Upon activation, the fan's automatic shutters will open to allow airflow. When the fan is turned off, the shutters will automatically close, helping to seal the opening and prevent heat loss or gain.
  4. Optimal Use: For best results, operate the fan during cooler parts of the day or evening to draw in cooler outside air and expel warmer indoor air. Ensure windows or doors are open in the living space to create a cross-ventilation effect.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your TPI BD242WHS whole house fan.

Cleaning and Care:

  • Disconnect Power: ALWAYS disconnect the fan from the power supply before attempting any cleaning or maintenance.
  • Fan Blades and Grille: Periodically clean the fan blades and protective grille to remove accumulated dust, dirt, and debris. Use a mild detergent solution and a soft cloth or scrubbing brush.
  • Avoid Harsh Chemicals: Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the fan's finish and components.
  • Motor and Belt: Inspect the motor and belt for any signs of wear, damage, or excessive dust buildup. The belt tension should be checked periodically. Consult a qualified technician for any motor or belt adjustments or replacements.
  • Shutters: Ensure the automatic shutters are clean and move freely. Lubricate hinges if necessary with a silicone-based lubricant.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your TPI BD242WHS whole house fan. For problems not listed here, or if solutions do not resolve the issue, contact a qualified technician or TPI customer support.

ProblemPossible CauseSolution
Fan does not turn on.No power, tripped circuit breaker, faulty switch, motor issue.Check power supply and circuit breaker. Ensure switch is in "ON" position. If problem persists, consult an electrician.
Reduced airflow.Dirty blades/grille, obstructed intake/exhaust, loose belt.Clean fan blades and grille. Ensure attic vents are clear. Check belt tension and condition.
Unusual noise or vibration.Loose mounting, unbalanced blades, worn motor bearings, loose/worn belt.Check mounting bolts for tightness. Inspect blades for damage or debris. Consult a technician for motor or belt issues.
Shutters not opening/closing properly.Obstruction, dirty hinges, damaged mechanism.Clear any obstructions. Clean and lubricate hinges. Inspect for physical damage.

9. Warranty and Support

For information regarding the manufacturer's warranty for your TPI BD242WHS Whole House Fan, please refer to the warranty documentation included with your purchase or visit the official TPI Corporation website. TPI Corporation is known for its commitment to quality and customer satisfaction.

For technical support, parts, or service inquiries, please contact TPI Corporation directly. Contact information can typically be found on the product packaging, the official TPI website, or through your authorized dealer.

Manufacturer: TPI Corporation

For more information about TPI Corporation and their range of products, you may visit their official website: www.tpicorp.com

Related Documents - BD24-2-WHS

Preview TPI 9075 Wireless Accelerometer: Instruction Manual and Specifications
Detailed instruction manual and technical specifications for the TPI 9075 Wireless Smart Vibration Sensor. Learn about its features, setup, operation, vibration analysis, and warranty information.
Preview ATEX Compliance: Understanding Hazardous Atmospheres and Equipment Safety
An informative guide to ATEX regulations, hazardous area classifications (Zones), gas groups, and temperature classifications. Features the TPI 9085Ex Smart Vibration Analyser as a solution for ATEX compliance.
Preview TPI Digital Manometer 608 & 608BT User Manual and Specifications
Comprehensive user manual for the TPI Digital Manometer 608 and 608BT, detailing product specifications, operating instructions, measurement techniques, troubleshooting, warranty information, and Bluetooth connectivity features with the TPI View App.
Preview TPI Condition Based Monitoring Instruments for Pumps, Fans, and Motors
Explore Test Products International's (TPI) range of Condition Based Monitoring (CBM) instruments, including vibration analyzers, monitors, and sensors designed for pumps, fans, and motors. Learn about features, specifications, and software solutions for effective machine health analysis.
Preview TPI Scope Plus 460: 20MHz Handheld Digital Oscilloscope User's Guide
Comprehensive user's guide for the TPI Scope Plus 460 handheld digital oscilloscope, detailing features, specifications, operation, advanced functions, safety, maintenance, and troubleshooting for effective use.
Preview TPI 717R Combustion Flue Gas Analyser User Manual
Comprehensive user manual for the TPI 717R Combustion Flue Gas Analyser, detailing its functions, operation, specifications, calibration, troubleshooting, and warranty information.