Introduction
This manual provides essential instructions for the safe and efficient operation, installation, maintenance, and troubleshooting of your Migali C-SP60-16-HC 60-inch, 16-pan sandwich prep table. Please read this manual thoroughly before operating the unit and retain it for future reference.

Image: Front view of the Migali C-SP60-16-HC sandwich prep table, showcasing the top section with food pans and a cutting board, and two refrigerated storage doors below.
Safety Information
Always adhere to basic safety precautions when using this appliance to reduce the risk of fire, electric shock, or injury. This unit is designed for commercial use and should be operated by trained personnel only.
- Ensure the unit is properly grounded.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Do not damage the refrigerant circuit.
- Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
Unpacking and Installation
Unpacking
Carefully remove all packaging materials. Inspect the unit for any shipping damage. Report any damage immediately to the carrier and your supplier. Do not discard packaging until the unit has been inspected and is confirmed to be in good working order.
Location
Place the unit on a strong, level surface capable of supporting its weight. Ensure adequate clearance around the unit for proper ventilation. Avoid direct sunlight or proximity to heat-generating equipment.

Image: Front view of the Migali C-SP60-16-HC sandwich prep table, showing the two doors and the top prep area.

Image: Side view of the Migali C-SP60-16-HC sandwich prep table, highlighting the stainless steel construction.

Image: Rear view of the Migali C-SP60-16-HC sandwich prep table, showing the compressor compartment and power cord.
Electrical Connection
The unit requires a dedicated electrical circuit. Ensure the power supply matches the specifications on the unit's data plate. The unit is equipped with a Nema 5-15P plug. Do not use extension cords or adapter plugs.
Casters
This unit ships with wheels preinstalled for convenient positioning. Ensure all casters are locked once the unit is in its final location to prevent movement.
Operating Instructions
Initial Startup
After installation, allow the unit to sit for at least 2 hours before plugging it in. This allows refrigerants and oils to settle. Plug the unit into a grounded outlet. The digital temperature controller will display the current internal temperature.

Image: Close-up of the digital temperature controller and power switches on the Migali sandwich prep table.
Temperature Control
The unit features a digital temperature controller for precise temperature management. Refer to the controller's specific instructions for setting the desired temperature. The robust forced air refrigeration system ensures rapid cooling and temperature stability for both the top pan section and the refrigerated storage below.

Image: View of the internal fan and airflow system within the refrigerated compartment, illustrating the forced air refrigeration.
Loading the Unit
Ensure food pans are properly seated in the top section. Do not overload the refrigerated compartments to allow for proper air circulation. The unit is designed to hold 16 pans in the top section.

Image: Close-up of an adjustable wire shelf inside the refrigerated storage compartment.
Maintenance
Cleaning
Regular cleaning is essential for hygiene and optimal performance. Disconnect the unit from power before cleaning.
- Exterior: Wipe down the stainless steel exterior with a mild detergent and a soft cloth. Avoid abrasive cleaners.
- Interior: Clean the interior compartments and shelves with a mild, food-safe sanitizer. Rinse thoroughly and dry.
- Condenser Coil: The condenser coil should be cleaned regularly (monthly or quarterly depending on environment) to ensure efficient operation. A dirty coil can lead to increased energy consumption and reduced cooling performance. Use a stiff brush or vacuum cleaner to remove dust and debris.
Defrost System
This unit features an automatic defrost system, minimizing the need for manual defrosting. During the defrost cycle, the evaporator coil is warmed to melt any accumulated ice. The melted water drains into an evaporation pan.
Troubleshooting
Before contacting service, review the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not cooling | Power supply issue, thermostat setting, dirty condenser coil, door left open | Check power connection, adjust thermostat, clean condenser, ensure doors are closed |
| Excessive noise | Loose components, fan obstruction, unit not level | Inspect for loose parts, clear fan area, level the unit |
| Water on floor | Clogged drain line, defrost pan overflow | Clear drain line, ensure defrost pan is correctly positioned |
If the problem persists after attempting these solutions, contact qualified service personnel.
Specifications
| Feature | Detail |
|---|---|
| Model Number | C-SP60-16-HC |
| Brand | Migali |
| Product Dimensions (W x D x H) | 60.25" x 30" x 44.25" |
| Capacity | 20 Cubic Feet |
| Number of Doors | 3 |
| Defrost System | Automatic |
| Refrigerant | R290 |
| Installation Type | Freestanding |
| Electrical Connection | Nema 5-15P |

Image: Migali C-SP60-16-HC sandwich prep table with key dimensions (width, depth, height) indicated.
Warranty and Support
Migali stands behind its products with a comprehensive warranty:
- Compressor: 5-year warranty
- Parts & Labor: 2-year warranty
For technical assistance, warranty claims, or to locate authorized service providers, please contact Migali customer support. Retain your proof of purchase for warranty validation.

Image: Migali sandwich prep table with overlays indicating 5-year compressor warranty and 2-year parts & labor warranty.
Environmental Information
This Migali unit utilizes R290 refrigerant, chosen for its environmental benefits and superior cooling performance.
- High Energy Efficiency: R290 offers excellent thermodynamic properties, contributing to lower energy consumption and operating costs compared to traditional refrigerants.
- Environmentally Friendly: With an extremely low Global Warming Potential (GWP of only 3) and zero Ozone Depletion Potential (ODP), R290 is one of the most eco-friendly refrigerants available.
- Compliance & Future-Proofing: As many synthetic refrigerants are being phased out due to environmental regulations, R290 ensures compliance and long-term sustainability.
- Superior Cooling Performance: R290 delivers strong, reliable cooling capacity with quick pull-down times, ideal for commercial kitchen environments.

Image: Infographic detailing the benefits of R290 refrigerant, including energy efficiency, environmental friendliness, compliance, and superior cooling performance.