1. Product Overview

The RAVEN 115-0171-085 SCS 440/450 Console Cable is designed to provide a reliable connection for SCS 440 and SCS 450 consoles in agricultural and industrial machinery applications. This 10-foot console harness facilitates communication between system components, ensuring proper functionality.

What's in the Box:

  • One (1) RAVEN 115-0171-085 SCS 440/450 Console Cable (10' Console Harness)
RAVEN 115-0171-085 SCS 440/450 Console Cable, coiled

Figure 1: The RAVEN 115-0171-085 SCS 440/450 Console Cable, shown coiled with various connectors.

2. Setup and Installation

This section provides general guidelines for installing the RAVEN 115-0171-085 Console Cable. Always refer to the specific installation instructions for your SCS 440 or SCS 450 console and associated equipment.

  1. Power Off: Ensure all connected equipment, including the console and any power sources, are completely powered off before beginning installation.
  2. Identify Ports: Locate the appropriate console connection ports on your SCS 440 or SCS 450 unit and the corresponding ports on the equipment to be connected.
  3. Connect Cable: Carefully align the connectors on the 115-0171-085 cable with the ports on your console and equipment. Push firmly until the connectors are securely seated. Avoid forcing connections.
  4. Secure Connections: If connectors have locking mechanisms (e.g., screw collars, clips), ensure they are engaged to prevent accidental disconnection.
  5. Cable Routing: Route the cable away from moving parts, heat sources, and areas where it could be pinched or damaged. Use cable ties or clamps as necessary to secure the cable path.
Close-up of RAVEN console cable connectors

Figure 2: Close-up view of the multi-pin connectors on the RAVEN console cable, showing the connection points.

3. Operation

Once the RAVEN 115-0171-085 Console Cable is securely installed, the connected SCS 440 or SCS 450 console can be powered on and operated according to its specific user manual. The cable acts as a passive conduit for data and power, enabling the console to function as intended.

  • Ensure all connections are firm before powering on the system.
  • Monitor the console for proper initialization and communication with connected devices.
  • Refer to your SCS 440/450 console's manual for detailed operational procedures.

4. Maintenance

Proper maintenance of the console cable ensures longevity and reliable performance.

  • Regular Inspection: Periodically inspect the entire length of the cable for any signs of wear, cuts, abrasions, or damage to the outer jacket. Check connectors for bent pins, corrosion, or loose housings.
  • Cleaning: Keep connectors clean and free of dirt, dust, and moisture. Use a soft, dry cloth to wipe down the cable. For connectors, a specialized electronic contact cleaner may be used, ensuring it is safe for the materials.
  • Storage: When not in use, store the cable in a clean, dry environment, away from extreme temperatures and direct sunlight. Coil the cable loosely to prevent kinks or stress on the conductors.
  • Avoid Stress: Do not pull on the cable to disconnect it; always grasp the connector housing. Avoid sharp bends or excessive tension on the cable.

5. Troubleshooting

If you experience issues with your SCS 440/450 console after installing the RAVEN 115-0171-085 Console Cable, consider the following troubleshooting steps:

  • Check Connections: Ensure all cable connectors are fully seated and securely locked into their respective ports on both the console and the connected equipment.
  • Power Cycle: Power off all connected devices, wait a few moments, and then power them back on in the recommended sequence (e.g., equipment first, then console).
  • Inspect Cable: Visually inspect the cable for any obvious damage (cuts, severe kinks, crushed sections). A damaged cable may need replacement.
  • Consult Console Manual: Refer to the user manual for your SCS 440 or SCS 450 console for specific diagnostic procedures and error codes.
  • Test with Another Cable (if available): If possible, test the system with a known working cable to rule out the cable as the source of the problem.

6. Specifications

Product NameRAVEN 115-0171-085 SCS 440/450 Console Cable
Model Number115-0171-085
BrandRAVEN
Cable Length10 feet (approximate)
CompatibilitySCS 440 and SCS 450 Consoles
Package Dimensions10 x 10 x 2 inches
Item Weight2.95 Pounds
ASINB076HSY9PV
Date First AvailableOctober 17, 2017
Close-up of RAVEN console cable product label

Figure 3: Product label on the RAVEN console cable, showing part number (P/N: 1150171085), serial number (S/N: 64941), ISS: 04/22, REV: B, and additional identifier 8262435.

7. Warranty and Support

For information regarding warranty coverage, technical support, or service for your RAVEN 115-0171-085 SCS 440/450 Console Cable, please contact RAVEN customer service directly or visit their official website. Ensure you have your product model number (115-0171-085) and any purchase details available when seeking support.

You can find more information and contact details by visiting the RAVEN Store on Amazon.

Related Documents - 115-0171-085

Preview Raven Cable Wiring Diagrams and Specifications
Comprehensive guide to Raven Industries Flow Control Division's cable wiring diagrams, connectors, and repair procedures for agricultural equipment. Includes part numbers and specifications.
Preview GVM Predator and Prowler CAN AccuBoom Installation Manual
This manual provides instructions for installing the Raven AccuBoom system on GVM Predator and Prowler sprayers. It covers component identification, installation steps, and system troubleshooting.
Preview Raven 1254 Series Rogator CAN AccuBoom Installation and Operation Manual
This manual provides instructions for the installation and operation of the Raven 1254 Series Rogator CAN AccuBoom system. It covers component identification, installation procedures, and troubleshooting.
Preview Raven RCM - Sprayer & Hawkeye® 2 Calibration and Operation Manual
Comprehensive guide for the Raven RCM - Sprayer system with Hawkeye® 2 nozzle control technology. Covers calibration, setup, operation, and troubleshooting for agricultural spraying applications.
Preview Raven UHarvest™ Pro Operation Manual
Comprehensive guide to operating the Raven UHarvest™ Pro grain cart data management system, covering setup, data monitoring, and troubleshooting for agricultural harvest operations.
Preview Raven QuickTrax Steering Position Sensor (SPS) Kit Installation Manual
This installation manual provides detailed instructions for fitting the Raven QuickTrax Steering Position Sensor (SPS) Kit to a wide range of agricultural vehicles, including tractors, combines, and sprayers. It lists compatible models and outlines the installation process for enhanced GPS-guided steering.