ANENG AN8008

ANENG AN8008 True RMS Digital Multimeter User Manual

Model: AN8008

1. Introduction

This manual provides instructions for the safe and effective operation of the ANENG AN8008 True RMS Digital Multimeter. This compact and versatile instrument is designed for measuring AC/DC voltage, AC/DC current, resistance, capacitance, frequency, duty cycle, diode, and continuity, and also features a square wave output. Please read this manual thoroughly before use and retain it for future reference.

ANENG AN8008 Digital Multimeter with connected test leads

Figure 1: ANENG AN8008 Digital Multimeter with connected test leads. This image displays the ANENG AN8008 True RMS Digital Multimeter, featuring its large LCD screen, rotary dial for function selection, and input jacks. Red and black test leads are connected to the appropriate terminals, ready for measurement.

2. Safety Information

To ensure safe operation, observe the following safety precautions:

  • Always ensure the multimeter is set to the correct function and range before making any measurements.
  • Do not exceed the maximum input values specified for each range.
  • Exercise extreme caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
  • Inspect test leads for damage before each use. Do not use if insulation is compromised.
  • Ensure the battery compartment is securely closed before operation.
  • Do not operate the meter if it appears damaged or is not functioning properly.
  • Always disconnect power to the circuit and discharge high-voltage capacitors before measuring resistance, continuity, diodes, or capacitance.
  • Replace batteries promptly when the low battery indicator appears to maintain measurement accuracy.

3. Product Overview

The ANENG AN8008 is a compact, high-performance digital multimeter featuring a 9999-count display and True RMS measurement capability. Key features include:

  • Display: Large LCD with 9999 counts and backlight for clear visibility.
  • Ranging: Automatic and manual range selection.
  • Protection: 550V protection in Resistance, Capacitance, and Frequency ranges.
  • Measurements: AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode, and Continuity.
  • Special Functions: True RMS, Data Hold, Relative Measurement, Polarity Identification, Low Voltage Indication, Square Wave Output.
  • Current Measurement: High current (up to 9.999A) and low current measurement capabilities.
  • Power Management: Auto power off feature to conserve battery life.
ANENG AN8008 Multimeter package contents: device, leads, manual, and pouch

Figure 2: ANENG AN8008 Multimeter with accessories. This image illustrates the complete package contents of the ANENG AN8008, including the digital multimeter unit, a set of red and black test leads, the user manual, and a grey drawstring storage pouch for protection and portability.

4. Setup

4.1 Battery Installation

The ANENG AN8008 requires two 1.5V AAA batteries (not included) for operation.

  1. Ensure the multimeter is turned OFF.
  2. Locate the battery compartment cover on the back of the unit.
  3. Use a screwdriver to remove the screw securing the battery cover.
  4. Carefully remove the cover.
  5. Insert two 1.5V AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  6. Replace the battery cover and secure it with the screw.
Rear view of ANENG AN8008 Multimeter showing battery compartment and kickstand

Figure 3: Rear view of ANENG AN8008 showing battery compartment. A view of the back of the ANENG AN8008 multimeter, highlighting the removable battery cover for two AAA batteries and the integrated kickstand for convenient hands-free operation.

4.2 Connecting Test Leads

The multimeter comes with a set of red and black test leads. The red lead is for positive (+) connections, and the black lead is for negative (-) or common (COM) connections.

  • Insert the black test lead into the COM (Common) input jack.
  • For voltage, resistance, frequency, capacitance, diode, and continuity measurements, insert the red test lead into the VΩHz input jack.
  • For current measurements (mA or A), insert the red test lead into the appropriate mA or A input jack.
ANENG AN8008 Multimeter with a variety of test lead accessories

Figure 4: ANENG AN8008 Multimeter with various test lead accessories. The ANENG AN8008 multimeter is shown alongside a comprehensive set of test lead accessories, including different probe tips, alligator clips, and spade connectors, enhancing its versatility for various electrical testing scenarios.

Close-up of interchangeable test lead tips and alligator clips

Figure 5: Close-up of interchangeable test lead accessories. This close-up shows the various interchangeable tips and alligator clips provided with the multimeter, designed to connect to the test leads for different measurement applications.

5. Operating Instructions

The ANENG AN8008 features a rotary switch to select the desired measurement function. Use the 'RANGE' button for manual range selection and 'SEL/HOLD' for function selection within a combined rotary switch position or to hold the current reading.

5.1 DC Voltage Measurement (V–)

  1. Set the rotary switch to the V– position.
  2. Connect the red test lead to the positive (+) side of the circuit and the black test lead to the negative (-) side.
  3. Read the voltage value on the display.

5.2 AC Voltage Measurement (V∼)

  1. Set the rotary switch to the V∼ position.
  2. Connect the test leads across the circuit or component to be measured.
  3. Read the voltage value on the display.

5.3 DC Current Measurement (A– / mA– / µA–)

  1. Turn off power to the circuit.
  2. Set the rotary switch to the appropriate A–, mA–, or µA– position.
  3. Insert the red test lead into the A or mA input jack, and the black lead into the COM jack.
  4. Break the circuit and connect the multimeter in series with the load.
  5. Apply power to the circuit.
  6. Read the current value on the display.
  7. Turn off power and disconnect the multimeter before restoring the circuit.

5.4 AC Current Measurement (A∼ / mA∼ / µA∼)

Follow the same procedure as DC Current Measurement, but select the appropriate A∼, mA∼, or µA∼ position on the rotary switch.

5.5 Resistance Measurement (Ω)

  1. Turn off power to the circuit and discharge any capacitors.
  2. Set the rotary switch to the Ω position.
  3. Connect the test leads across the component to be measured.
  4. Read the resistance value on the display.

5.6 Capacitance Measurement (F)

  1. Turn off power to the circuit and fully discharge the capacitor before measurement.
  2. Set the rotary switch to the F position.
  3. Connect the test leads across the capacitor.
  4. Read the capacitance value on the display.

5.7 Frequency and Duty Cycle Measurement (Hz / %)

  1. Set the rotary switch to the Hz position.
  2. Connect the test leads across the signal source.
  3. The display will show the frequency. Press the 'SEL/HOLD' button to toggle to duty cycle measurement.

5.8 Diode Test (→|–)

  1. Turn off power to the circuit and discharge any capacitors.
  2. Set the rotary switch to the →|– position.
  3. Connect the red test lead to the anode and the black test lead to the cathode of the diode.
  4. The display will show the forward voltage drop. Reverse the leads to check for open circuit (OL) for a good diode.

5.9 Continuity Test (♫)

  1. Turn off power to the circuit.
  2. Set the rotary switch to the ♫ position.
  3. Connect the test leads across the component or circuit path.
  4. If the resistance is below approximately 50Ω, the buzzer will sound, indicating continuity.

5.10 Square Wave Output

  1. Set the rotary switch to the Square Wave Output position.
  2. The multimeter can output a square wave at various frequencies (50Hz to 5000Hz).
  3. Connect the test leads to the output terminals to utilize this function.

6. Maintenance

6.1 Cleaning

Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.

6.2 Battery Replacement

When the low battery indicator appears on the display, replace the batteries as described in Section 4.1. Always use two new 1.5V AAA batteries.

6.3 Fuse Replacement

If the current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.

7. Troubleshooting

  • No display or dim display: Check battery installation and charge. Replace batteries if necessary.
  • "OL" (Overload) displayed: The measured value exceeds the selected range. Switch to a higher range or ensure the input is within the meter's capabilities.
  • Incorrect readings: Verify test lead connections, ensure the correct function and range are selected, and check battery condition.
  • No continuity beep: Ensure the meter is in continuity mode and the resistance is below the threshold (approx. 50Ω).

8. Specifications

8.1 Electrical Specifications

Table detailing electrical specifications of the ANENG AN8008 Multimeter

Figure 6: Electrical Specifications Table. A detailed table outlining the electrical specifications of the ANENG AN8008, including ranges, resolutions, and accuracies for DC Voltage, AC Voltage, DC Current, AC Current, and Resistance measurements.

Electrical Measurement Ranges and Accuracy
FunctionRangeResolutionAccuracyMAX. Value
DC Voltage (V)9.999mV / 99.99mV / 999.9mV0.001mV / 0.01mV / 0.1mV±(0.5%+3)999.9V
9.999V / 99.99V / 999.9V0.001V / 0.01V / 0.1V
AC Voltage (V)9.999mV / 99.99mV / 999.9mV0.001mV / 0.01mV / 0.1mV±(1.0%+3) (40Hz-1kHz)750V
9.999V / 99.99V / 750.0V0.001V / 0.01V / 0.1V
DC Current (A)99.99µA / 999.9µA0.01µA / 0.1µA±(0.8%+3)9.999A
999.9mA / 9.999A0.1mA / 0.001A±(1.0%+3)
AC Current (A)99.99µA / 999.9µA0.01µA / 0.1µA±(1.0%+3) (40Hz-1kHz)9.999A
999.9mA / 9.999A0.1mA / 0.001A±(1.2%+3) (40Hz-1kHz)
Resistance (Ω)99.99Ω0.01Ω±(1.0%+3)9.999MΩ
999.9Ω / 9.999KΩ / 99.99KΩ / 999.9KΩ0.1Ω / 0.001KΩ / 0.01KΩ / 0.1KΩ±(0.5%+3)
9.999MΩ0.001MΩ±(1.5%+3)
Capacitance (F)9.999nF0.001nF±(5.0%+20)9.999mF
99.99nF / 999.9nF / 9.999µF / 99.99µF / 999.9µF0.01nF / 0.1nF / 0.001µF / 0.01µF / 0.1µF±(2.0%+5)
9.999mF0.001mF±(5.0%+5)
Frequency (Hz)99.99Hz / 999.9Hz / 9.999kHz / 99.99kHz / 999.9kHz / 9.999MHz0.01Hz / 0.1Hz / 0.001kHz / 0.01kHz / 0.1kHz / 0.001MHz±(0.1%+2)9.999MHz
Duty Cycle (%)1% to 99%0.1%±(0.1%+2)
Square Wave Output50Hz/100Hz/200Hz/300Hz/400Hz/500Hz/600Hz/700Hz/800Hz/900Hz/1000Hz/2000Hz/3000Hz/4000Hz/5000Hz

8.2 General Specifications

Table detailing general, mechanical, environmental, and safety specifications of the ANENG AN8008 Multimeter

Figure 7: General Specifications Table. This table provides general specifications such as display counts, ranging, material, update rate, and features like True RMS and backlight. It also lists mechanical specifications (dimension, weight, battery type), environmental conditions (operating and storage temperature/humidity), and safety standards.

General, Mechanical, and Environmental Specifications
CategorySpecification
Display9999 Counts LCD
RangingAuto/Manual
MaterialABS
Update Rate3 Times/Second
True RMSYes
BacklightYes
Data HoldYes
Low Battery IndicationYes
Auto Power OffYes
Dimensionapprox. 132 x 65 x 30 mm
Net Weightapprox. 113g
Battery Type1.5V AAA batteries x 2 (Not included)
Operating Environment0~40℃, relative humidity <80%
Storage Environment-20~60℃, relative humidity <80%
Safety StandardsEN 61010-1; EN 61326-1; FCC Part 15 Subpart B

9. Warranty and Support

The ANENG AN8008 Digital Multimeter typically comes with a one-year warranty from the date of purchase. For warranty claims or technical support, please contact your retailer or the manufacturer, ANENG, directly. Keep your purchase receipt as proof of purchase.