1. Safety Information
Please read all safety instructions carefully before installing or operating your Aux ASW-12A2/FFR2 air conditioner. Keep this manual for future reference.
- Ensure the power supply matches the unit's requirements (60 Volts DC).
- Installation of this split system air conditioner should only be performed by qualified professionals.
- Do not block air inlets or outlets.
- Do not insert objects into the air conditioner.
- Disconnect power before cleaning or performing maintenance.
- Keep children away from the unit.
2. Product Overview
The Aux ASW-12A2/FFR2 is a high-efficiency air conditioner designed for cooling and dehumidification. It incorporates advanced features for user comfort and unit longevity.
Key Features
- I FEEL Technology: Intelligent remote control that senses the temperature around the user, allowing for personalized operation, temperature, and fan speed settings.
- Anti-fungus Function: Prevents the growth of fungi within the unit.
- Auto-cleaning: Automatically cleans the evaporator to prevent bacterial proliferation and remove dust particles.
- Dehumidifier: Special feature to reduce humidity in the room.
- Cooling Only: Designed for cooling functionality.
Components
The system includes an evaporator (indoor unit) and a condenser (outdoor unit), which are essential for its split system operation.

An image showing the white Aux ASW-12A2/FFR2 air conditioner unit, typically mounted on a wall, with its front panel and top vents visible.
3. Setup and Installation
Proper installation is crucial for the performance and safety of your air conditioner. It is strongly recommended that installation be carried out by a certified technician.
Unpacking
- Carefully remove the air conditioner units (evaporator and condenser) from their packaging.
- Check for any signs of damage during transit. Contact your dealer immediately if damage is found.
- Ensure all accessories, including the remote control, are present.
Installation Method
This unit is a Split System air conditioner, meaning it consists of an indoor unit (evaporator) and an outdoor unit (condenser) connected by refrigerant lines and electrical wiring. Professional installation is mandatory to ensure correct refrigerant handling, electrical connections, and optimal performance.
Electrical Requirements
The Aux ASW-12A2/FFR2 operates on a 60 Volt (DC) electrical supply. Ensure your electrical system can safely provide the necessary power. The unit is designed for a wired electrical connection. Consult with your installer regarding dedicated circuit requirements.
4. Operating Instructions
Your air conditioner is controlled via a remote control, offering various functions for your comfort.
Remote Control
The intelligent remote control is the primary interface for operating your Aux ASW-12A2/FFR2. It features I FEEL technology, which allows the unit to adjust its operation based on the temperature sensed at the remote's location, providing more precise comfort.
Basic Operation
- Power On/Off: Press the ON/OFF button to start or stop the unit.
- Mode Selection: Press the MODE button to cycle through available modes (e.g., Cool, Dehumidify).
- Temperature Adjustment: Use the TEMP UP and TEMP DOWN buttons to set your desired temperature.
- Fan Speed: Press the FAN button to adjust the fan speed (e.g., Low, Medium, High, Auto).
Special Functions
- Anti-fungus: This function activates automatically or can be manually selected (refer to remote control manual) to dry the evaporator coil after cooling operation, preventing mold and mildew growth.
- Auto-cleaning: This feature helps maintain the cleanliness of the evaporator by removing dust and preventing bacterial buildup.
- Dehumidifier: Select the dehumidifier mode to effectively reduce indoor humidity without significant temperature drops.
5. Maintenance
Regular maintenance ensures efficient operation and extends the lifespan of your air conditioner.
Filter Cleaning
- Turn off the air conditioner and disconnect it from the power supply.
- Open the front panel of the indoor unit.
- Remove the air filters.
- Clean the filters with a vacuum cleaner or wash them with lukewarm water and mild detergent. Rinse thoroughly.
- Allow filters to dry completely before reinstalling.
- Close the front panel.
Exterior Cleaning
Wipe the exterior of the indoor and outdoor units with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
Seasonal Storage (If applicable)
If the unit will not be used for an extended period, clean the filters, run the unit in fan-only mode for a few hours to dry the internal components, and then disconnect the power supply.
6. Troubleshooting
Before contacting service, refer to the following common issues and solutions:
- Unit does not turn on: Check power supply, circuit breaker, and ensure the remote control batteries are not depleted.
- Insufficient cooling: Ensure doors and windows are closed, air filters are clean, and there are no obstructions to airflow. Verify the temperature setting is appropriate.
- Unusual noises: A slight gurgling sound is normal due to refrigerant flow. Loud or persistent noises may indicate an issue requiring professional inspection.
- Water leakage: Check if the drainage hose is blocked or improperly installed.
For issues not resolved by these steps, please contact a qualified service technician.
7. Specifications
| Specification | Value |
|---|---|
| Brand | Aux |
| Model Name | ASW 12A2 |
| Model Number | ASW-12A2/FFR2 |
| Cooling Capacity | 12000 British Thermal Units |
| Special Feature | Dehumidifier |
| Product Dimensions (D x W x H) | 55prof. x 80an. x 40alt. centimeters |
| Color | azul |
| Voltage | 60 Volts (DC) |
| Noise Level | 10 Decibels |
| Power Source | Wired Electric |
| Wattage | 110 watts |
| Item Weight | 40 Kilograms |
| Annual Energy Consumption | 11.5 Watts |
| Included Elements | Evaporator and condenser |
| Manufacturer | AUX |
| ASIN | B075YGYN7D |
| Controller Type | Remote Control |
| Warranty Type | Limited |
| BEE Rating | 1 Star |
8. Warranty and Support
Warranty Information
This Aux ASW-12A2/FFR2 air conditioner comes with a limited warranty. The product warranty is valid for 30 days with the manufacturer. Please retain your proof of purchase for warranty claims.
Customer Support
For technical assistance, service requests, or warranty inquiries, please contact your authorized Aux dealer or the manufacturer's customer support. Refer to your purchase documentation for specific contact details.