Omron Healthcare MC-687

Omron Electronic Thermometer MC-687 User Manual

1. Introduction and Overview

This manual provides instructions for the safe and effective use of your Omron MC-687 Electronic Thermometer. This device is designed for accurate body temperature measurement, offering both quick predictive readings and precise actual measurements. Key features include a 15-second predictive measurement, a buzzer to indicate completion, memory for the last reading, and an automatic power-off function.

Omron MC-687 Electronic Thermometer, white, with a digital display.

Image: The Omron MC-687 Electronic Thermometer, a sleek white device with a clear digital display for temperature readings.

2. Safety Information

3. Package Contents

Verify that all items are present in the package:

Omron MC-687 Electronic Thermometer in its retail packaging.

Image: The Omron MC-687 Electronic Thermometer displayed in its retail packaging, highlighting its quick measurement feature.

4. Setup

The Omron MC-687 thermometer comes with a test battery pre-installed, making it ready for immediate use. No initial setup is typically required beyond removing it from its packaging.

4.1 Initial Check

  1. Remove the thermometer from its storage case.
  2. Press the power button. The display should light up, showing the last measured temperature or a default reading.
  3. If the display does not light up, refer to the Troubleshooting section for battery replacement instructions.

5. Operating Instructions

5.1 Taking a Measurement

  1. Press the power button to turn on the thermometer.
  2. Place the sensing tip of the thermometer firmly in the armpit (axillary measurement). Ensure good skin contact.
  3. Hold the thermometer in place. The device will begin a predictive measurement.
  4. After approximately 15 seconds, a buzzer will sound, and the predictive temperature will be displayed. This is a quick estimate of your body temperature.
  5. To obtain a more precise, actual measurement, continue holding the thermometer in place after the predictive reading. The thermometer will automatically switch to actual measurement mode.
  6. The actual measurement for axillary use typically takes about 10 minutes. A longer buzzer sound will indicate the completion of the actual measurement.
  7. Remove the thermometer and read the final temperature displayed.
  8. Press the power button to turn off the thermometer, or it will automatically power off after a period of inactivity.
Graph showing predictive vs. actual measurement times.

Image: A graph illustrating the difference between predictive (approx. 15 seconds) and actual (approx. 10 minutes) measurement times for the Omron thermometer, showing temperature rise over time to reach equilibrium.

5.2 Understanding Predictive vs. Actual Measurement

The Omron MC-687 offers two measurement modes:

Explanation of Predictive Measurement.

Image: Visual explanation of Predictive Measurement, showing how the thermometer analyzes initial temperature rise to quickly estimate the final temperature.

Explanation of Actual Measurement.

Image: Visual explanation of Actual Measurement, detailing how it measures the current temperature of the body part, requiring longer times for accuracy.

5.3 Memory Function

The thermometer automatically stores the last measured temperature. To recall the last reading, simply press the power button when the device is off. The stored temperature will be displayed briefly before the thermometer enters measurement mode.

6. Maintenance

6.1 Cleaning

After each use, clean the thermometer probe with a soft cloth dampened with alcohol or mild soap and water. Do not immerse the entire thermometer in water or use harsh chemical cleaners.

6.2 Storage

Store the thermometer in its protective case in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it out of reach of children.

Omron MC-687 Electronic Thermometer with its protective storage case.

Image: The Omron MC-687 Electronic Thermometer shown with its dedicated protective storage case, emphasizing proper storage.

6.3 Battery Replacement

When the battery indicator appears on the display, it is time to replace the battery. The thermometer uses one CR1220 alkaline button battery.

  1. Locate the battery cover on the back of the thermometer.
  2. Use a small coin or screwdriver to open the battery cover.
  3. Remove the old battery and insert a new CR1220 battery with the positive (+) side facing up.
  4. Replace the battery cover and secure it tightly.

7. Troubleshooting

If problems persist, contact Omron Healthcare customer support.

8. Specifications

ModelMC-687
Dimensions (W x L x D)20.7 mm x 136.8 mm x 12.8 mm
WeightApprox. 14g (including battery)
Measurement MethodAxillary (underarm)
Measurement TimePredictive: Approx. 15 seconds
Actual: Approx. 10 minutes
Measurement Range32.0°C to 42.0°C
Measurement Accuracy±0.1°C (between 35.0°C and 39.0°C)
Power SourceCR1220 Alkaline Button Battery x 1
FunctionsBuzzer, Last Reading Memory, Auto Power Off
MaterialsSensing part: Stainless steel, Probe: ABS
Medical Device Number229AGBZX00037000
Country of OriginChina
Included AccessoriesProtective Storage Case, Test Battery

9. Warranty and Support

For warranty information, please refer to the warranty card included with your product or visit the official Omron Healthcare website. If you require technical support, have questions about the product, or need assistance with troubleshooting, please contact Omron Healthcare customer service through their official channels.

Official Omron Healthcare Website: www.omron-healthcare.com