1. Introduction
Thank you for choosing the AIRCARE Ultrasonic Cool Mist Humidifier. This device is designed to add essential moisture to the air, helping to alleviate dry air conditions in your home or office. It features whisper-quiet operation, a multi-color LED night light, and an aroma therapy essential oil diffuser, making it a versatile addition to any room. Please read this manual thoroughly before operation to ensure safe and efficient use.
2. Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons.
- Do not operate the humidifier if the cord or plug is damaged.
- Keep the humidifier away from heat sources and direct sunlight.
- Always place the humidifier on a firm, flat, water-resistant surface.
- Do not block air vents.
- Unplug the unit before filling, cleaning, or moving.
- Do not add essential oils directly into the water tank; use the designated diffuser tray.
- Keep out of reach of children and pets.
Proposition 65 Warning: This product can expose you to chemicals including styrene which is known to the State of California to cause cancer or other reproductive harm.
3. Product Features
- Ultrasonic Cool Mist Technology: Provides fine, visible mist for comfortable humidity.
- Whisper-Quiet Operation: Ideal for bedrooms, nurseries, and offices.
- Multi-Color LED Night Light: Offers ambient lighting with changing colors.
- Aroma Therapy Essential Oil Diffuser: Integrated tray for use with essential oils (oils sold separately).
- Filterless Design: No filters to replace, simplifying maintenance.
- Auto Shut-off: Automatically turns off when water level is low for safety.
- Coverage Area: Effective in spaces up to 360 square feet.
- Extended Run Time: Operates for up to 12 hours on a single fill.

Figure 1: AIRCARE AURORAMINI Humidifier with key specifications.
4. Package Contents
Your AIRCARE Ultrasonic Cool Mist Humidifier package includes:
- 1 x AIRCARE Ultrasonic Cool Mist Humidifier Unit
5. Setup
5.1 Placement
Place the humidifier on a flat, stable, and water-resistant surface at least 6 inches away from walls and furniture. Ensure the mist outlet is not directed at walls or furniture to prevent moisture damage.

Figure 2: Proper placement of the humidifier on a nightstand.
5.2 Filling the Water Tank
- Unplug the humidifier from the power outlet.
- Carefully lift the water tank from the base.
- Unscrew the water tank cap.
- Fill the tank with clean, cool tap water. Distilled or demineralized water is recommended to prevent mineral buildup and white dust.
- Securely screw the cap back onto the water tank.
- Place the filled water tank back onto the humidifier base, ensuring it is seated correctly.
5.3 Adding Essential Oils (Optional)
To use the aroma therapy feature:
- Locate the essential oil diffuser tray on the side of the humidifier base.
- Pull out the tray.
- Add a few drops of your preferred essential oil onto the aroma pad within the tray.
- Slide the tray back into its slot.

Figure 3: Essential oil diffuser tray.
6. Operating Instructions
6.1 Power On/Off and Mist Control
- Plug the humidifier into a standard electrical outlet.
- Turn the mist control knob clockwise to turn the unit on and adjust the mist output from low to high. The power indicator light will illuminate green.
- Turn the mist control knob counter-clockwise until it clicks to turn the unit off.
6.2 LED Night Light Operation
Press the 'LED' button located next to the mist control knob to cycle through the multi-color light options or turn the light off.

Figure 4: Mist control knob and LED light button.
7. Maintenance
Regular cleaning is essential for optimal performance and hygiene.
7.1 Daily Maintenance
- Empty the water tank and base daily.
- Rinse the tank and base with fresh water.
- Wipe down all surfaces with a soft, damp cloth.
7.2 Weekly Maintenance
- Unplug the unit and disassemble the water tank from the base.
- Clean the water tank and base with a mixture of white vinegar and water (1:1 ratio) to remove mineral deposits. Let it soak for 20-30 minutes.
- Use a soft brush or cloth to gently clean the ultrasonic transducer (the small disc in the base).
- Rinse all components thoroughly with clean water until the vinegar smell is gone.
- Dry all parts completely before reassembling or storing.
7.3 Aroma Pad Maintenance
The aroma pad in the diffuser tray should be cleaned or replaced periodically to maintain effective scent diffusion. Rinse the pad with water and allow it to air dry, or replace with a new pad if heavily soiled or worn.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No mist or low mist output | Low water level Mineral buildup on transducer Unit not properly assembled | Refill water tank Clean transducer as per maintenance Ensure tank is seated correctly |
| Unusual noise | Unit not on a flat surface Water level too low | Place on a stable, flat surface Refill water tank |
| LED light not working | Light function off Power issue | Press LED button to turn on Check power connection |
| White dust around humidifier | Hard water used | Use distilled or demineralized water |
9. Specifications
- Model Name: Ultrasonic Humidifier
- Model Number: AUV10AWHT
- Brand: AIRCARE
- Color: White
- Operation Mode: Ultrasonic
- Capacity: 0.33 Gallons
- Run Time: Up to 12 hours
- Coverage Area: Up to 360 Square Feet
- Special Features: Aroma Diffuser, Night Light, Quiet, Auto Shut-off
- Filter Type: Filterless
- Product Dimensions: 6.5"D x 6.3"W x 9.5"H
- Item Weight: 1.5 Pounds
- Voltage: 120 Volts
- Room Type: Baby, Bedroom, Nursery, Office

Figure 5: Product Dimensions.
10. Warranty and Support
For warranty information or technical support, please refer to the warranty card included with your product or visit the official AIRCARE website. Keep your purchase receipt as proof of purchase.