Broan-NuTone ERV200TE

Download PDF
Contents

Broan ERV200TE Energy Recovery Ventilator

Model: ERV200TE

User Manual

1. Introduction

Thank you for choosing the Broan ERV200TE Energy Recovery Ventilator. This manual provides essential information for the safe installation, operation, and maintenance of your unit. Please read this manual thoroughly before installation or use to ensure proper function and to prevent potential hazards.

The Broan ERV200TE is part of the HE Series, designed to provide optimal whole-house ventilation for energy-efficient homes. It recovers heat and manages humidity, contributing to improved indoor air quality and comfort.

2. Safety Information

WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:

  • Read all instructions before installing or operating this appliance.
  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Do not use this unit with any solid-state speed control device.
  • This unit is approved for installation in unheated spaces, but proper insulation of ducts is crucial to prevent condensation.
  • Always disconnect power to the unit before servicing or cleaning.
  • Ensure all ductwork is properly sealed and insulated to prevent energy loss and condensation.

3. Setup and Installation

The Broan ERV200TE is designed for top-port installation, meaning all air connections are made from the top of the unit. Professional installation is highly recommended to ensure compliance with local building codes and optimal performance.

3.1 Unit Placement

Select a location that allows for easy access for maintenance, such as a utility room, basement, or attic. Ensure there is sufficient clearance around the unit for airflow and servicing.

3.2 Ducting Connections

The unit features oval ports designed to fit 6-inch round ductwork. Use appropriate adapters and seal all connections thoroughly to prevent air leakage. Insulate all ductwork, especially in unheated spaces, to prevent heat loss and condensation.

Broan ERV200TE Energy Recovery Ventilator unit with top ports and blue side panel

This image displays the Broan ERV200TE Energy Recovery Ventilator. The unit is dark gray with a prominent blue panel on the right side, labeled 'HE Series' vertically. Four circular ports are visible on the top of the unit, indicating its top-port configuration. The Broan logo is centered on the front panel.

3.3 Electrical Connections

The ERV200TE operates on 120 Volts. All electrical wiring must be performed by a licensed electrician in accordance with national and local electrical codes.

4. Operating Instructions

The Broan ERV200TE is designed for continuous operation to maintain optimal indoor air quality. The unit's ECM motors provide significant electrical consumption savings compared to standard motors.

4.1 Airflow Control

The unit operates within a 50–250 CFM (Cubic Feet Per Minute) range, which can be adjusted to suit the size of your home and ventilation needs. Refer to your installer or the separate control manual for specific airflow adjustment procedures.

4.2 Anti-freeze Setting

The ERV200TE includes an anti-freeze setting to prevent ice buildup in the core during cold weather conditions. This feature operates automatically to ensure continuous performance.

4.3 Filtration

The unit comes with MERV 6 filtration. Optional HEPA filtration is available for select models, capable of capturing 99.97% of allergens and microscopic particles, which may help reduce allergy or respiratory symptoms.

5. Maintenance

Regular maintenance is crucial for the efficient and long-lasting operation of your ERV unit.

5.1 Filter Replacement/Cleaning

The MERV 6 filters should be inspected every 3 months and cleaned or replaced as needed. If using optional HEPA filters, follow the manufacturer's recommendations for replacement intervals. Dirty filters can restrict airflow and reduce efficiency.

5.2 Core Cleaning

The energy recovery core should be cleaned annually or as recommended by a qualified technician. Refer to the detailed cleaning instructions in the full installation guide for proper removal and cleaning procedures.

5.3 Drain Pan Inspection

Periodically inspect the drain pan and drain line for any blockages or standing water. Ensure the drain line is clear to allow proper condensate removal.

6. Troubleshooting

If your Broan ERV200TE is not operating as expected, consult the following common issues before contacting customer support.

ProblemPossible CauseSolution
Unit not operatingNo power supply
Circuit breaker tripped
Check power connection
Reset circuit breaker
Reduced airflowDirty filters
Blocked ductwork
Clean or replace filters
Inspect and clear ductwork
Unusual noiseLoose components
Motor issue
Check for loose parts
Contact qualified technician
Condensation around unitImproperly insulated ducts
Blocked drain line
Ensure ducts are insulated
Clear drain line

If the problem persists after attempting these solutions, please contact a qualified HVAC technician or Broan-NuTone customer support.

7. Specifications

FeatureSpecification
Model NumberERV200TE
BrandBroan-NuTone
Airflow Capacity200 CFM (Cubic Feet Per Minute)
Voltage120 Volts
Item Weight96 Pounds
Product Dimensions (L x W x H)20 x 32 x 31 inches
Ports LocationTop Ports
Port SizeOval, fits 6" round duct
Filtration LevelMERV 6 (Optional HEPA available)
Apparent Sensible Efficiency (32°F)86%
Sensible Recovery Efficiency (-13°F)65%
Sound Level0 Sones
ManufacturerBroan
UPC026715242672

8. Warranty and Support

For detailed warranty information, please refer to the documentation included with your Broan ERV200TE unit or visit the official Broan-NuTone website. Warranty terms and conditions may vary.

If you require technical assistance, replacement parts, or have questions not covered in this manual, please contact Broan-NuTone customer support. You can find contact information on their official website or through the Broan-NuTone store on Amazon: Visit the Broan-NuTone Store.

© 2025 Broan-NuTone. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.