Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Goodman 8kW Electric Heat Kit, model HKSC08XC. This kit is designed to enhance the heating capacity of select Goodman air handler systems. Please read this manual thoroughly before proceeding with installation or operation.

Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read these instructions thoroughly before installing or servicing this equipment.

Product Overview

The Goodman 8kW Electric Heat Kit (HKSC08XC) is designed to provide supplemental heating for compatible Goodman air handlers. It delivers 27,297 BTU of heating per hour. Key features include:

Goodman 8kW Electric Heat Kit (HKSC08XC) with heating elements and circuit board

Image 1: Goodman 8kW Electric Heat Kit (HKSC08XC). This image shows the heating elements and the integrated circuit board, ready for installation into a compatible air handler.

Product label for Goodman 8kW Electric Heat Kit showing model HKSC08XCBA and specifications

Image 2: Product label for the Goodman 8kW Electric Heat Kit. The label displays important information including the model number HKSC08XCBA, power supply requirements (208-240 Volts, 1 Phase, 50/60 Hz), and 8.0 kW @ 240 Volts rating.

Setup and Installation

The Goodman 8kW Electric Heat Kit is designed for straightforward installation into compatible Goodman air handlers. Professional installation is recommended to ensure proper function and safety.

  1. Preparation: Ensure the air handler is powered off at the main electrical panel. Verify compatibility of the heat kit with your specific air handler model.
  2. Access: Open the access panel on the air handler where the heat kit is to be installed.
  3. Mounting: Carefully slide the heat kit into the designated slot within the air handler. Secure it using the provided fasteners, ensuring a snug fit.
  4. Electrical Connection: Connect the plug-in wiring harness from the heat kit to the corresponding receptacle in the air handler. Ensure all connections are secure.
  5. Circuit Breaker: The heat kit includes an integrated circuit breaker. Ensure it is properly seated and connected within the air handler's electrical compartment.
  6. Closure: Close and secure the air handler access panel.
  7. Power Restoration: Restore electrical power to the air handler at the main electrical panel.

For a visual guide on installing a similar Goodman electric heat kit, please refer to the video below. Note that the video demonstrates a 10kW kit, but the general installation steps are comparable.

Video 1: Installation guide for a Goodman 10 KW Electric Heat Kit. This video provides a visual walkthrough of the installation process for a Goodman electric heat kit, which is similar to the HKSC08XC model. It covers steps such as preparing the air handler, mounting the kit, and making electrical connections.

Operating Instructions

Once installed, the 8kW Electric Heat Kit operates in conjunction with your Goodman air handler and thermostat. The heat kit will activate automatically when supplemental heating is required, typically when the ambient temperature drops below the thermostat's set point and the primary heating source (e.g., heat pump) cannot meet the demand alone.

Maintenance

Regular maintenance ensures the longevity and efficient operation of your heat kit and air handler system. Always disconnect power before performing any maintenance.

Troubleshooting

If you encounter issues with your Goodman 8kW Electric Heat Kit, refer to the following common troubleshooting steps. For complex issues, contact a qualified HVAC technician.

Problem Possible Cause Solution
No Heat Output
  • Thermostat setting incorrect.
  • Power supply interrupted.
  • Heat kit circuit breaker tripped.
  • Faulty heating element.
  • Verify thermostat is set to "Heat" and desired temperature.
  • Check main electrical panel for tripped breakers.
  • Reset the heat kit's integrated circuit breaker.
  • Contact a qualified technician for diagnosis and repair.
Insufficient Heat
  • Dirty air filter.
  • Airflow obstruction.
  • Undersized heat kit for space.
  • Replace or clean air filter.
  • Ensure vents are open and not blocked.
  • Consult with an HVAC professional to assess heating requirements.
Unusual Noises
  • Loose components.
  • Motor issues (air handler).
  • Inspect for loose parts and secure them (after disconnecting power).
  • Contact a qualified technician.

Specifications

Feature Detail
Model Number HKSC08XC
Heating Capacity 8 kW (27,297 BTU/hr)
Voltage 208-240 Volts
Phase Single Phase
Frequency 50/60 Hz
Product Dimensions 8.5 x 12.5 x 16 inches
Item Weight 0.01 ounces
Manufacturer Goodman

Warranty Information

Goodman products are typically covered by a limited warranty. Specific warranty terms and conditions may vary. Please refer to the warranty documentation included with your air handler or visit the official Goodman website for detailed information regarding your specific product's warranty coverage. Keep your proof of purchase for warranty claims.

Support and Contact

For technical assistance, troubleshooting beyond this manual, or to locate a qualified service technician, please contact Goodman customer support or visit their official website. When contacting support, have your model number (HKSC08XC) and serial number ready.

Goodman Manufacturing Company, L.P.
5151 San Felipe, Ste 500
Houston, Texas 77056

Note: Contact information is subject to change. Please refer to the official Goodman website for the most current details.

Related Documents - HKSC08XC

Preview HKS & HKTS Electric Heat Kit Installation Instructions
Installation instructions for HKS and HKTS Electric Heat Kits, covering safety precautions, shipping inspection, standard air handler installation, electrical connections, and start-up procedures. Includes detailed diagrams and warnings.
Preview HKS & HKTS Electric Heat Kit Installation Instructions
Comprehensive installation guide for HKS and HKTS electric heat kits, covering safety precautions, shipping inspection, standard air handler installation, electrical connections, and start-up procedures. Includes important warnings and model compatibility information.
Preview Goodman CPLE Series 10 SEER Split System Heat Pump Product Specifications
Detailed product specifications for the Goodman CPLE Series 10 SEER Split System Heat Pump. This document includes comprehensive information on standard features, cabinet construction, air handler and coil compatibilities, available accessories, detailed specifications, electrical data, unit dimensions, and extensive cooling and heating performance ratings for models ranging from 1½ to 5 Ton.
Preview Goodman Light Commercial 3-6 Ton Belt Drive Pkg Heat Pumps Repair Parts Catalog
Comprehensive repair parts catalog for Goodman Light Commercial 3-6 Ton Belt Drive Packaged Heat Pumps (RP-633). Details components, part numbers, and model applicability for HVAC technicians, covering various assemblies like top panel, cabinet, condenser/evaporator coils, blower, and control box.
Preview Goodman & Amana R-410A Split System Service Instructions
Comprehensive service manual for Goodman and Amana R-410A split system heat pumps, condensing units, air handlers, and coils, detailing product identification, troubleshooting, and servicing procedures for HVAC technicians.
Preview Goodman GSZ13/SSZ14 Split System Heat Pumps R-410A Service Instructions
Service manual for Goodman GSZ13 and SSZ14 split system heat pumps using R-410A refrigerant. Includes detailed information on blowers, coils, accessories, safety, operation, and troubleshooting for HVAC professionals.