PCE Instruments PCE-170 A

PCE Instruments PCE-170 A Light Meter User Manual

Model: PCE-170 A

1. Introduction

This manual provides comprehensive instructions for the safe and effective use of the PCE Instruments PCE-170 A Light Meter. This device is designed for measuring illuminance (lux or foot-candles) in various environments, such as offices, factories, and outdoor settings. It features a wide measurement range, fast response time, and a compact design for ease of use.

Please read this manual thoroughly before operating the device and retain it for future reference.

2. Safety Information

Observe the following safety precautions to prevent injury and avoid damage to the device:

3. Product Overview

The PCE-170 A Light Meter consists of a main unit with a display and control buttons, and an integrated light sensor.

PCE-170 A Light Meter front view

Figure 1: Front view of the PCE-170 A Light Meter, showing the display, control buttons, and light sensor at the top.

3.1 Components

Close-up of PCE-170 A Light Meter display

Figure 2: Close-up view of the LCD display, showing a reading of "534 lx" and "AUTO RANGE 4 000".

Close-up of PCE-170 A Light Meter sensor

Figure 3: Detailed view of the light sensor at the top of the device, with its protective cap removed.

4. Setup

4.1 Battery Installation

  1. Locate the battery compartment cover on the back of the device.
  2. Slide the cover open or unscrew it, depending on the model.
  3. Insert one 9V battery, observing the correct polarity (+/-).
  4. Replace the battery compartment cover securely.
PCE-170 A Light Meter with carrying case and 9V battery

Figure 4: The PCE-170 A Light Meter shown with its carrying case and the included 9V battery, ready for installation.

4.2 Initial Power-On

Press the Power button to turn on the device. The display will illuminate and show a reading. If the battery symbol appears, replace the battery.

5. Operating Instructions

5.1 Taking a Measurement

  1. Turn on the device using the Power button.
  2. Ensure the light sensor is clean and unobstructed.
  3. Position the light sensor at the location where illuminance is to be measured. Ensure the sensor is facing the light source directly for accurate readings.
  4. The current illuminance value will be displayed on the LCD.
Person using PCE-170 A Light Meter in an office setting

Figure 5: A user measuring light levels in an office environment with the PCE-170 A Light Meter.

5.2 Changing Measurement Units (fc/lx)

Press the fc/lx button to toggle between foot-candles (fc) and lux (lx) units. The selected unit will be indicated on the display.

5.3 HOLD Function

Press the HOLD button to freeze the current reading on the display. Press it again to release the hold and resume live measurements.

5.4 Zero Adjustment (CAL)

To perform a zero adjustment:

  1. Place the light sensor in a completely dark environment (e.g., cover it with the protective cap or place it in a dark box).
  2. Press the CAL button. The display should show "0.00" or a value very close to zero.
  3. If the display does not show zero, repeat the process.

5.5 Range Selection

The device typically operates in auto-ranging mode. To manually select a range or cycle through available ranges, press the RANGE button. The display will indicate the active range. Press and hold the RANGE button to return to auto-ranging mode.

5.6 Min/Max Function (Power-Up Option)

The PCE-170 A supports Min/Max recording. To activate this feature, refer to the power-up options indicated on the device label (e.g., press and hold a specific button during power-on). This function records the minimum and maximum illuminance values detected during a measurement session.

6. Maintenance

6.1 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Keep the light sensor clean and free of dust or smudges, as this can affect measurement accuracy.

6.2 Storage

When not in use, store the PCE-170 A Light Meter in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove the battery if storing for extended periods.

7. Troubleshooting

ProblemPossible CauseSolution
Device does not turn on.Dead or incorrectly installed battery.Check battery polarity or replace with a new 9V battery.
Display shows "OL" (Overload).Light intensity exceeds the current measurement range.Switch to a higher measurement range using the RANGE button, or move to a less intensely lit area.
Inaccurate readings.Dirty sensor, incorrect zero adjustment, or sensor not facing light source correctly.Clean the sensor, perform zero adjustment in darkness, and ensure the sensor is properly oriented.
Display is blank or flickering.Low battery.Replace the 9V battery.

8. Specifications

ParameterValue
Measurement Ranges0.00 ... 40,000 lux / 0.000 ... 4000 fc
Resolution0.01 lux / 0.001 fc
Accuracy±3% of measurement value + 5 digits
Overload Indicator"OL"
Measurement RateEvery 2 seconds
Operating Temperature0 ... 40°C / 32 ... 104°F
Light SensorSilicon photodiode, corrected cosine angle
Display5-digit LCD
Power Source9V battery (included)
Dimensions33 x 54 x 196 mm / 1.3 x 2.1 x 7.7 in
Weight180 g / <1 lb (approx. 9.17 ounces)

8.1 Delivery Scope

The standard delivery package includes:

9. Warranty and Support

PCE Instruments provides a warranty for this product against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your purchase or visit the official PCE Instruments website. For technical support, service, or calibration inquiries, please contact PCE Instruments customer service.

PCE Instruments US: Visit Store

Related Documents - PCE-170 A

Preview PCE-170 A Mini Lux Meter Instruction Manual
Instruction manual for the PCE-170 A Mini Lux Meter by PCE Ibérica, detailing specifications, operation, safety precautions, and maintenance.
Preview PCE-4XX-EKIT Outdoor Noise Meter Kit User Manual | PCE Instruments
User manual for the PCE-4XX-EKIT Outdoor Noise Meter Kit by PCE Instruments. Provides comprehensive information on safety, introduction, delivery contents, specifications, device description, system setup, battery recharging, warranty, disposal, and contact details for this environmental noise monitoring equipment.
Preview PCE Instruments Sound Level Meters Catalog and Specifications
Comprehensive catalog detailing PCE Instruments' range of sound level meters, acoustic calibrators, and related accessories, including technical specifications, features, and applications for industrial and professional use.
Preview PCE-VT 3800/3900 Vibration Meter User Manual
User manual for PCE Instruments' PCE-VT 3800 and PCE-VT 3900 vibration meters. Covers detailed specifications, operation, measurement modes, data logging, FFT, RPM, route measurements, safety, and calibration for effective machine condition monitoring.
Preview PCE-UX 3081/3081WQ Moisture Analyzer: Operating Instructions and Technical Guide
Comprehensive operating instructions and technical specifications for the PCE-UX 3081 and PCE-UX 3081WQ moisture analyzers. Learn about setup, operation, safety, maintenance, and troubleshooting for accurate moisture and dry matter analysis using thermogravimetric methods.
Preview PCE Instruments PCE-428/430/432 Hlukoměr: Návod k obsluze a funkce
Podrobný návod k obsluze pro hlukoměry PCE Instruments PCE-428, PCE-430 a PCE-432. Zjistěte více o funkcích, technických údajích, kalibraci a obsluze těchto přesných měřicích přístrojů.