1. Important Safety Information
Please read this manual carefully before operating your Tectro TP 2520 mobile air conditioner. Keep this manual for future reference.
- Always connect the unit to a grounded power outlet.
- Do not operate the unit with a damaged cord or plug.
- Ensure the unit is placed on a flat, stable surface to prevent tipping.
- Maintain at least 30 cm (12 inches) clearance around the unit for proper airflow.
- Do not block the air inlets or outlets.
- Do not insert objects into the unit's openings.
- Unplug the unit before cleaning or performing any maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
2. Product Overview
The Tectro TP 2520 is a portable air conditioner designed to provide cooling and dehumidification for rooms up to 65 m³. It features a compact design and easy mobility.

Figure 2.1: Front view of the Tectro TP 2520 mobile air conditioner. The unit is white with a grey control panel and air vents at the top. It has wheels for easy movement.
Main Components:
- Control Panel: Located on the top, with buttons for power, mode selection, temperature adjustment, fan speed, and timer.
- Air Outlet: Adjustable louvers for directing airflow.
- Air Inlet: Located on the rear or sides, with an air filter.
- Exhaust Hose Connection: For expelling hot air.
- Drainage Port: For continuous drainage or manual emptying of condensed water.
- Casters: Wheels at the base for easy portability.
3. Setup and Installation
3.1 Unpacking
Carefully remove the air conditioner from its packaging. Retain the packaging materials for future storage or transport. Check for any damage during transit.
3.2 Placement
Place the unit on a firm, level surface in the desired room. Ensure there is at least 30 cm (12 inches) of clear space around the unit for proper air circulation. Do not place the unit near heat sources or in direct sunlight.
3.3 Exhaust Hose Installation
- Attach the exhaust hose to the designated outlet on the rear of the unit.
- Extend the hose to the nearest window or opening.
- Install the window sealing kit (if provided) to ensure hot air is expelled efficiently and to prevent outside air from entering.
- Ensure the exhaust hose is as short and straight as possible to maximize cooling efficiency. Avoid kinks or sharp bends.
3.4 Drainage Setup
The unit collects condensed water during operation. You have two options for drainage:
- Manual Drainage: The internal water tank will collect water. The unit will stop operating when the tank is full, and an indicator light will illuminate. Drain the water by removing the drain plug at the bottom rear of the unit and allowing water to flow into a suitable container.
- Continuous Drainage: For prolonged use, attach a drain hose (not always included) to the continuous drainage port and direct it to a floor drain or a larger container.
4. Operating Instructions
4.1 Control Panel Overview
The control panel features an LED display and several buttons for various functions:
- Power Button: Turns the unit on or off.
- Mode Button: Cycles through Cooling, Dehumidifying, and Fan modes.
- Temperature Up/Down Buttons: Adjusts the desired temperature in Cooling mode.
- Fan Speed Button: Selects low, medium, or high fan speed.
- Timer Button: Sets the auto-on or auto-off timer.
4.2 Operating Modes
- Cooling Mode: Reduces room temperature. Set desired temperature using the Up/Down buttons.
- Dehumidifying Mode: Removes excess moisture from the air. The fan operates at a fixed low speed.
- Fan Mode: Circulates air without cooling. Select desired fan speed.
4.3 Setting the Timer
Press the Timer button to set the desired operating duration (auto-off) or the time for the unit to automatically turn on (auto-on). Use the Up/Down buttons to adjust the hours.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always unplug the unit before cleaning.
5.1 Air Filter Cleaning
The air filter should be cleaned every two weeks, or more frequently depending on usage and air quality.
- Locate and remove the air filter from the rear or side of the unit.
- Wash the filter with warm, soapy water. Rinse thoroughly.
- Allow the filter to air dry completely before reinserting it into the unit. Do not use a dryer or direct heat.
5.2 Water Drainage
If using manual drainage, empty the water tank when the "Full Water" indicator illuminates. For continuous drainage, ensure the drain hose is not blocked and water flows freely.
5.3 Storage
Before storing the unit for an extended period:
- Drain all condensed water from the unit.
- Clean the air filter.
- Run the unit in fan-only mode for a few hours to dry the internal components.
- Unplug the power cord and coil it neatly.
- Store the unit in a cool, dry place, preferably in its original packaging.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power; power cord not plugged in; circuit breaker tripped. | Ensure power cord is securely plugged in. Check household circuit breaker. |
| Unit does not cool. | Air filter clogged; room temperature too low; exhaust hose not properly installed; windows/doors open. | Clean air filter. Adjust desired temperature. Ensure exhaust hose is sealed. Close windows and doors. |
| "Full Water" indicator is on. | Water tank is full. | Drain the water tank. |
| Unit is noisy. | Unit not on a level surface; air filter clogged. | Place unit on a level surface. Clean air filter. |
7. Technical Specifications

Figure 7.1: Energy efficiency label for Tectro TP 2520, indicating its energy class and performance metrics.
| Specification | Value |
|---|---|
| Brand | TECTRO |
| Model | TP 2520 (PVGTP2520) |
| Cooling Capacity | 2044 W (7000 BTU/h) |
| EER (Energy Efficiency Ratio) | 2.011 |
| Energy Class | A |
| Dehumidification Capacity | 38 L/24h |
| Power Consumption | 786 W/h |
| Noise Level | 55-59.8 dB(A) (Operating), 65 dB (Max) |
| Recommended Room Volume | 50-65 m³ |
| Wattage | 2000 watts |
| Voltage | 240 Volt |
| Refrigerant | R-32 |
| Weight | 23 Kilograms |
| Special Feature | Dehumidifier |
8. Warranty and Customer Support
This Tectro product is covered by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including warranty period and coverage details.
For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact Tectro customer support. Contact information can typically be found on the manufacturer's official website or on the product packaging.
Please retain your proof of purchase for warranty claims.