RYOBI P750

Download PDF
Contents

RYOBI P750 ONE+ 18V Hybrid Water Transfer Pump User Manual

Model: P750

1. Introduction

The RYOBI P750 ONE+ 18V Hybrid Water Transfer Pump is a versatile and portable solution for transferring potable water. Featuring hybrid technology, this pump can operate using either a RYOBI ONE+ 18V Lithium-Ion battery (not included) or a standard 120V AC power source via the included power adapter. Its design prioritizes portability and ease of use, making it suitable for various water transfer tasks. The pump is capable of transferring up to 325 gallons per hour (GPH).

2. Important Safety Information

Always read and understand all instructions before operating this product. Failure to follow all instructions listed below may result in electric shock, fire, and/or serious injury.

  • Personal Safety: Always wear appropriate personal protective equipment, such as safety glasses, when operating the pump. Keep children and bystanders away.
  • Electrical Safety: When using AC power, ensure the power source matches the pump's requirements. Do not operate the pump with a damaged cord or plug. Keep all electrical connections dry.
  • Water Safety: This pump is designed for potable water. Do not use it for flammable liquids, corrosive chemicals, or wastewater. Ensure the pump is properly primed before operation to prevent dry running.
  • Maintenance: Disconnect power (remove battery or unplug AC adapter) before performing any maintenance or cleaning.

3. Package Contents

Carefully unpack all items and inspect for any damage. Ensure all components are present before discarding packaging materials.

  • RYOBI P750 Hybrid Water Transfer Pump
  • Power Adaptor (for 120V AC operation)
  • Inlet Hose
  • Suction Attachment
  • Replacement Impeller
  • Replacement O-ring
  • Priming Oil
  • Operator's Manual
RYOBI P750 Hybrid Water Transfer Pump with included accessories: power adapter, inlet hose, and suction attachment.

Figure 1: RYOBI P750 pump and included accessories.

4. Specifications

FeatureSpecification
BrandRYOBI
Model NumberP750
Power Source18V Battery (ONE+ System) or 120V AC (Hybrid)
Maximum Flow Rate325 Gallons Per Hour (GPH) / 5.42 Gallons Per Minute (GPM)
Maximum Lifting Height2 Meters (approximately 6.5 feet)
Product Dimensions (L x W x H)11" x 4.5" x 6.5"
Item Weight1.35 - 1.4 Pounds
MaterialPlastic
ColorGreen
UPC033287171477
RYOBI P750 Hybrid Water Transfer Pump with dimensions labeled: 11 inches long, 4.5 inches wide, and 6.5 inches high.

Figure 2: RYOBI P750 pump dimensions.

5. Setup

Follow these steps for initial setup of your RYOBI P750 pump:

  1. Attach Hoses: Connect the inlet hose to the pump's inlet port and the outlet hose (user-supplied, typically a garden hose) to the outlet port. Ensure connections are secure to prevent leaks. For optimal performance, use a non-collapsible hose for the inlet.
  2. Positioning: Place the pump on a stable, level surface. The included free-standing base allows the pump to stand independently.
  3. Power Source:
    • Battery Operation: Insert a fully charged RYOBI ONE+ 18V battery into the battery compartment.
    • AC Operation: Connect the power adapter to the pump's AC port and then plug it into a standard 120V AC outlet.
  4. Priming the Pump: Before each use, it is recommended to place two drops of the provided priming oil into the inlet port. This lubricates the internal rubber impeller, preventing it from drying out and ensuring efficient operation.
RYOBI P750 Hybrid Water Transfer Pump actively draining water from a sink, with hoses connected to the inlet and outlet ports.

Figure 3: Pump in operation, demonstrating hose connections.

6. Operating Instructions

Once the pump is set up and primed, follow these steps to operate it:

  1. Submerge Inlet: Ensure the suction attachment and the end of the inlet hose are fully submerged in the liquid to be transferred.
  2. Turn On: Locate the ON/OFF switch on the pump and switch it to the 'ON' position. The 'Power On' indicator light should illuminate.
  3. Monitor Operation: Observe the flow of water from the outlet hose. The pump will begin transferring water.
  4. Indicator Lights: The pump features several indicator lights to provide operational status:
    • Power On: Solid light indicates the pump is receiving power.
    • Pump Run Dry: Blinking light indicates the pump is running without water. The pump will shut off automatically to prevent damage.
    • Motor Over Temp: Blinking light indicates the motor is overheating. The pump will shut off automatically. Allow it to cool before restarting.
    • Overload: Blinking light (two dots, pause, two dots) indicates an overload condition. The pump will shut off automatically. Check for obstructions or excessive back pressure.
  5. Turn Off: Once the desired amount of liquid has been transferred or the source is depleted, switch the pump to the 'OFF' position.

Note: This pump is ideal for smaller liquid transfer tasks. For very large volumes, such as draining a large pond, a higher capacity pump may be more suitable due to the P750's inlet/outlet size and impeller design.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your RYOBI P750 pump.

  • After Each Use: After transferring water, especially if it contains any sediment, flush the pump with clean water to remove debris.
  • Impeller Lubrication: As mentioned in the setup, apply two drops of priming oil to the inlet before and after each use to keep the rubber impeller lubricated and prevent it from drying out.
  • Storage: Store the pump in a dry, protected area when not in use. If storing for an extended period, ensure all water is drained from the pump and hoses to prevent freezing damage.
  • Impeller and O-ring Replacement: Periodically inspect the impeller and O-ring for wear or damage. Replace them with the provided spares or genuine RYOBI parts as needed.
  • Cleaning: Wipe down the exterior of the pump with a damp cloth. Do not use harsh chemicals or abrasive cleaners.

8. Troubleshooting

Refer to the following table for common issues and their solutions:

ProblemPossible CauseSolution
Pump does not turn onNo power, dead battery, AC adapter unplugged.Ensure battery is charged and properly inserted, or AC adapter is securely plugged in.
Pump runs but no water flowsPump not primed, inlet hose not submerged, air leak in inlet hose, clogged inlet/outlet.Prime the pump with oil, ensure inlet is fully submerged, check hose connections for tightness, clear any obstructions.
Pump runs dry (indicator light blinking)Liquid source depleted, inlet hose out of water.Turn off pump, replenish liquid source or reposition inlet hose, then restart.
Motor overheats (indicator light blinking)Extended use, insufficient cooling, high ambient temperature.Turn off pump and allow it to cool down for at least 15-30 minutes before restarting.
Overload (indicator light blinking two dots, pause, two dots)Obstruction in pump/hoses, excessive back pressure, attempting to pump too viscous a liquid.Turn off pump, inspect and clear any obstructions in hoses or pump, ensure outlet hose is not kinked or blocked.
Pump is excessively noisyNormal operation (some noise is expected), pump running dry, air in the system.Ensure pump is fully primed and inlet hose is submerged. Some noise during priming is normal.
Slow flow ratePartially clogged inlet/outlet, long or narrow outlet hose, pump not fully primed.Check for clogs, use a wider diameter outlet hose if possible, ensure pump is properly primed. Avoid lightweight expansion hoses on the outlet.

9. Warranty and Support

The RYOBI P750 ONE+ 18V Hybrid Water Transfer Pump is backed by a RYOBI 3-Year Manufacturer's Warranty. This warranty covers defects in material and workmanship from the date of purchase.

For warranty claims, technical support, or to purchase replacement parts, please contact RYOBI customer service directly. Keep your proof of purchase for warranty validation.

© 2026 RYOBI. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.