Introduction
This manual provides essential instructions for the safe installation, operation, and maintenance of your Sta-Rite JHE-63HL Centrifugal Pump. Please read this manual thoroughly before attempting to install or operate the pump. Retain this manual for future reference.
Safety Information
Always observe all safety precautions to prevent personal injury and equipment damage. Ensure all electrical work is performed by a qualified electrician and complies with local codes. Disconnect power before servicing the pump.
- Electrical Hazard: Ensure proper grounding and wiring.
- Moving Parts: Keep hands and clothing clear of moving parts.
- Hot Surfaces: Pump motor and casing may become hot during operation.
- Pressure Hazard: Relieve system pressure before servicing.
Setup and Installation
1. Location
Install the pump in a dry, well-ventilated area, protected from freezing temperatures and direct sunlight. Ensure adequate space for maintenance and service. The pump should be installed on a firm, level foundation to minimize vibration.
2. Plumbing Connections
Connect the suction line to the 1-1/4" NPT inlet and the discharge line to the 1" NPT outlet. Use appropriate thread sealant on all connections. Avoid overtightening to prevent damage. Ensure all piping is adequately supported to prevent strain on the pump casing.
- Use unions for easy removal of the pump.
- Install a check valve in the discharge line if the pump is above the water source.
- Ensure suction piping is as short and direct as possible with minimal elbows.
3. Electrical Wiring
The JHE-63HL pump operates on 115/230 VAC. Ensure the motor is wired for the correct voltage supply. All wiring must comply with national and local electrical codes. A dedicated circuit with appropriate overcurrent protection is recommended.
- Verify the voltage setting on the motor before connecting power.
- Ensure the pump is properly grounded to prevent electrical shock.
- Use waterproof connectors and conduit for outdoor installations.
4. Priming the Pump
Before initial startup, the pump casing must be filled with water. Remove the priming plug (if present) or open a valve on the discharge side and fill the pump casing and suction line with water until all air is expelled. Replace the plug or close the valve before starting the pump.
Operation
1. Initial Startup
After priming, turn on the power supply to the pump. The pump should start and begin moving water. Listen for unusual noises or vibrations. If the pump does not prime within a few minutes, turn it off, re-prime, and try again.
2. Continuous Operation
Monitor the pump's performance during operation. Ensure there are no leaks and that the flow rate is consistent with system requirements. Avoid running the pump dry, as this can cause severe damage to the mechanical seal and impeller.
3. Shutting Down
To shut down the pump, simply turn off the power supply. For extended periods of non-use, especially in freezing conditions, drain the pump completely to prevent damage.
Maintenance
Regular maintenance ensures optimal performance and extends the life of your pump. Always disconnect power before performing any maintenance.
1. Routine Checks
- Monthly: Inspect for leaks around seals and connections. Check for unusual noises or vibrations.
- Annually: Inspect the motor for proper ventilation. Check electrical connections for tightness and corrosion.
2. Impeller Inspection
The JHE-63HL features a Noryl impeller, known for its abrasion resistance. Periodically inspect the impeller for wear or damage, especially if the pump's performance decreases. Consult a qualified technician for impeller replacement.
3. Winterization
In areas subject to freezing temperatures, the pump must be drained completely to prevent damage from ice expansion. Remove drain plugs and allow all water to escape. Store the pump in a warm, dry place if possible, or ensure it is thoroughly dry and protected from elements.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; tripped breaker; faulty motor. | Check power supply and breaker. Consult electrician if motor is faulty. |
| Pump runs but no water flow | Pump not primed; air leak in suction line; clogged impeller. | Re-prime the pump. Check suction line for leaks. Inspect and clear impeller. |
| Low flow or pressure | Partial clog; air in system; worn impeller; incorrect voltage. | Clear clogs. Bleed air from system. Inspect impeller. Verify correct voltage. |
| Excessive noise or vibration | Cavitation; loose mounting; worn bearings. | Ensure adequate water supply. Tighten mounting bolts. Consult technician for bearings. |
Specifications
- Model: JHE-63HL
- Horsepower: 1 HP
- Voltage: 115/230 VAC
- Inlet Connection: 1-1/4" NPT
- Outlet Connection: 1" NPT
- Maximum Flow Rate: 60 GPM
- Maximum Pressure: 48 PSI
- Maximum Lifting Height: 25 Feet
- Material (Casing): Cast Iron
- Material (Impeller): Noryl
- Item Weight: 48 Pounds
Performance Curve

This graph illustrates the performance characteristics of the Sta-Rite JHE series centrifugal pumps. The horizontal axis represents the pump's capacity in both gallons per minute (GPM) and liters per minute (LPM). The vertical axis shows the total head in both feet and meters. Multiple curves are displayed, each corresponding to a different motor horsepower (1/3 HP, 1/2 HP, 3/4 HP, 1 HP, 1-1/2 HP, 2 HP, 2-1/2 HP). A shaded area indicates the recommended operating range for optimal efficiency and longevity. The 1 HP curve, relevant to the JHE-63HL model, shows its performance within this range.
Warranty Information
Sta-Rite products are backed by a manufacturer's warranty covering defects in materials and workmanship. The specific terms and duration of the warranty may vary. Please refer to the warranty card included with your product or visit the official Sta-Rite website for detailed information. Keep your proof of purchase for warranty claims.
Customer Support
For technical assistance, replacement parts, or further information, please contact Sta-Rite customer support or your authorized dealer. When contacting support, please have your pump model number (JHE-63HL) and serial number available.
Contact information (example):
- Website: www.pentair.com/sta-rite
- Phone: Refer to your local dealer or product packaging.