1. Introduction
The CONTEC ABPM50 is a portable, automatic blood pressure monitor designed for continuous 24-hour ambulatory blood pressure monitoring. It utilizes oscillography theory to provide accurate blood pressure measurements for adults, pediatric, and neonate patients. This device is suitable for use in various settings, including hospitals, homes, and outdoors. It features a high-definition color TFT display for clear visibility of data and offers comprehensive data management capabilities through PC communication.
The ABPM50 supports both instant and ambulatory blood pressure monitoring modes, allowing users to tailor the monitoring experience to their specific needs. It can store up to 350 groups of NIBP data and provides various data review interfaces such as data lists, trend graphs, and large font displays for easy interpretation. The device also includes clear alerts for low battery and error messages, ensuring reliable operation.
2. Safety Information
- Read the entire manual before using the device.
- Consult a healthcare professional for interpretation of blood pressure readings. Self-diagnosis and treatment based on measurements can be dangerous.
- Do not use the device on infants or individuals who cannot communicate their discomfort.
- Ensure the cuff size is appropriate for the user's arm circumference to obtain accurate readings.
- Avoid placing the cuff over wounds or inflamed areas.
- Do not use the device in an environment with strong electromagnetic interference.
- Keep the device away from water and extreme temperatures.
- Use only specified accessories and replacement parts.
- Dispose of batteries and the device according to local regulations.
3. Package Contents
Verify that all items are present in the package:
- CONTEC ABPM50 Blood Pressure Monitor unit
- NIBP Adult cuff (25-35 cm arm circumference)
- Carrying case
- USB cable
- Extend tube
- User Manual

Image: Contents of the CONTEC ABPM50 package, showing the monitor, cuff, USB cable, and carrying case.
4. Setup
4.1 Battery Installation
The device requires 2 AAA batteries. To install:
- Open the battery compartment cover on the back of the device.
- Insert 2 AAA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.

Image: Battery compartment of the ABPM50, illustrating how to insert AAA batteries.
4.2 Cuff Connection
Connect the NIBP cuff to the monitor unit:
- Locate the air tube connector on the side of the ABPM50 unit.
- Firmly insert the cuff's air tube connector into the port until it clicks into place.
Video: Demonstrates connecting the blood pressure cuff to the CONTEC ABPM50 monitor and proper cuff placement on the arm. This video shows the setup process for continuous monitoring.

Image: Close-up of the cuff tube being connected to the monitor.
4.3 Cuff Placement
Proper cuff placement is crucial for accurate readings:
- Slide the cuff onto your upper arm, ensuring the air tube is positioned over the brachial artery (inner side of the arm).
- The bottom edge of the cuff should be approximately 2-3 cm above the elbow joint.
- Wrap the cuff snugly around your arm, but not too tightly. The index line on the cuff should fall within the "RANGE" indicator.
- Rest your arm on a flat surface with your palm facing upwards. Ensure the cuff is at heart level.

Image: Proper placement of the adult blood pressure cuff on the upper arm.
5. Operating Instructions
5.1 Device Overview and Controls
The ABPM50 features a color TFT display and several control buttons:

Image: Labeled diagram of the ABPM50 monitor's buttons and screen functions.
- Up/Down Arrows: Navigate through menus and data.
- Menu Button (middle button on screen): Access the main menu.
- OK/Enter Button (right key on screen): Confirm selections.
- Start/Stop Button (green button): Initiate or stop a measurement.
- On/Off Button (bottom left button): Power the device on or off.
- Return Button (bottom right button): Go back to the previous screen or main interface.
5.2 Taking a Measurement (Instant Mode)
- Ensure the cuff is correctly placed on your arm.
- Press the On/Off button to power on the device.
- From the main screen, press the Start/Stop button (green button) to begin a measurement. The cuff will inflate, and the measurement will proceed automatically.
- Remain still and quiet during the measurement.
- Once complete, your systolic, diastolic, and pulse rate will be displayed on the screen.
Video: Demonstrates the process of taking an instant blood pressure measurement using the CONTEC ABPM50 monitor, including cuff application and reading results.
5.3 Ambulatory Blood Pressure Monitoring (ABPM)
For 24-hour continuous monitoring:
- Access the device's menu to select the ABPM mode.
- Set the desired measurement intervals (e.g., every 15, 30, or 60 minutes).
- Ensure the cuff is securely and comfortably placed for extended wear.
- Wear the device using the provided carrying case and strap for convenience.
- The device will automatically take measurements at the set intervals.

Image: The ABPM50 monitor worn in its carrying case, ready for ambulatory monitoring.
6. Data Management
6.1 On-Device Data Review
The ABPM50 can store up to 350 groups of NIBP data. To review data on the device:
- Navigate through the menu to "Data List" to view individual measurements.
- Select "Trend Graph" to see a visual representation of your blood pressure trends over time.
- Use the "Big Font" option for enhanced readability of current readings.

Image: The ABPM50 display showing current blood pressure readings and menu options.
6.2 PC Software Communication
The device can connect to a PC for advanced data analysis and reporting:
- Install the provided PC software on your computer (compatible with Windows 10).
- Connect the ABPM50 to your PC using the supplied USB cable.
- Launch the software to download NIBP measurement results from the device.
- The software allows for:
- Data review and analysis.
- Display of scoop-shape trend graphs, filling-type trend graphs, histograms, pie charts, and correlation line graphs.
- Editing of NIBP data and adding annotations.
- Editing basic patient information, doctor's advice, NIBP status, and current medication.
- Printing comprehensive reports.
Video: Overview of the CONTEC ABPM50 Ambulatory Blood Pressure Monitor, highlighting its 24-hour monitoring capabilities and PC software for data analysis and reporting.
7. Maintenance
- Cleaning: Wipe the device and cuff with a soft, dry cloth. If necessary, use a cloth lightly dampened with water or a mild disinfectant. Do not immerse the device or cuff in water.
- Storage: Store the device in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
- Battery Replacement: Replace batteries when the low battery alert appears on the screen. Remove batteries if the device will not be used for an extended period.
- Cuff Care: Do not wash the inner air bag of the cuff. Inspect the cuff regularly for wear and tear.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on or turns off unexpectedly. | Low or depleted batteries; incorrect battery installation; poor battery connection. | Replace batteries with new ones, ensuring correct polarity. Check battery contacts for proper connection. |
| "No Data Found" message after downloading data to PC. | Software communication glitch; data not properly transferred. | Ensure the device is correctly connected via USB. Restart the PC software and try downloading again. Verify data is present on the device screen before attempting download. |
| Inaccurate or inconsistent readings. | Improper cuff placement; incorrect cuff size; movement during measurement; speaking during measurement. | Re-position the cuff correctly. Ensure the cuff size matches your arm circumference. Remain still and silent during measurements. Consult a healthcare professional if issues persist. |
| Cannot access "PROMPT SOUND" menu. | Password protected menu. | The password for the "PROMPT SOUND" menu is 8015. |
| Cuff does not inflate or inflates too slowly. | Loose cuff connection; air leakage in cuff or tube; pump malfunction. | Check that the cuff tube is securely connected to the monitor. Inspect the cuff and tube for any visible damage or leaks. |
9. Specifications
- Model Name: ABPM50
- Item Model Number: BD3217
- Brand: CONTEC
- Power Source: Battery Powered (2 AAA batteries required)
- Display Type: Digital, High-definition color TFT display
- Product Dimensions: 9.65"L x 2.56"W x 5.63"Th (Device only)
- Cuff Size: Adult (25-35 cm arm circumference, Bladder size: 13.1 x 23.5 cm)
- Data Storage: Up to 350 groups of NIBP data
- Measurement Method: Oscillography
- Applicable Age Range: Adult, Pediatric, Neonate (with appropriate cuffs, sold separately if not included)
- Connectivity: USB for PC communication
- Units: mmHg / kPa (switchable)
- UPC: 756040906160
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided with your product packaging or visit the official CONTEC website. Keep your purchase receipt as proof of purchase for warranty claims.
You can consult us at any time if you need assistance.