1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Faber TENDER 3D Max T2S2 60cm Chimney. Please read these instructions carefully before using the appliance and retain them for future reference.

Image: Faber TENDER 3D Max T2S2 60cm Chimney, showcasing its stainless steel pyramid design.
2. Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons.
- Ensure the power supply matches the voltage specified on the appliance.
- Do not operate the chimney with a damaged cord or plug.
- Installation should be performed by a qualified technician.
- Clean filters regularly to prevent grease buildup, which can be a fire hazard.
- Do not flambé under the range hood.
- Keep children away from the appliance during operation.
- Disconnect power before cleaning or servicing.
3. Product Features
The Faber TENDER 3D Max T2S2 chimney is designed for efficient kitchen ventilation with several key features:
- Size: 60 cm, suitable for 2-4 burner stoves.
- Suction Capacity: 1295 m³/hr, ideal for kitchens over 200 sqft and heavy frying/grilling.
- 3-Way Suction: Enhanced smoke and odor extraction from multiple directions.
- Filter Type: Two triple-layer Baffle Filters, designed for Indian cooking conditions.
- Control Type: User-friendly Push Button Control.
- Noise Level: Maximum 58 Decibels.
- Mounting Type: Wall Mounted Pyramid design.
- Light Source: Integrated LED lighting for illuminated cooking.
- Material: Durable Stainless Steel construction.

Image: Illustration of 3-Way Suction technology for comprehensive smoke capture.

Image: Close-up of the Baffle Filter, designed to separate grease particles.

Image: Push Button Control panel for easy operation of fan speeds and lighting.
4. Setup and Installation
The Faber TENDER 3D Max T2S2 is a wall-mounted chimney. Proper installation is crucial for optimal performance and safety. It is highly recommended to have the chimney installed by a certified technician.
4.1 Pre-Installation Checks
- Verify that the wall structure can support the weight of the chimney (approximately 10 kg).
- Ensure adequate clearance between the cooking surface and the chimney as per local regulations and manufacturer guidelines.
- Confirm availability of a suitable electrical outlet.
- Decide between ducted or ductless (recirculating) installation. For ductless, charcoal filters are required (sold separately).
4.2 Installation Steps (Overview)
- Mark the drilling points on the wall according to the provided template.
- Drill holes and insert wall plugs.
- Mount the chimney bracket securely.
- Hang the chimney body onto the bracket.
- Connect the exhaust ducting (if ducted) or install charcoal filters (if ductless).
- Connect the power supply.
- Test the chimney's functions.
Note: Detailed installation instructions with diagrams are typically provided in the physical user manual included with the product.
5. Operating Instructions
Your Faber chimney features intuitive push-button controls for ease of use.
5.1 Control Panel Functions
- Power Button: Turns the chimney ON/OFF.
- Fan Speed Buttons (1, 2, 3): Adjusts the suction power. Level 1 is for light cooking, Level 3 for heavy frying or grilling.
- Light Button: Controls the integrated LED lighting. Press once to turn ON, press again to turn OFF.
5.2 General Operation Tips
- Turn on the chimney a few minutes before you start cooking to establish airflow.
- Select the appropriate fan speed based on the intensity of cooking fumes.
- Allow the chimney to run for a few minutes after cooking to clear any residual smoke and odors.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your chimney.
6.1 Baffle Filter Cleaning
Baffle filters should be cleaned regularly to maintain suction efficiency and prevent fire hazards. For typical Indian cooking, cleaning every 2 weeks is recommended, or at least every 6 months.
- Disconnect Power: Always switch off and unplug the chimney before cleaning.
- Remove Filters: Carefully unlatch and remove the baffle filters.
- Clean Filters: Soak filters in hot water with a degreasing agent or dish soap for 30-60 minutes. Scrub gently with a non-abrasive brush to remove grease. Alternatively, some baffle filters are dishwasher safe (check your specific model's manual).
- Rinse and Dry: Rinse thoroughly with clean water and allow them to dry completely before re-installing.
- Re-install Filters: Place the dry filters back into their slots, ensuring they are securely latched.
6.2 Exterior Cleaning
- Wipe the exterior surfaces with a soft cloth dampened with mild soap and water.
- Do not use abrasive cleaners, steel wool, or harsh chemicals, as these can damage the stainless steel finish.
- Dry thoroughly with a clean, soft cloth.
6.3 Charcoal Filter Replacement (for Ductless Mode)
If your chimney is installed in ductless mode, charcoal filters are used to absorb odors. These filters cannot be cleaned and must be replaced periodically, typically once a year, depending on usage.
- Refer to your specific model's instructions for charcoal filter replacement.
- Ensure you purchase the correct replacement filters for the HOOD TENDER 3D model.
7. Troubleshooting
Before contacting customer service, please refer to the following troubleshooting guide for common issues.
| Problem | Possible Cause | Solution |
|---|---|---|
| Chimney does not turn ON. | No power supply; loose plug; tripped circuit breaker. | Check power cord connection; check circuit breaker; test electrical outlet. |
| Low suction power. | Clogged baffle filters; incorrect fan speed; obstruction in ducting (if ducted). | Clean baffle filters; select higher fan speed; check ducting for blockages. Replace charcoal filters if in ductless mode. |
| Excessive noise. | Loose parts; motor issue; improper installation; ducting issues. | Ensure all parts are secure; check for foreign objects; verify proper ducting installation. Note that some noise is normal, especially at higher speeds. |
| Lights not working. | Faulty LED bulb; loose connection. | Check light button; if bulb is replaceable, replace it (consult service manual); contact service if issue persists. |
If the problem persists after attempting these solutions, please contact Faber customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Brand | Faber |
| Model Number | HOOD TENDER 3D |
| Product Dimensions (D x W x H) | 51D x 60W x 67H Centimeters |
| Colour | Stainless steel |
| Air Flow Capacity | 1295 Cubic Meters Per Hour |
| Noise Level | 58 Decibels |
| Mounting Type | Wall Mount |
| Controls Type | Push Button |
| Voltage | 220 Volts |
| Light Source | LED |
| Filter Type | Baffle |
| Ventilation Type | Convertible |
| Item Form | Pyramid |
| Item Weight | 10 Kilograms |
| Included Components | 1 chimney, 1 User Manual |
9. Warranty and Support
9.1 Warranty Information
Your Faber TENDER 3D Max T2S2 chimney comes with a comprehensive warranty:
- Product Warranty: 1 year on the entire product.
- Motor Warranty: 12 years on the motor.
Please retain your purchase receipt for warranty claims. The warranty covers manufacturing defects under normal use conditions.
9.2 Customer Support
For any service, installation, or technical assistance, please contact Faber customer support:
- Manufacturer: Franke Faber India Pvt Ltd
- Contact Number: 1800-209-3484
- Address: 1086/1/2, SANASWADI, TAL - SHIRUR, PUNE - 412208, MAHARASHTRA, INDIA
When contacting support, please have your model number (HOOD TENDER 3D) and purchase details ready.