1. Introduction
This manual provides essential information for the safe and efficient operation of your Eventek KPS-3010D Digital Adjustable DC Power Supply. This device is designed to provide a stable and adjustable DC voltage and current output, suitable for various electronic applications, laboratory work, and repair tasks. Please read this manual thoroughly before use and retain it for future reference.
2. Safety Instructions
To prevent electric shock, fire, or damage to the product, please observe the following safety precautions:
- Always connect the power supply to a grounded AC outlet.
- Do not operate the device in wet or damp conditions.
- Ensure proper ventilation. Do not block the cooling fan or vents.
- Do not open the casing. Refer all servicing to qualified personnel.
- Verify the input voltage matches your local power supply before connecting.
- Avoid short-circuiting the output terminals.
- The unit features multiple protections: overcurrent limit, thermal protection, overvoltage protection, and short-circuit protection. However, always operate within specified limits.
- Disconnect power before making any connections or disconnections to the output terminals.
3. Package Contents
Verify that all items are present in the package:
- Eventek KPS-3010D DC Power Supply Unit
- AC Power Cord (EU/UK type, depending on region)
- Output Test Leads (Alligator clip to banana plug cables)
- User Manual
4. Product Overview
4.1 Front Panel

This image provides a clear front view of the Eventek KPS-3010D power supply, showing the display, control knobs, power switch, and output terminals.
- LED Display: Shows real-time voltage (V) and current (A) output. Indicators for Constant Voltage (CV) and Constant Current (CC) modes are also present.
- Voltage Adjustment Knobs (COARSE/FINE): Used to set the output voltage. 'COARSE' for large adjustments, 'FINE' for precise adjustments.
- Current Adjustment Knobs (COARSE/FINE): Used to set the output current limit. 'COARSE' for large adjustments, 'FINE' for precise adjustments.
- Power Switch: Turns the unit ON or OFF.
- Output Terminals (+/-): Connect your load here using the provided test leads.

This image illustrates the high-precision LED display, showing voltage (V) and current (A) readings. It highlights the 3-digit display for voltage and current, with 10A current output and 30V voltage output capabilities.

This image details the precision adjustment controls. It shows the "COARSE" knob for larger adjustments and the "FINE" knob for precise, incremental changes in both voltage and current.
4.2 Rear Panel

This image provides a rear view of the power supply, highlighting the cooling fan and the AC power input socket.
- AC Power Input: Connect the provided AC power cord here.
- Cooling Fan: Automatically activates to dissipate heat and maintain optimal operating temperature.
5. Setup
- Unpacking: Carefully remove the power supply and all accessories from the packaging. Inspect for any signs of damage.
- Placement: Place the power supply on a stable, level surface with adequate ventilation. Ensure that the front and rear vents are not obstructed.
- Power Connection: Connect the supplied AC power cord to the AC power input socket on the rear panel of the power supply, then plug the other end into a grounded AC outlet.
- Initial Check: Before connecting any load, ensure all voltage and current adjustment knobs are turned fully counter-clockwise (to their minimum settings).
6. Operating Instructions
6.1 Powering On/Off
- To turn ON, press the power switch on the front panel. The LED display will illuminate.
- To turn OFF, press the power switch again.
6.2 Setting Voltage and Current
- Pre-setting Voltage (No Load): With no load connected to the output terminals, turn the voltage adjustment knobs (COARSE and FINE) clockwise to set the desired output voltage. Observe the voltage reading on the LED display.
- Pre-setting Current Limit (Short Circuit Method - Use with Caution):
- Turn the voltage knobs to minimum.
- Briefly short-circuit the output terminals using a test lead (ensure this is done quickly to avoid overheating). The CC indicator will light up.
- Adjust the current adjustment knobs (COARSE and FINE) to set the desired current limit.
- Remove the short circuit. The CC indicator will turn off, and the CV indicator will light up.
- Connecting Load: Connect your device or circuit to the output terminals using the provided test leads. Ensure correct polarity (+ to + and - to -).
- Operation with Load: Once the load is connected, the power supply will operate in either Constant Voltage (CV) or Constant Current (CC) mode, indicated by the respective LED.
6.3 Constant Voltage (CV) and Constant Current (CC) Modes
- Constant Voltage (CV) Mode: When the load current is below the set current limit, the power supply maintains the set output voltage. The CV indicator will be lit.
- Constant Current (CC) Mode: When the load current reaches the set current limit, the power supply automatically switches to CC mode, reducing the output voltage to maintain the set current. The CC indicator will be lit. This protects the connected device from overcurrent.
7. Maintenance
Proper maintenance ensures the longevity and reliable operation of your power supply.
- Cleaning: Disconnect the power supply from the AC outlet before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
- Ventilation: Regularly check that the cooling fan and vents are free from dust and obstructions. The intelligent temperature control system activates the fan when the internal temperature exceeds 50°C to ensure efficient cooling and extend product life.
- Storage: When not in use for extended periods, store the power supply in a cool, dry place, away from direct sunlight and extreme temperatures.

This image demonstrates the intelligent cooling design of the power supply. It shows the internal fan mechanism, which activates when the internal temperature exceeds 50°C, enhancing safety and performance.
8. Troubleshooting
If you encounter issues with your power supply, refer to the following table:
| Problem | Possible Cause | Solution |
|---|---|---|
| No power/display | Power cord not connected; Power switch off; No AC power. | Check power cord connection; Turn on power switch; Verify AC outlet is live. |
| No output voltage/current | Voltage/current knobs set to minimum; Output terminals not connected correctly; Overload/short circuit. | Adjust voltage/current knobs; Check connections; Disconnect load and check for short circuit. |
| CC indicator always on | Current limit set too low for the load; Load drawing excessive current; Short circuit. | Increase current limit; Check load for faults; Disconnect load and check for short circuit. |
| Fan running constantly/loudly | High internal temperature; Obstructed vents. | This is normal during high load or in warm environments; Ensure vents are clear. |
9. Specifications
| Feature | Specification |
|---|---|
| Model Number | KPS-3010D |
| Input Voltage | AC 220V ±10% (or as per regional variant) |
| Output Voltage Range | 0-30V DC |
| Output Current Range | 0-10A |
| Display Precision (Voltage) | 0.1V |
| Display Precision (Current) | 0.01A |
| Load Regulation (CV) | ≤0.1% + 1mV |
| Load Regulation (CC) | ≤0.1% + 3mA |
| Line Regulation (CV) | ≤0.01% + 3mV |
| Line Regulation (CC) | ≤0.2% + 6mA |
| Ripple and Noise (CV) | ≤20mVrms |
| Ripple and Noise (CC) | ≤20mArms |
| Cooling Method | Intelligent Air Cooling |
| Operating Temperature | 0°C to 40°C |
| Weight | 1.45 kg |
| Dimensions (approx.) | Compact design (specific dimensions not provided, refer to product images for scale) |
10. Warranty and Support
Eventek products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims.