Parker 6606 25 00

Parker 6606 25 00 Tube Fitting User Manual

Model: 6606 25 00

Brand: Parker

1. Introduction

This manual provides comprehensive instructions for the proper installation, operation, and maintenance of the Parker 6606 25 00 Tube Fitting. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

The Parker 6606 25 00 is a straight, equal tube fitting designed for fluid system connections, specifically with a 25mm dimension.

Front view of the Parker 6606 25 00 Tube Fitting, a black cylindrical component with two wider ends.

Figure 1: Front view of the Parker 6606 25 00 Tube Fitting.

2. Product Overview

The Parker 6606 25 00 Tube Fitting is a critical component for creating secure and leak-free connections in various industrial fluid systems. Its robust design ensures reliable performance under specified operating conditions.

Key Features:

Angled view of the Parker 6606 25 00 Tube Fitting, showing its textured ends and smooth central body.

Figure 2: Angled view of the Parker 6606 25 00 Tube Fitting.

3. Setup and Installation

Proper installation is crucial for the performance and longevity of the Parker 6606 25 00 Tube Fitting. Follow these steps carefully:

  1. Preparation: Ensure all components are clean and free from debris. Verify that the tube ends are properly cut and deburred.
  2. Component Assembly: Slide the nut, then the back ferrule, and finally the front ferrule onto the tube. Ensure the ferrules are oriented correctly.
  3. Tube Insertion: Insert the tube into the fitting body until it bottoms out.
  4. Nut Tightening: While holding the fitting body steady, tighten the nut finger-tight. Then, using a wrench, tighten the nut 1-1/4 turns past finger-tight for sizes 1/4" to 1" (or equivalent for 25mm). For larger sizes, consult specific Parker torque specifications.
  5. Inspection: Visually inspect the connection for proper alignment and tightness.

Warning:

Another angled view of the Parker 6606 25 00 Tube Fitting, highlighting the connection points and central 'transair' branding.

Figure 3: Close-up view of the Parker 6606 25 00 Tube Fitting, illustrating connection points.

4. Operating Guidelines

Once installed, the Parker 6606 25 00 Tube Fitting operates passively as a connection point within a fluid system. No active operation or user interaction is required from the fitting itself during system operation.

Ensure the system pressure and temperature remain within the specified limits for the fitting and the overall system. Regular monitoring of the system for leaks or anomalies is recommended to maintain optimal performance and safety.

5. Maintenance

The Parker 6606 25 00 Tube Fitting is designed for long-term reliability with minimal maintenance. However, periodic checks are recommended to ensure continued integrity of the fluid system:

Caution:

6. Troubleshooting

This section addresses common issues that may arise with tube fittings and provides potential solutions.

ProblemPossible CauseSolution
Leak at connection point
  • Improper tightening (under or over)
  • Damaged ferrule or fitting body
  • Incorrect tube preparation (e.g., not deburred, ovality)
  • Incompatible tube material or size
  • Depressurize system, disassemble, inspect components, and reassemble correctly following installation steps.
  • Replace any damaged ferrules or fitting components with new, genuine Parker parts.
  • Ensure tube ends are cut squarely and deburred properly.
  • Verify tube material and size compatibility with the fitting.
Difficulty inserting tube
  • Tube end not deburred or burrs present
  • Incorrect tube size (too large)
  • Deformed tube end
  • Deburr tube end thoroughly using a proper deburring tool.
  • Verify tube diameter matches fitting size (25mm).
  • Recut or replace tube if end is deformed.

7. Specifications

Detailed specifications for the Parker 6606 25 00 Tube Fitting:

8. Warranty Information

Parker products are manufactured to high standards of quality and reliability. For specific warranty details regarding the Parker 6606 25 00 Tube Fitting, please refer to the official Parker warranty policy available on their corporate website or contact an authorized Parker distributor. Typically, warranties cover defects in material and workmanship under normal use and service conditions.

9. Customer Support

For technical assistance, product inquiries, or to report any issues related to your Parker 6606 25 00 Tube Fitting, please contact Parker customer support or your authorized distributor. When contacting support, ensure you have your product model number (6606 25 00) and any relevant purchase information ready to facilitate a quicker resolution.

You can find more information and contact details on the official Parker website: www.parker.com

Related Documents - 6606 25 00

Preview Parker Pargrip PFA Tube Fittings: Specifications and Assembly Instructions
Comprehensive guide to Parker Pargrip PFA tube fittings, detailing assembly procedures, product specifications, dimensions, and part numbers for a wide range of fittings including adaptors, connectors, tees, and reducers.
Preview Parker EOMAT PRO: Cost-Effective Tube Line Assembly Machine
A comprehensive guide to the Parker EOMAT PRO, an automated assembly machine designed for cost-effective and process-safe production of tube lines with EO-2 and Progressive Ring fittings. This document details its features, benefits, operational modes (automatic and manual), specifications, assembly instructions, and ordering information.
Preview Parker CPI™/A-LOK® Tube Fittings and Instrumentation Valves Catalog 4200-PC
Explore Parker's comprehensive Catalog 4200-PC, featuring the robust CPI™/A-LOK® Tube Fittings and Instrumentation Valves. Designed for demanding process, power, and instrumentation applications, these components ensure reliable, leak-free connections under high pressure, vacuum, and vibration. This catalog provides detailed specifications, assembly instructions, and material options for a wide array of fittings and valves.
Preview Parker Parflange® 170 ECO & WCM: Tube Flaring Machines for F37 Connections
Detailed overview of Parker Parflange® 170 ECO and WCM workshop machines for 37° orbital tube flaring, designed for F37 flange connections. Features, specifications, tool selection, and benefits for industrial applications.
Preview Parker NitroFlow Lab User Manual: Nitrogen Generator Guide
Comprehensive user manual for the Parker NitroFlow Lab nitrogen generator. Learn about installation, operation, maintenance, safety, and troubleshooting for this advanced gas generation system.
Preview Parker AC20 Series Variable Speed Drive Software Reference Manual
A comprehensive software reference manual for the Parker AC20 Series Variable Speed Drive, detailing its configuration, operation, programming, and troubleshooting for industrial applications.