Lawrence LH8016

Lawrence LH8016 Extra Heavy Duty Commercial Door Closer Instruction Manual

Model: LH8016

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Lawrence LH8016 Extra Heavy Duty Commercial Grade 1 Door Closer. Designed for high-traffic environments, this door closer offers reliable and controlled door closure, enhancing safety and energy efficiency.

Lawrence LH8016 Extra Heavy Duty Commercial Door Closer

Image 1.1: The Lawrence LH8016 Extra Heavy Duty Commercial Door Closer.

Key Features:

  • Heavy-Duty Door Control: Engineered for robust performance in commercial settings, managing door movement effectively.
  • Adjustable 6-Speed Delayed-Action: Allows precise control over closing speed, latching speed, and delayed action for various applications.
  • Flexible Installation: Compatible with multiple mounting configurations (Regular, Parallel, Top Jamb) for diverse door types and frames.
  • UL & ADA Compliant: Certified for safety and accessibility, meeting industry standards.
  • Durable Construction: Built with quality materials for long-lasting performance.
Features of Lawrence LH8016 Door Closer including daily openings, max door weight, and dimensions

Image 1.2: Overview of key features and specifications for the LH8016 door closer, including capacity for 5000 openings per day, 250 lbs max door weight, and maximum door dimensions.

2. Safety Information

Always prioritize safety during installation and adjustment. Read all instructions thoroughly before beginning. Ensure all fasteners are securely tightened to prevent injury or damage. This product is designed for commercial use and should be installed by qualified personnel if you are unsure about any steps.

Compliance:

  • UL Listed: This door closer is UL listed for safety, ensuring it meets rigorous safety standards.
  • ADA Compliant: When properly adjusted, this door closer can meet ADA (Americans with Disabilities Act) compliance requirements, facilitating accessibility.
UL Listed and ADA Compliant certifications for the door closer

Image 2.1: The door closer is UL Listed for safety and ADA Compliant when set correctly.

3. Package Contents

Verify that all components listed below are present in your package before beginning installation. If any parts are missing or damaged, contact customer support.

  • Closer Body
  • Closer Arm Assembly
  • 1/8" Hex Wrench
  • Parallel Arm Bracket
  • Mounting Screws (various sizes for different materials)
Diagram showing all included hardware for the door closer installation

Image 3.1: All hardware included in the package, with dimensions for the closer body and arm.

4. Installation

The Lawrence LH8016 door closer can be installed in several configurations to suit various door types and opening directions. Always use the provided templates and follow the instructions carefully for optimal performance and safety.

Installation Methods:

  • Regular Arm (Pull Side): Mounted on the door frame, with the arm extending away from the door.
  • Top Jamb (Push Side): Mounted on the door frame, with the arm extending towards the door.
  • Parallel Arm (Push Side): Mounted on the door, with the arm parallel to the door frame.
Diagrams illustrating Regular, Parallel, and Top Jamb installation methods for the door closer

Image 4.1: Visual representation of the three primary installation methods: Regular, Parallel, and Top Jamb.

Interactive Installation Guide:

For a fully interactive, step-by-step 3D installation guide, download the free BILT app on your mobile device. This app provides visual instructions for all installation methods.

Person using a tablet with the BILT app for door closer installation instructions

Image 4.2: The BILT app offers interactive 3D instructions for easy installation.

Installation Video:

Video 4.1: A step-by-step installation guide for the Lawrence Commercial Door Closer, demonstrating the process for various configurations.

5. Adjustment & Operation

The LH8016 door closer features adjustable controls to fine-tune its operation for specific door requirements and user preferences. Adjustments should be made incrementally to achieve the desired closing and latching behavior.

Adjustment Points:

  • Closing Force (1-6 Levels): Adjusts the power of the door closer to match door weight and size.
  • Adjustable Backcheck: Provides hydraulic resistance to prevent the door from opening too quickly or forcefully, protecting the door and frame.
  • Delayed Closing: Allows the door to remain open for a set period before initiating the closing cycle, useful for high-traffic areas or moving large items.
  • Adjustable Closing & Latching Speeds: Controls the speed at which the door closes and the final speed at which it latches into the frame.
Diagram showing adjustment points for closing force, backcheck, delayed closing, and closing/latching speeds

Image 5.1: The door closer offers six levels of closing force, adjustable backcheck, delayed closing, and adjustable closing/latching speeds.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your Lawrence LH8016 door closer. Perform the following checks periodically:

  • Visual Inspection: Check for any signs of wear, damage, or loose components on the closer body, arm, and mounting hardware.
  • Fastener Tightness: Periodically verify that all mounting screws and adjustment screws are securely tightened. Do not overtighten.
  • Cleaning: Wipe the closer body and arm with a soft, damp cloth to remove dust and debris. Avoid abrasive cleaners.
  • Lubrication: The internal mechanisms are factory-lubricated and generally do not require additional lubrication. If unusual noises or stiffness occur, consult customer support.

7. Troubleshooting

If you encounter issues with your door closer, refer to the following common problems and solutions:

  • Door Slams Shut: The closing speed is set too fast. Adjust the closing speed valve incrementally to slow down the door's final closing motion.
  • Door Does Not Close Completely: The closing force or latching speed may be too low. Increase the closing force or adjust the latching speed valve to ensure the door fully engages with the frame. Check for obstructions or excessive friction in the door hinges.
  • Door is Difficult to Open: The closing force may be set too high. Reduce the closing force incrementally. Ensure the door closer is correctly sized for your door.
  • Oil Leakage: If you observe oil leakage, this indicates a potential internal seal failure. Discontinue use and contact customer support for assistance.
  • Unusual Noises: Squeaking or grinding noises may indicate loose components or internal issues. Inspect all fasteners and contact customer support if the noise persists.

8. Specifications

Detailed technical specifications for the Lawrence LH8016 Extra Heavy Duty Commercial Door Closer:

SpecificationDetail
Model NumberLH8016
Installation TypeScrew-In (Regular, Top Jamb, Parallel Arm)
MaterialCast Iron (Body), Aluminum (Exterior Finish)
Item Weight12.5 pounds
Product Dimensions (L x W x H)12.38 x 2.25 x 3.5 inches
Number of Pistons3
Adjustable Speeds6-Speed (Closing, Latching, Delayed Action)
ComplianceUL Listed, ADA Compliant (when properly adjusted)
UPC638455809970

9. Warranty & Support

Lawrence Hardware stands behind the quality of its products. The LH8016 door closer comes with an extended warranty to ensure your peace of mind.

Warranty Information:

This product is covered by a 30-Year Extended Warranty. For specific terms and conditions, please refer to the warranty documentation included with your purchase or contact customer support.

Lawrence Hardware logo with 'Since 1876' and 'Extended Warranty (30 Years)'

Image 9.1: Lawrence Hardware, established in 1876, offers a 30-year extended warranty on this product.

Customer Support:

For technical assistance, warranty claims, or any questions regarding your Lawrence LH8016 door closer, please contact Homebuilders Hardware:

  • Phone: 1-888-737-6515
  • Email: sales@homebuildershardware.com
UL Certification document for Lawrence Hardware swinging fire door closers

Image 9.2: UL Certification details for Lawrence Hardware door closers, including contact information for Homebuilders Hardware.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.