1. Introduction
This manual provides detailed instructions for the safe installation, operation, and maintenance of your ClimaTek 68J24 Lennox OEM Upgraded Replacement Condenser Fan Motor. This motor is designed as a direct replacement for specific Lennox HVAC condenser units, ensuring optimal performance and compatibility. Please read this manual thoroughly before attempting any installation or maintenance procedures.
The ClimaTek 68J24 is a 1/3 HP, 230V condenser fan motor, engineered to meet or exceed the specifications of the original equipment manufacturer (OEM) part. Proper installation is crucial for the longevity and efficient operation of your HVAC system.
2. Safety Information
WARNING: Electrical shock hazard. Always disconnect power to the HVAC unit at the main breaker or fuse box before installing, servicing, or removing the motor. Failure to do so can result in serious injury or death.
- Installation should only be performed by a qualified HVAC technician or a person with extensive knowledge of electrical systems and HVAC components.
- Wear appropriate personal protective equipment (PPE), including safety glasses and electrical gloves.
- Ensure all wiring connections are secure and comply with local electrical codes.
- Do not operate the motor if it appears damaged or if any wires are frayed or exposed.
- Keep hands and tools clear of moving parts, especially the fan blades, during operation.
3. Product Overview
The ClimaTek 68J24 is an upgraded replacement condenser fan motor designed for Lennox HVAC systems. It is responsible for driving the fan blades that move air across the condenser coil, facilitating heat exchange and ensuring the efficient operation of your air conditioning or heat pump unit.

Image of the ClimaTek 68J24 Lennox OEM Upgraded Replacement Condenser Fan Motor, showing its general appearance and connection points.
4. Installation
This section outlines the general steps for replacing a condenser fan motor. Specific procedures may vary based on your HVAC unit model. Always refer to your HVAC unit's service manual for detailed instructions.
4.1. Pre-Installation Checks
- Verify that the replacement motor (ClimaTek 68J24) matches the specifications of the original motor (1/3 HP, 230V).
- Ensure you have all necessary tools, including screwdrivers, wrenches, wire strippers, electrical tape, and potentially a fan blade puller.
- Confirm the power supply to the outdoor unit is completely disconnected.
4.2. Removal of Old Motor
- Remove the top panel of the condenser unit to access the fan motor and blades.
- Carefully disconnect the electrical wiring from the old motor, noting the color-coded connections. Take a photograph for reference if needed.
- Loosen the set screw(s) holding the fan blade to the motor shaft. A fan blade puller may be required if the blade is seized.
- Remove the fan blade from the motor shaft.
- Unbolt or unmount the old motor from its housing.
4.3. Installation of New Motor
- Mount the new ClimaTek 68J24 motor into the condenser unit housing, securing it with the appropriate bolts or screws.
- Slide the fan blade onto the new motor shaft. Ensure the blade is positioned correctly for optimal airflow and tighten the set screw(s) securely.
- Wiring Connections: The ClimaTek 68J24 is typically a 3-wire motor. Connect the wires according to the original wiring configuration. Common connections are:
- Black: Line/Run
- White: Common
- Orange/Purple (or other color): Capacitor (Herm or Fan terminal on a dual capacitor)
- Fan Rotation: After initial wiring, briefly restore power to check the fan's rotation direction. The fan should pull air up and out of the condenser unit. If the rotation is incorrect, reverse the connections of the two capacitor wires (e.g., swap orange and purple wires if applicable) to change the direction. Remember to disconnect power before making any wiring changes.
- Secure all wiring with appropriate connectors and ensure no wires are pinched or exposed.
- Replace the top panel of the condenser unit.
4.4. Post-Installation
- Restore power to the HVAC unit.
- Test the unit's operation to ensure the fan motor runs smoothly and quietly.
- Monitor the unit for any unusual noises or vibrations.
5. Operating Instructions
The ClimaTek 68J24 condenser fan motor operates automatically as part of your HVAC system's cooling or heating cycle. Once properly installed, it requires no manual intervention for operation. The motor will engage when the thermostat calls for cooling or heating, driving the condenser fan to dissipate heat from the outdoor unit.
6. Maintenance
Regular maintenance helps ensure the longevity and efficiency of your condenser fan motor and overall HVAC system.
- Annual Inspection: Have a qualified technician inspect the motor and fan assembly annually.
- Cleaning: Periodically clean any debris (leaves, dirt, etc.) from around the condenser unit and fan blades. Ensure power is disconnected before cleaning.
- Check for Vibrations/Noise: Listen for any unusual noises or excessive vibrations during operation. These could indicate a problem with the motor bearings or fan blade balance.
- Wiring Check: Ensure all electrical connections remain tight and free from corrosion.
This motor is typically sealed and does not require lubrication.
7. Troubleshooting
If your condenser fan motor is not operating as expected, consider the following common issues and solutions. Always disconnect power before inspecting the unit.
- Motor Not Starting:
- Check for power supply to the unit.
- Inspect wiring connections for looseness or corrosion.
- Test the capacitor. A faulty capacitor is a common cause of motor failure to start.
- Check for obstructions preventing the fan blade from turning.
- Unusual Noise or Vibrations:
- Inspect fan blades for damage or imbalance.
- Check if the motor mounting bolts are loose.
- Listen for grinding or squealing, which may indicate worn motor bearings.
- Motor Overheating:
- Ensure proper airflow around the condenser unit. Clear any debris.
- Verify the fan blade is rotating in the correct direction.
- Check for proper voltage supply.
If troubleshooting steps do not resolve the issue, contact a qualified HVAC technician for further diagnosis and repair.
8. Specifications
| Feature | Specification |
|---|---|
| Brand | ClimaTek |
| Model Number | 68J24 (OEM Rplm Lennox # 68J24) |
| Voltage | 230 Volts |
| Horsepower | 0.33 HP (1/3 HP) |
| UPC | 351801310592 |
| Manufacturer | Lennox (as OEM replacement) |
| Number of Items | 1 |
9. Warranty Information
Specific warranty details for the ClimaTek 68J24 motor are not provided in this manual. For information regarding warranty coverage, terms, and conditions, please refer to the product packaging, the seller's website, or contact ClimaTek customer support directly. Keep your proof of purchase for any warranty claims.
10. Customer Support
If you have questions about the installation, operation, or troubleshooting of your ClimaTek 68J24 condenser fan motor, please contact the seller or manufacturer for assistance. When contacting support, have your product model number (68J24) and proof of purchase readily available.