1. Introduction

This manual provides essential information for the safe and correct installation, operation, and maintenance of your Urmet 786/1A Intercom Power Supply. Please read these instructions carefully before installation and retain them for future reference. This device is designed to provide power to Urmet intercom systems.

2. Safety Information

  • Professional Installation Required: Installation and wiring must be performed by qualified personnel in accordance with all local electrical codes and regulations.
  • Voltage Warning: This device operates with 230V AC. Always disconnect the main power supply before performing any installation, maintenance, or troubleshooting. Failure to do so can result in electric shock, injury, or death.
  • Indoor Use Only: This power supply is designed for indoor use in dry environments. Do not expose it to moisture, rain, or extreme temperatures.
  • Ventilation: Ensure adequate ventilation around the unit to prevent overheating. Do not cover the power supply.
  • Grounding: Ensure the unit is properly grounded as per electrical standards.

3. Product Overview

The Urmet 786/1A is a dedicated power supply unit for Urmet intercom systems. It converts the main AC voltage to the required low voltage for the intercom components. The unit is designed for reliable and stable power delivery.

Label showing Urmet Intercom Power Supply model 786/1A with 28VA-230V specifications.

Figure 1: Product label for Urmet Intercom Power Supply. This label indicates the model number 786/1A and its electrical specifications: 28VA power supply operating at 230V. It also lists other compatible models like 786/14A and 786/38A with different power ratings.

4. Setup and Installation

Warning: Ensure the main power supply is disconnected before beginning installation.

  1. Mounting: Mount the power supply unit in a secure, well-ventilated location, away from direct heat sources or moisture.
  2. Wiring Connections: Connect the 230V AC main power input to the designated terminals on the power supply. Ensure correct polarity and secure connections.
  3. Intercom System Connection: Connect the output terminals of the power supply to the Urmet intercom system according to the specific wiring diagram provided with your intercom unit. Refer to the intercom system's manual for detailed wiring instructions.
  4. Verify Connections: Double-check all wiring connections for security and correctness before restoring power.
  5. Power On: Once all connections are verified, restore the main power supply. The intercom system should now be powered.

5. Operating Instructions

The Urmet 786/1A Intercom Power Supply operates automatically once correctly installed and connected to the main power. It continuously provides the necessary power to your Urmet intercom system. There are no user-adjustable controls on the power supply unit itself. Operation of the intercom system is managed through the intercom's internal controls and components.

6. Maintenance

The Urmet 786/1A power supply requires minimal maintenance. Follow these guidelines:

  • Cleaning: Periodically clean the exterior of the unit with a dry, soft cloth. Do not use liquid cleaners or solvents.
  • Connection Checks: Occasionally, with the power disconnected, inspect the wiring connections to ensure they remain secure.
  • Ventilation: Ensure that the ventilation openings are not obstructed by dust or debris.
  • Power Disconnection: Always disconnect the main power supply to the unit before performing any inspection or maintenance.

7. Troubleshooting

If your intercom system is not functioning correctly, consider the following troubleshooting steps:

  • No Power to Intercom:
    • Check if the main power supply to the unit is active.
    • Verify that all input and output wiring connections to the power supply are secure and correctly installed.
    • Ensure no circuit breakers have tripped.
  • Intermittent Operation:
    • Inspect for loose wiring connections at both the power supply and the intercom unit.
    • Ensure the power supply is not overheating due to inadequate ventilation.
  • System Malfunction: If the power supply appears to be working but the intercom system is still not functioning, consult the intercom system's specific manual for troubleshooting steps related to the intercom unit itself.
  • Professional Assistance: If issues persist after performing these checks, contact a qualified electrician or Urmet technical support for assistance. Do not attempt to repair the power supply unit yourself.

8. Specifications

FeatureSpecification
BrandURMET
Model Name786/1A
Input Voltage230 Volts (AC)
Output Power28 VA (Volt-Ampere) / 12 Watts
Current Rating1 A
Compatible DevicesUrmet Intercom Systems
Form FactorATX (Note: This may refer to internal component form factor, not external casing.)
Cooling MethodAir
Number of Connectors1

9. Warranty and Support

For information regarding warranty coverage, technical support, or service, please refer to the documentation provided with your purchase or contact your Urmet dealer or the official Urmet customer service. Keep your proof of purchase for warranty claims.

© 2023 Urmet. All rights reserved.

Related Documents - 786/1A

Preview ZJEDNODUŠENÝ NÁVOD: ZAPOJENÍ SYSTÉMU URMET 1736
Zjednodušený návod pro zapojení a konfiguraci systémů videovrátných a audio vrátných URMET řady 1736. Obsahuje základní schéma zapojení soupravy 1736/501, paralelní zapojení více videotelefonů a příklad rozšíření systému s více tlačítky a byty. Podrobné informace o nastavení DIP přepínačů pro různé konfigurace.
Preview Manual del Sistema Urmet 2Voice: Instalación y Operación
Guía completa del sistema de videoportero Urmet 2Voice, cubriendo instalación, configuración, características y funcionamiento. Aprenda a configurar y gestionar el sistema de comunicación de su edificio.
Preview Urmet Alpha: Modulární digitální tlačítkový panel
Modulární digitální tlačítkový panel Urmet Alpha pro systémy Urmet. Podrobné informace o funkcích, snadné montáži, flexibilitě a programování.
Preview Urmet 1131 Electronic Call Intercom System: Wiring Diagrams and Notes
Comprehensive guide to the Urmet 1131 electronic call intercom system, featuring terminal identification, important installation notes, and detailed wiring diagrams for 1-way and 2-entrance Urmet 1133 systems.
Preview Urmet VOG5 (IP) Handsfree Monitor: Getting Started Guide
A quick start guide for the Urmet VOG5 (IP) Handsfree Monitor, providing video tutorials on answering calls, opening doors/gates, managing notifications, and customizing settings.
Preview Urmet Miro 1750/5 and 1750/6 Video Door Phone Installation and User Manual
Comprehensive installation and user guide for the Urmet Miro 1750/5 (Black) and 1750/6 (White) 2Voice video door phone system. Includes configuration, wiring, button functions, and feature setup.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.