Ebara AGA 1.00 M

EBARA Serie AGA 1.00 M Monophase Self-Priming Cast Iron Electric Pump User Manual

Model: AGA 1.00 M | Manufacturer: Ebara

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EBARA Serie AGA 1.00 M Monophase Self-Priming Cast Iron Electric Pump. Please read this manual thoroughly before using the product and keep it for future reference. Adherence to these instructions will ensure optimal performance and extend the lifespan of your pump.

2. Safety Instructions

Always observe the following safety precautions to prevent personal injury or damage to the pump.

  • Electrical Safety: Ensure the pump is connected to a properly grounded electrical outlet. Do not operate the pump with damaged cables or plugs. Disconnect power before any maintenance or inspection.
  • Water Safety: Do not operate the pump dry. Ensure the pump is always submerged or primed with water before starting. Protect the pump from freezing temperatures.
  • Installation: Install the pump on a stable, level surface. Ensure adequate ventilation around the motor. All connections must be watertight.
  • Operation: Do not touch moving parts. Keep hands and clothing clear of the pump during operation.
  • Maintenance: Only qualified personnel should perform repairs. Use only genuine EBARA replacement parts.

3. Product Overview

The EBARA Serie AGA 1.00 M is a robust monophase self-priming electric pump constructed from cast iron, designed for reliable water transfer applications. Its self-priming capability simplifies initial setup.

3.1 Key Features

  • Monophase electric pump
  • Self-priming design
  • Durable cast iron construction
  • Suitable for various water transfer tasks

3.2 Product Images

EBARA Serie AGA 1.00 M Monophase Self-Priming Electric Pump

Figure 1: Frontal view of the EBARA Serie AGA 1.00 M electric pump. This image displays the pump's main body, motor housing, and electrical connection box, highlighting its robust blue cast iron construction.

EBARA Serie AGA 1.00 M Electric Pump with Dimensions

Figure 2: Side view of the EBARA Serie AGA 1.00 M electric pump, illustrating its physical dimensions. The image shows the length (44cm), width (25cm), and height (21cm) of the pump, providing a clear understanding of its size for installation planning.

4. Setup

Proper installation is crucial for the pump's performance and longevity. Follow these steps carefully:

  1. Mounting: Securely mount the pump on a firm, level, and vibration-free surface. Ensure it is protected from direct weather exposure if installed outdoors.
  2. Piping Connections: Connect the suction and discharge pipes. Use appropriate fittings and ensure all connections are airtight to prevent air leaks, which can affect self-priming. The suction pipe should be as short and straight as possible.
  3. Electrical Connection: Connect the pump to a 220 Volt monophase power supply. Ensure the electrical circuit is protected by a suitable circuit breaker and residual current device (RCD). Wiring should be performed by a qualified electrician in accordance with local regulations.
  4. Priming (Initial Start-up): As this is a self-priming pump, it will automatically evacuate air from the suction line. However, for the very first start-up or after extended periods of disuse, it is recommended to fill the pump casing with water through the priming port (if available) to accelerate the priming process.

5. Operating Instructions

Once installed and primed, operating the EBARA Serie AGA 1.00 M pump is straightforward:

  1. Starting the Pump: Ensure all valves in the suction and discharge lines are open. Switch on the electrical power supply to the pump. The pump will start and begin to draw water.
  2. Monitoring: Observe the pump during the first few minutes of operation. Check for any unusual noises, vibrations, or leaks. Ensure a steady flow of water is established.
  3. Stopping the Pump: To stop the pump, simply switch off the electrical power supply. Close any necessary valves to prevent backflow or siphoning.
  4. Extended Use: For continuous operation, periodically check the pump's temperature and performance. Avoid running the pump dry, as this can cause severe damage.

6. Maintenance

Regular maintenance ensures the longevity and efficiency of your EBARA pump.

  • Routine Checks: Periodically inspect the pump for any signs of wear, corrosion, or leaks. Check electrical connections for tightness and integrity.
  • Cleaning: Keep the exterior of the pump clean and free from debris. If the pump is used in dirty water applications, regularly check and clean the impeller and pump casing for blockages.
  • Winterization: In areas prone to freezing temperatures, drain the pump completely and store it in a frost-free environment to prevent damage from ice expansion.
  • Seal Replacement: If water leakage is observed from the shaft seal area, it may indicate a worn seal. This should be replaced by a qualified technician.

7. Troubleshooting

This section addresses common issues you might encounter with your pump.

ProblemPossible CauseSolution
Pump does not startNo power supply; Motor overload; Faulty switch/wiring.Check power connection and circuit breaker. Allow motor to cool if overloaded. Inspect wiring.
Pump runs but no water flowPump not primed; Air leak in suction line; Suction lift too high; Impeller clogged.Ensure pump is primed. Check suction line for leaks. Verify suction lift is within specifications. Clean impeller.
Reduced water flow/pressurePartial blockage in pipes/impeller; Worn impeller/diffuser; Air in system.Inspect and clear blockages. Check for air leaks. Consider professional inspection for worn parts.
Excessive noise or vibrationCavitation (air in water); Loose mounting; Worn bearings; Foreign object in pump.Check for air leaks in suction. Secure mounting. Inspect for foreign objects. Contact service for worn bearings.

If you are unable to resolve an issue using this guide, please contact a qualified technician or EBARA customer support.

8. Specifications

Detailed technical specifications for the EBARA Serie AGA 1.00 M electric pump:

BrandEbara
Model Number1100100000
Product Dimensions (L x W x H)44 cm x 25 cm x 21 cm
Product Weight14.22 kg
MaterialCast Iron, Brass
Power SourceElectric Cable
Voltage220 Volts
Maximum Lifting Height68 Meters
ColorTurquoise
StyleClassic

9. Warranty and Support

For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized EBARA dealer. For technical support or service inquiries, please reach out to the manufacturer or your product supplier. Ensure you have your model number (AGA 1.00 M) and serial number (if applicable) ready when contacting support.

Manufacturer: Ebara

Related Documents - AGA 1.00 M

Preview EBARA JE(S)(X), AG(..) Surface Pumps - Operating and Maintenance Manual
Comprehensive operating and maintenance manual for EBARA JE(S)(X), AG(..) series surface pumps. Includes technical specifications, installation guidelines, usage instructions, and safety precautions.
Preview EBARA EVMS 1-90 Vertical Multistage Pumps Product Catalogue
Comprehensive product catalogue for EBARA EVMS 1-90 vertical multistage pumps, detailing features, applications, performance ranges, construction, and global sales network. Learn about innovative hydraulic solutions, reliability, and technical specifications.
Preview EBARA 1GP Automatic Pressure Booster Sets - Operating and Maintenance Manual
Comprehensive operating and maintenance manual for EBARA 1GP Automatic Pressure Booster Sets. Covers installation, operation, troubleshooting, and safety guidelines for various models.
Preview Manuale di Uso e Manutenzione Elettropompe Ebara Optima M
Questa guida fornisce istruzioni essenziali per l'installazione, l'uso e la manutenzione sicura ed efficiente delle elettropompe sommerse Ebara Optima M, assicurando prestazioni ottimali.
Preview EBARA DKE Series Submersible Motor-Driven Pumps - Operating and Maintenance Manual
Comprehensive operating and maintenance manual for EBARA DKE series submersible motor-driven pumps. Covers installation, operation, safety, troubleshooting, and maintenance for reliable performance.
Preview Manual de Instruções Ebara Bombas Submersíveis Trituradoras TSBT, BST, DG
Este manual fornece instruções detalhadas para a instalação, operação e manutenção das bombas submersíveis trituradoras Ebara modelos TSBT, BST e DG, garantindo desempenho seguro e eficiente.