Ebara 1100090000

EBARA AGA 0.75 M Self-Priming Pump User Manual

Model: 1100090000

1. Product Overview

The EBARA AGA 0.75 M is a robust single-phase self-priming electric pump constructed from cast iron, designed for efficient clean water transfer. Its applications include domestic water pressure boosting, small-scale garden irrigation, vehicle washing, and general water movement tasks.

EBARA AGA 0.75 M Single-Phase Self-Priming Cast Iron Pump

This image shows the EBARA AGA 0.75 M self-priming pump, featuring a blue cast iron body and an integrated electric motor with a black terminal box on top. The pump has visible inlet and outlet connections.

2. Setup and Installation

Proper installation is crucial for the pump's performance and longevity. Follow these general guidelines:

  1. Placement: Install the pump in a dry, well-ventilated area, protected from frost and direct sunlight. Ensure a stable, level surface to minimize vibration.
  2. Pipe Connections: Connect the suction pipe to the pump's G1 suction port and the delivery pipe to the G1 delivery port. Ensure all connections are airtight to prevent air ingress, which can affect priming. Use appropriate sealants and fittings.
  3. Electrical Connection: The pump operates on 230 V ± 10% 50 Hz single-phase power. Connect the pump to a suitable electrical supply according to local regulations. Ensure the circuit is protected by a permanent capacitor and an automatic reset thermal-amperometric protection device.
  4. Priming: As a self-priming pump, it can draw water from a certain depth (up to 8m). Before initial startup, fill the pump body completely with clean water through the priming port until it overflows. This ensures the pump can establish suction.

3. Operating Instructions

Once installed and primed, the pump is ready for operation:

  • Initial Start-up: After priming, switch on the power supply. The pump should start drawing water and build pressure.
  • Monitoring: Observe the pump during operation. Listen for unusual noises and check for leaks. Ensure consistent water flow and pressure.
  • Continuous Operation: The pump is designed for continuous duty within its specified operating limits. Avoid running the pump dry, as this can cause damage to the mechanical seal.
  • Shut-down: To stop the pump, simply switch off the power supply.

4. Maintenance

Regular maintenance helps ensure the longevity and efficient operation of your pump:

  • Regular Inspection: Periodically check all connections for leaks and ensure the pump is securely mounted. Inspect the power cable for any damage.
  • Cleaning: Keep the pump exterior clean and free from debris. Ensure the motor's ventilation fins are not obstructed to prevent overheating.
  • Winterization (if applicable): In areas prone to freezing temperatures, drain the pump completely to prevent damage from ice expansion. Disconnect pipes and open drain plugs. Store the pump in a frost-free environment if possible.
  • Mechanical Seal: The mechanical seal is a wear part. If persistent leaks occur from the shaft area, the seal may need replacement by a qualified technician.

5. Troubleshooting

This section addresses common issues you might encounter:

ProblemPossible CauseSolution
Pump does not startNo power supply; Motor overload protection tripped; Seized impellerCheck power connection and circuit breaker; Allow motor to cool and reset protection; Contact qualified technician.
Pump runs but no water flowPump not primed; Air leak in suction line; Suction lift too high; Clogged suction filterRe-prime the pump; Check all suction connections for leaks; Ensure suction depth is within 8m limit; Clean suction filter.
Low pressure or reduced flowPartial air leak; Partially clogged impeller/pipes; Worn impeller or mechanical sealCheck suction line for small leaks; Inspect and clean impeller/pipes; Contact qualified technician for inspection.
Excessive noise or vibrationCavitation (air in water); Loose mounting; Bearing wearEnsure proper priming and no air leaks; Securely fasten pump; Contact qualified technician.

6. Specifications

FeatureDetail
ManufacturerEbara
Model Number1100090000
MaterialCast Iron
Power SourceCorded Electric
Voltage230 Volts (AC)
Maximum Operating Pressure6 bar
Maximum Liquid Temperature45 °C
Maximum Suction Depth8 m
Suction ConnectionG1
Delivery ConnectionG1
Motor EfficiencyIE2 and IE3 (from 0.75 kW)
Insulation ClassF
Protection DegreeIP44
Package Dimensions40.5 x 18.5 x 18 cm
Item Weight12.5 kilograms
Batteries IncludedNo
Batteries RequiredNo
Spare Parts AvailabilityInformation unavailable

7. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your authorized Ebara dealer. Information regarding spare parts availability is currently not provided in the product specifications.

Related Documents - 1100090000

Preview EBARA JE(S)(X), AG(..) Surface Pumps - Operating and Maintenance Manual
Comprehensive operating and maintenance manual for EBARA JE(S)(X), AG(..) series surface pumps. Includes technical specifications, installation guidelines, usage instructions, and safety precautions.
Preview EP BASIC 1-2 Electronic Control Panel for Single or Three-Phase Pumps
The EP BASIC 1-2 is an electronic control panel designed for managing one or two single-phase or three-phase pumps. It offers features like dry-running protection, thermal overload protection, and alarm signaling, suitable for clean water and wastewater systems. The panel is compact, easy to install and program, and available with various accessories and special configurations.
Preview EP BASIC 1-2 Electronic Control Panel for 1 or 2 Single-Phase or Three-Phase Pumps
The EP BASIC 1-2 is an electronic control panel designed for managing one or two single-phase or three-phase pumps. It offers features like anti-seizing, dry-run protection, and overload protection, with options for remote control and advanced accessories. Suitable for clean and wastewater applications.
Preview EBARA CDA Series Centrifugal Pumps - Technical Specifications and Performance Data
Comprehensive technical data, performance curves, dimensions, and motor specifications for EBARA CDA series centrifugal pumps (50Hz). Includes detailed information on materials, mechanical seals, bearings, and packing for various models.
Preview EBARA EVMS 1-90 Vertical Multistage Pumps Product Catalogue
Comprehensive product catalogue for EBARA EVMS 1-90 vertical multistage pumps, detailing features, applications, performance ranges, construction, and global sales network. Learn about innovative hydraulic solutions, reliability, and technical specifications.
Preview EBARA 1GP Automatic Pressure Booster Sets - Operating and Maintenance Manual
Comprehensive operating and maintenance manual for EBARA 1GP Automatic Pressure Booster Sets. Covers installation, operation, troubleshooting, and safety guidelines for various models.