Detex V40-EB-CD-628-99-36

Detex V40-EB-CD-628-99-36 Rim Exit Device User Manual

Model: V40-EB-CD-628-99-36

1. Introduction and Overview

The Detex V40-EB-CD-628-99-36 Rim Exit Device is a heavy-duty, Grade 1 panic and fire exit alarm system designed for secure and reliable emergency egress. This mechanical exit device features cylinder dogging, allowing for temporary hold-open functionality, and is suitable for various door applications requiring robust security and compliance with safety standards. It provides an audible alarm upon activation to alert personnel during an emergency exit.

Detex V40-EB-CD-628-99-36 Rim Exit Device

Figure 1: Detex V40-EB-CD-628-99-36 Rim Exit Device. This image displays the main components and satin aluminum finish of the exit device.

2. Safety Information

Please read and understand all safety instructions before installing or operating the Detex V40-EB-CD-628-99-36 Rim Exit Device. Failure to follow these instructions may result in property damage, injury, or improper device function.

  • Professional Installation: Ensure the device is installed by qualified personnel in accordance with all local building codes, fire safety regulations, and the provided installation instructions.
  • Regular Inspection: Periodically inspect the device for proper function, wear, and damage. Any issues should be addressed immediately.
  • Unobstructed Path: Always ensure the exit path is clear and free from obstructions to allow for safe and immediate egress.
  • Battery Safety: Use only the specified 9V alkaline battery. Replace batteries as recommended and dispose of used batteries responsibly.

3. Package Contents

Verify that all components are present and undamaged upon opening the package:

  • Detex V40-EB-CD-628-99-36 Rim Exit Device
  • Mounting Hardware (screws, bolts, etc.)
  • Installation Template
  • User Manual (this document)
  • 9V Alkaline Battery (may be included or sold separately)

4. Setup and Installation

This section provides general guidelines for the installation of the Detex V40-EB-CD-628-99-36 Rim Exit Device. Always refer to the detailed installation instructions and template provided with the product for specific steps and measurements.

  1. Door Preparation: Ensure the door meets the specified dimensions: 36 inches width, 84 inches height, and a thickness between 1 3/4 inches to 2 1/4 inches. The device fits stile widths of 3 1/2 inches.
  2. Template Application: Affix the provided installation template to the door, ensuring it is level and correctly positioned according to the desired mounting height.
  3. Drilling Holes: Carefully drill all necessary holes as indicated by the template. Use appropriate drill bits for the door material.
  4. Device Mounting: Position the exit device on the door and secure it using the provided mounting hardware. Ensure all screws and bolts are tightened securely, but do not overtighten.
  5. Strike Plate Installation: Install the strike plate on the door frame, aligning it precisely with the latch bolt of the exit device.
  6. Battery Installation: Open the battery compartment (typically located on the device housing) and insert one 9V alkaline battery, observing correct polarity. Close the compartment securely.
  7. Functionality Test: After installation, perform several tests to ensure the device operates smoothly, the latch bolt retracts fully, and the alarm sounds correctly upon activation.

Note: This device is non-handed and can be installed on both left-hand and right-hand doors without modification.

5. Operating Instructions

The Detex V40-EB-CD-628-99-36 is designed for straightforward operation during emergency and non-emergency situations.

  • Emergency Egress: To exit, firmly push the panic bar. The latch bolt will retract, allowing the door to open. Simultaneously, the integrated alarm will sound at approximately 100 decibels, signaling an exit event.
  • Cylinder Dogging: For periods when the door needs to remain unlocked and allow free passage without the alarm sounding, the cylinder dogging feature can be engaged. Insert the appropriate key into the cylinder on the exterior side of the device and turn it to retract and hold the latch bolt in the open position. To disengage dogging and restore normal panic operation, turn the key in the opposite direction.
  • Alarm Reset: The alarm will typically reset automatically once the panic bar is released and the door is closed, or it may require a key turn in the cylinder to silence, depending on the specific configuration. Consult the detailed product documentation for alarm reset procedures.

6. Maintenance

Proper maintenance ensures the longevity and reliable operation of your Detex exit device.

  • Cleaning: Clean the exterior surfaces of the device regularly with a soft, dry cloth. Avoid abrasive cleaners or solvents that could damage the finish.
  • Fastener Check: Periodically check all mounting screws and bolts for tightness. Retighten any loose fasteners to ensure the device remains securely attached to the door.
  • Functional Test: Conduct a full functional test of the device monthly. Activate the panic bar to ensure smooth operation and verify that the alarm sounds as expected.
  • Battery Replacement: Replace the 9V alkaline battery annually, or immediately if a low battery indicator is present and activated, or if the alarm sounds weak or fails to sound.
  • Lubrication: Apply a small amount of silicone-based lubricant to moving parts, such as the latch bolt and internal mechanisms, as needed to maintain smooth operation. Do not over-lubricate.

7. Troubleshooting

Refer to the following table for common issues and their potential solutions.

Problem Possible Cause Solution
Alarm not sounding Dead or low 9V battery; incorrect battery installation; alarm disarmed. Replace 9V battery; ensure correct polarity; check alarm arming status.
Device not latching Obstruction in door frame or latch bolt path; misaligned strike plate; damaged latch bolt. Clear obstructions; adjust strike plate alignment; inspect and replace damaged components.
Panic bar stiff or difficult to push Lack of lubrication; bent or damaged internal components; debris. Clean and lubricate moving parts; inspect for damage and replace if necessary.
Door not opening when panic bar is pushed Latch bolt not fully retracting; door frame misalignment; external obstruction. Check latch bolt movement; inspect door and frame for alignment; remove obstructions.

If troubleshooting steps do not resolve the issue, contact Detex customer support for assistance.

8. Specifications

Brand Detex
Model V40-EB-CD-628-99-36
Product Type Rim Exit Device, Panic and Fire Exit Alarm
Grade 1
Finish Satin Aluminum
Compatible Door Width 36 inches
Compatible Door Height 84 inches
Compatible Stile Width 3 1/2 inches
Compatible Door Thickness 1 3/4 inches to 2 1/4 inches
Handing Non-Handed
Power Source 1 x 9V Alkaline Battery
Audible Noise 100 Decibels
Mounting Type Door Mount
Standards Compliance ANSI/BHMA A156.3, cULus Listed, NFPA 80 & 101, UBC 97
Item Weight 14 Pounds
Product Dimensions (L x W x H) 84"L x 36"W x 84"H

9. Warranty and Support

For detailed warranty information, technical assistance, or to purchase replacement parts, please contact Detex customer service directly. You can find contact information and additional resources on the official Detex website.

Detex Official Website: www.detex.com

© 2023 Detex Corporation. All rights reserved.

This manual is subject to change without notice.