AlveyTech W52RA76-290018
AlveyTech OKIN W52RA76-290018 Lift Chair Power Supply/Transformer User Manual
Model: W52RA76-290018 (LM5-6501)
1. Product Overview
The AlveyTech OKIN W52RA76-290018 Lift Chair Power Supply/Transformer is designed as a direct replacement for earlier OKIN SP2-B and SP2-B2 transformer models. It provides reliable power for a wide range of lift chair models from various manufacturers, including Golden and Pride.
Key features include:
- Direct replacement for OKIN SP2-B & SP2-B2 transformers.
- Equipped with a 9-volt emergency backup system to return the lift chair to an egress position during power outages. (Note: 9-volt batteries are not included and must be purchased separately.)
- Designed with a tighter plug-in aperture for enhanced cord security, preventing accidental disconnections.

Figure 1: Top view of the AlveyTech OKIN W52RA76-290018 Power Supply, showing the DC Power indicator light.
2. Setup and Installation
This power supply is designed for straightforward installation. Please follow these steps:
- Unpack the Power Supply: Carefully remove the power supply from its packaging.
- Insert Backup Batteries (Optional but Recommended): Locate the battery compartment (typically on the underside) and insert two standard 9-volt batteries. These batteries provide emergency power for a single return to egress position during a power outage.
- Connect Power Cords:
- Connect the AC input cord (not included) to the power supply's AC input port and then to a standard 115VAC, 50/60HZ wall outlet.
- Connect the DC output cord (not included) from the power supply's DC output port to your lift chair's power input.
Note: Power cords are not included with this transformer and must be purchased separately. The plug-in aperture for the transformer cable is designed to hold the male plug securely, requiring a firm push to insert or remove. This is a safety feature to prevent accidental disconnections.
- Verify Connection: Ensure all connections are secure. The DC Power indicator light on the top of the unit should illuminate when properly connected to a power source.

Figure 2: AC Input Port for connecting to wall outlet.

Figure 3: DC Output Connector for connecting to lift chair.
3. Operation
Once properly installed and connected, the AlveyTech OKIN W52RA76-290018 power supply will provide continuous 24VDC power to your compatible lift chair. The lift chair's original hand control or integrated controls will function as usual, drawing power from this unit.
In the event of a main power interruption, the installed 9-volt backup batteries will temporarily supply enough power for one emergency operation cycle, allowing the lift chair to return to a safe egress position.
4. Maintenance
The AlveyTech OKIN W52RA76-290018 power supply requires minimal maintenance. To ensure optimal performance and longevity:
- Keep Clean: Periodically wipe the exterior of the unit with a dry, soft cloth to remove dust and debris.
- Ensure Ventilation: Do not cover the unit or place it in an enclosed space where airflow is restricted.
- Check Connections: Regularly inspect all power cord connections to ensure they are secure and free from damage.
- Battery Replacement: If using the 9-volt backup feature, replace the batteries periodically (e.g., annually) or after they have been used during a power outage to ensure emergency functionality.
- Avoid Moisture: Keep the power supply away from water and excessive humidity.
5. Troubleshooting
If you experience issues with your lift chair's power, refer to the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Lift chair does not operate. | No power to the unit; loose connections; faulty power cord. |
|
| Lift chair operates intermittently. | Loose connections; power fluctuations. |
|
| Emergency backup not working. | No 9-volt batteries installed; dead 9-volt batteries. |
|
If the problem persists after attempting these solutions, please contact AlveyTech customer support or a qualified technician.
6. Technical Specifications
| Specification | Value |
|---|---|
| Model | W52RA76-290018 |
| Version Code | JLDP.10.014.000 |
| Input | 115VAC, 50/60HZ |
| Output | 24VDC, 45W |
| Backup Batteries | 2 x 9 volt (not included) |
| Item Weight | 10.24 ounces (290.3 grams) |
| Product Dimensions (LxWxH) | 12 x 3 x 2.25 inches (30.48 x 7.62 x 5.72 cm) |
| Color | Black |
| Connectivity Technology | Proprietary connector |
| Mounting Type | Tabletop Mount |

Figure 4: Product dimensions for the power supply.
7. Compatibility
This power supply is compatible with a wide range of lift chair models that previously used the OKIN SP2-B or SP2-B2 transformer units. Known compatible brands include:
- Golden lift chairs
- Mega Motion lift chairs
- Pride lift chairs
It is designed to retrofit seamlessly into these models. If you are unsure about compatibility, please consult your lift chair's manual or contact the manufacturer.
8. Safety Information
WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Always ensure the power supply is disconnected from the wall outlet before performing any maintenance or connection adjustments. Do not attempt to open or repair the unit yourself. Refer all servicing to qualified personnel.
9. Warranty and Support
For warranty information and customer support, please refer to the documentation provided with your purchase or visit the official AlveyTech website. You can also visit the AlveyTech Store on Amazon for additional resources and contact details.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.