1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Atosa MCF8703 Two Glass Door Commercial Freezer. Please read this manual thoroughly before using the appliance and retain it for future reference.
The Atosa MCF8703 is a bottom mount commercial merchandiser freezer designed for commercial use, offering 47.1 cubic feet of storage capacity with two glass doors. It features an efficient refrigeration system, LED lighting, and a Dixell digital temperature control system.
2. Safety Information
Important: Always follow basic safety precautions when using this appliance to reduce the risk of fire, electric shock, or injury.
- Ensure the freezer is connected to a properly grounded electrical outlet with the correct voltage (115 Volts).
- Do not operate the freezer with a damaged power cord or plug.
- Keep ventilation openings clear of obstructions.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Only qualified personnel should perform repairs or maintenance.
- Unplug the unit before cleaning or performing any maintenance.
3. Setup and Installation
3.1 Unpacking
Carefully remove all packaging materials. Inspect the freezer for any shipping damage. Report any damage immediately to the carrier and your supplier.
3.2 Placement
- Place the freezer on a strong, level surface capable of supporting its weight (approximately 462 pounds when empty, plus contents).
- Ensure adequate air circulation around the unit. Maintain a minimum of 4 inches (10 cm) clearance from walls and other appliances to allow for proper ventilation of the bottom-mounted compressor.
- Avoid direct sunlight or proximity to heat-generating appliances.

Figure 1: Front view of the Atosa MCF8703 commercial freezer.
3.3 Caster Installation
The Atosa MCF8703 comes with pre-installed casters for easy mobility. Ensure all casters are securely locked once the unit is in its final position to prevent accidental movement.

Figure 2: Detail of the bottom-mounted compressor area and pre-installed casters.
3.4 Shelf Installation and Adjustment
The freezer is equipped with 8 pre-installed adjustable shelves. To adjust shelf height:
- Empty the shelf of all contents.
- Lift the shelf slightly and remove it from the shelf clips.
- Reposition the shelf clips to the desired height on the vertical shelf supports. Ensure clips are level.
- Place the shelf back onto the clips, ensuring it is stable.
Each shelf has a loading capacity of 155 lbs. Do not exceed this weight limit.

Figure 3: Interior view showing adjustable shelves.
3.5 Electrical Connection
Connect the freezer to a dedicated 115 Volt, 60 Hz, single-phase grounded electrical outlet. Do not use extension cords or adapter plugs. Ensure the circuit is protected by a fuse or circuit breaker of appropriate amperage.
3.6 Initial Startup
After placement and electrical connection, allow the freezer to stand for at least 2 hours before plugging it in. This allows refrigerants to settle. Once plugged in, allow the unit to operate for 24 hours empty to reach its stable operating temperature before loading with products.
4. Operation
4.1 Temperature Control
The freezer is equipped with a Dixell digital temperature control system. The digital display shows the current internal temperature. To adjust the temperature:
- Press the 'SET' button once. The current set point temperature will flash.
- Use the 'UP' or 'DOWN' arrow buttons to adjust the temperature to your desired setting.
- Press the 'SET' button again to confirm the new setting.
The recommended operating temperature range for this freezer is typically between -10°F to 0°F (-23°C to -18°C).
4.2 Loading Products
Ensure products are loaded evenly on the shelves, respecting the 155 lbs per shelf capacity. Do not block the internal air vents, as this can impede air circulation and cooling efficiency.

Figure 4: Interior view of the freezer with products loaded.
4.3 Door Features
- Self-Closing Doors: The glass doors are designed to self-close to maintain internal temperature and energy efficiency.
- Stay-Open Feature: The doors can be held open at a certain angle (e.g., 90 degrees) for easier loading or cleaning.
- Door Lock: A standard safety door lock is integrated for securing contents.
- LED Lighting: The interior display system uses LED lighting for clear visibility of products.

Figure 5: Freezer with both glass doors open, showing interior and LED lighting.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your freezer. Always unplug the unit before performing any maintenance.
5.1 Cleaning the Interior
- Remove all products and shelves.
- Clean the interior surfaces with a mild detergent and warm water. Rinse thoroughly with clean water and dry completely.
- Do not use abrasive cleaners, steel wool, or harsh chemicals.
5.2 Cleaning the Exterior
Wipe exterior surfaces with a soft cloth and mild detergent. For stainless steel surfaces, wipe with the grain to prevent scratching.
5.3 Condenser Coil Cleaning
The condenser coil, located at the bottom of the unit, should be cleaned regularly (monthly or quarterly depending on environment) to maintain efficiency. A dirty condenser coil can lead to increased energy consumption and reduced cooling performance.
- Unplug the freezer.
- Remove the front grille panel to access the condenser coil.
- Use a stiff brush or vacuum cleaner with a brush attachment to remove dust and debris from the coil fins.
- Replace the front grille panel.
- Plug the freezer back in.
5.4 Door Gaskets
Inspect door gaskets regularly for cracks or tears. Clean them with warm, soapy water. Ensure they form a tight seal when the doors are closed to prevent cold air loss.
5.5 Automatic Defrost
This freezer features an automatic defrost system, eliminating the need for manual defrosting. During the defrost cycle, the internal temperature may temporarily rise slightly. This is normal operation.
6. Troubleshooting
Before contacting service, review the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Freezer not cooling |
|
|
| Excessive noise |
|
|
| Water on floor |
|
|
If the problem persists after attempting these solutions, contact qualified service personnel.
7. Specifications
| Feature | Detail |
|---|---|
| Model | MCF8703 |
| Brand | Atosa |
| Capacity | 47.1 Cubic Feet |
| Dimensions (W x D x H) | 54.41 x 31.5 x 83.16 inches (138.2 x 80 x 211.3 cm) |
| Item Weight | 462 pounds (209.5 kg) |
| Voltage | 115 Volts |
| Defrost System | Automatic |
| Number of Doors | 2, Glass |
| Door Hinges | Reversible |
| Shelves | 8, Adjustable (155 lbs capacity per shelf) |
| Compressor | Heavy duty Embraco, Bottom Mount |
| Fan Motor | EBM |
| Temperature Control | Dixell Digital |
| Special Features | LED interior lighting, Self-closing and stay-open doors, Recessed door handle, Standard safety door lock, Magnetic door gaskets, Pre-installed casters. |

Figure 6: Dimensional drawing of the Atosa MCF8703 freezer.

Figure 7: Energy label for the Atosa MCF8703 freezer. For more details, visit the EPREL database.
8. Warranty Information
The Atosa MCF8703 freezer comes with an industry-leading warranty:
- 2-Year Parts and Labor Warranty: Covers defects in materials and workmanship for two years from the date of purchase.
- 5-Year Compressor Warranty: Covers the compressor for five years from the date of purchase.
Please retain your proof of purchase for warranty claims. The warranty is subject to terms and conditions, including proper installation, operation, and maintenance as outlined in this manual. Unauthorized repairs or modifications may void the warranty.
9. Customer Support
For technical assistance, parts, or warranty inquiries, please contact your authorized Atosa dealer or customer service. Have your model number (MCF8703) and serial number ready when contacting support.