Trane GRL01347T

Trane Fan OEM Grille User Manual

Model: GRL01347 / GRL-1347 (GRL01347T)

Introduction

This manual provides essential information for the proper installation, operation, and maintenance of your Trane Fan OEM Grille, model GRL01347 / GRL-1347. Please read this manual thoroughly before installation and keep it for future reference.

The Trane Fan OEM Grille is an original equipment manufacturer (OEM) component designed for specific Trane HVAC units. It serves as a protective cover for the fan, ensuring safety and optimal airflow.

Safety Information

WARNING:

  • Always disconnect power to the HVAC unit before installing, servicing, or cleaning the fan grille. Failure to do so can result in electric shock or serious injury.
  • Installation should be performed by a qualified HVAC technician.
  • Wear appropriate personal protective equipment (PPE) during installation and maintenance.
  • Ensure the grille is securely fastened to prevent dislodgement during fan operation.

CAUTION:

  • Do not bend or deform the grille during handling or installation, as this may affect its structural integrity and airflow performance.
  • Use only the specified mounting hardware.

Product Overview

Trane Fan OEM Grille

Figure 1: The Trane Fan OEM Grille, showing its circular wire mesh design and central mounting hub.

Trane OEM Component Stamp

Figure 2: An illustration indicating the product is an Original Equipment Manufacturer (OEM) component from Trane.

The Trane Fan OEM Grille (Model GRL01347 / GRL-1347) is a critical component for HVAC systems, designed to protect the fan blades and prevent debris from entering the unit while allowing efficient airflow. This grille is an authentic Trane OEM part, ensuring compatibility and performance with specified Trane units.

Key features include:

  • Durable construction for long-lasting performance.
  • Designed to meet Trane's original specifications for fit and function.
  • Optimal airflow design to maintain system efficiency.

Specifications

Attribute Detail
Model Number GRL01347 / GRL-1347 (GRL01347T)
Brand Trane
Description Fan Grille, 25.51 Mounting Diameter
Item Weight 1 Pound
Color Black
Installation Type Bolt-On

Compatible Trane Units

This fan grille is compatible with a wide range of Trane HVAC units. Below is a partial list of commonly found compatible models. For a comprehensive list or to verify compatibility with your specific unit, please consult your unit's documentation or a qualified technician.

  • 2TTB3030A1000BA, 2TTB3030A1000CA, 2TTB3030A1000NA, 2TTB3030A1S00AA, 2TTB3030A1SE0AA
  • 2TTB3036A1000BA, 2TTB3036A1000CA, 2TTB3036A1000NA, 2TTB3036A1S00AA, 2TTB3036A1SE0AA
  • 2TWB3030A1000BA, 2TWB3030A1000CA
  • 2TTR0060A1000AA, 2TTR1060A1000AA, 2TTR2042A1000AA, 2TTR2042B1000AA, 2TTR2048A1000AA, 2TTR2060A1000AA
  • 2TTR3030A1000AA, 2TTR3036A1000AA, 2TTR4018A1000AA, 2TTR4024A1000AA, 2TTR4030A1000AA, 2TTR4036A1000AA
  • 2TWR1036H1000AA, 2TWR1036H1000AB, 2TWR1042A1000AA, 2TWR1042A1000AB, 2TWR1048A1000AA, 2TWR1048A1000AB
  • 4TTR2018A1000AA, 4TTR2024A1000AA, 4TTR2030A1000AA, 4TTR2030A1000AB, 4TTR2036A1000AA, 4TTR2036A1000AB
  • 4TWR2018A1000AA, 4TWR2018A1000AB, 4TWR2024A1000AA, 4TWR2024A1000AB, 4TWR2030A1000AA, 4TWR2030A1000AB

This grille is also a compatible replacement for GRL1347, GRL01347, GRL-1347, GRL01350, GRL-1350, GRL1350, GRL1368, GRL-1368, GRL01368, and others.

Setup and Installation

This section outlines the general steps for installing the Trane Fan OEM Grille. Always refer to your specific HVAC unit's service manual for detailed instructions and safety precautions.

  1. Preparation:
    • Ensure the HVAC unit is completely powered off and locked out.
    • Gather necessary tools, which may include a screwdriver, wrench, and appropriate PPE (gloves, safety glasses).
    • Inspect the new grille for any shipping damage.
  2. Removal of Old Grille (if applicable):
    • Carefully remove any fasteners securing the old fan grille.
    • Gently lift and remove the old grille, taking care not to damage the fan blades or surrounding components.
    • Clean the mounting area to ensure a proper fit for the new grille.
  3. Installation of New Grille:
    • Align the new Trane Fan OEM Grille with the mounting holes on the HVAC unit. The grille is designed for a 25.51-inch mounting diameter.
    • Insert the appropriate fasteners (bolts, screws) through the grille's mounting points and into the unit's frame.
    • Tighten all fasteners securely. Do not overtighten, as this can strip threads or damage the grille.
    • Ensure the grille is flush against the unit and does not wobble or have excessive play.
  4. Post-Installation Check:
    • Visually inspect the installed grille to confirm it is properly seated and all fasteners are tight.
    • Verify that there is no interference with the fan blades or other moving parts.
    • Restore power to the HVAC unit and perform a functional test to ensure proper operation.

Operating Instructions

The Trane Fan OEM Grille is a passive component designed to protect the fan. It does not require active operation. Its function is to remain securely in place, allowing the HVAC unit's fan to operate safely and efficiently.

Ensure that the grille is free from obstructions such as leaves, dirt, or other debris that could impede airflow or damage the fan. Regular visual inspection is recommended.

Maintenance

Regular maintenance of the fan grille helps ensure optimal performance and longevity of your HVAC unit.

  1. Cleaning:
    • Periodically inspect the grille for accumulation of dirt, leaves, or other debris.
    • If cleaning is required, ensure the HVAC unit is powered off.
    • Use a soft brush, cloth, or vacuum cleaner to remove debris. For stubborn dirt, a mild detergent solution and water can be used, followed by thorough rinsing and drying.
    • Do not use abrasive cleaners or solvents that could damage the grille's finish.
  2. Inspection:
    • Regularly check the grille for any signs of damage, such as bends, cracks, or loose welds.
    • Verify that all mounting fasteners are secure. Tighten any loose fasteners.
    • Ensure the grille is not corroding, especially in humid or coastal environments.

If the grille is significantly damaged or corroded, it should be replaced to maintain safety and system efficiency.

Troubleshooting

The Trane Fan OEM Grille is a simple, passive component. Most issues related to the grille are physical in nature.

Problem Possible Cause Solution
Grille is loose or rattling Loose mounting fasteners. Tighten all mounting fasteners.
Grille is bent or damaged Physical impact or improper handling. Replace the grille with a new OEM part.
Reduced airflow from unit Grille obstructed by debris. Clean the grille thoroughly.
Fan blades hitting grille Improper installation; bent grille; fan motor shifted. Ensure grille is properly seated and secured. Inspect fan motor mounting. If grille is bent, replace it. Consult a qualified technician.

For issues not listed here or if problems persist, contact a qualified HVAC technician.

Warranty and Support

As an OEM component, the Trane Fan OEM Grille is typically covered under the warranty of the HVAC unit it is installed in, or by a limited warranty from Trane for replacement parts. Specific warranty terms can vary.

For warranty claims or technical support regarding this Trane OEM part, please contact your authorized Trane dealer or the Trane customer service department. You may need to provide your HVAC unit's model and serial number, as well as proof of purchase for the grille.

Trane Customer Support: Refer to the official Trane website or your HVAC unit's documentation for the most current contact information.

Online Resources: For additional information and resources, visit the official Trane website: www.trane.com

Related Documents - GRL01347T

Preview Trane Comprehensive Chilled-Water System Design Catalog
Trane's comprehensive catalog for designing advanced chilled-water systems. This guide details system components, state-of-the-art design principles, configurations, and selection criteria for chillers, cooling towers, pumps, and control valves. It focuses on achieving efficiency, reliability, and cost-effectiveness in commercial and industrial HVAC applications, including insights on Tracer Chiller Plant Control and Trane Design Assist.
Preview Trane Precedent™ High Efficiency Packaged Rooftop Heat Pumps: Product Catalog
Discover the Trane Precedent™ series of high-efficiency packaged rooftop heat pumps, designed for exceptional reliability and advanced comfort control. This catalog details features, specifications, and applications for units ranging from 12.5 to 25 tons, highlighting Trane's commitment to quality and performance in commercial HVAC solutions.
Preview Trane 2025 Product Handbook: Residential & Light Commercial HVAC Systems
Discover the Trane 2025 Product Handbook, a comprehensive guide to residential and light commercial HVAC systems. Features include air conditioners, furnaces, heat pumps, air handlers, coils, thermostats, and IAQ products, with specifications for R-410A and low GWP refrigerants.
Preview Trane Rotary Spring Return Actuators 62 lb-in Series Installation Instructions
Comprehensive installation instructions for Trane Rotary Spring Return Actuators, 62 lb-in Series. Covers safety warnings, parts list, required tools, mounting positions, installation steps, manual override procedures, wiring diagrams, and dimensional specifications.
Preview Trane AFDR Retrofit Installation Instructions for RTHD Chillers
Comprehensive installation guide for Trane AFDR Retrofit Air-cooled Adaptive Frequency Drive™ for RTHD Chillers. Covers safety, environmental conditions, model details, and step-by-step installation procedures for qualified personnel.
Preview Trane Mitsubishi Electric Split-Type Air Conditioner Installation Manual
This installation manual provides detailed instructions and safety guidelines for Trane and Mitsubishi Electric split-type air conditioners, covering models NTXWST, NTYWST, NTXSST, NTYSST, NTXSSH series for professional installation.