Einhell GC-WW 6538

Einhell GC-WW 6538 Domestic Water Unit

Instruction Manual

Model: GC-WW 6538 | Brand: Einhell

1. Introduction

This manual provides essential information for the safe and efficient operation of your Einhell GC-WW 6538 Domestic Water Unit. Please read these instructions carefully before initial use and keep them for future reference. The GC-WW 6538 is designed for conveying clear water from various sources such as reservoirs, fountains, and shafts, suitable for irrigation systems, washing equipment, and toilet flushes. It features a robust 650-watt motor, a 20-liter pressure boiler, an integrated pressure switch, and a pressure gauge.

2. Safety Instructions

Always observe general safety regulations when operating electrical equipment. Ensure the unit is placed on a stable, level surface. Do not operate the pump with flammable or corrosive liquids. Disconnect the power supply before performing any maintenance or cleaning. Protect the unit from frost. Use only original spare parts and accessories.

3. Product Features

4. Setup

Proper setup is crucial for the optimal performance and longevity of your domestic water unit.

  1. Unpacking: Carefully remove all components from the packaging. Ensure all parts are present and undamaged.
  2. Placement: Position the unit on a firm, level surface, protected from weather and frost. Ensure adequate ventilation.
  3. Connecting the Suction Hose: Attach the included 7-meter suction hose to the suction inlet of the pump. Ensure a tight, airtight connection to prevent air ingress, which can impair pump performance.
Einhell GC-WW 6538 suction hose

Image: The included 7-meter suction hose with connectors, ready for attachment to the pump unit.

  1. Connecting the Pressure Line: Connect the pressure line (not included) to the pressure outlet of the pump. The unit features robust 33.3 mm (R1 AG) connections.
Einhell GC-WW 6538 connection point

Image: Close-up of the pump's connection point, showing the threaded inlet for secure hose attachment.

  1. Filling with Water: Before starting, fill the pump housing completely with water through the water filling screw. This is essential for priming the pump.
  2. Electrical Connection: Connect the unit to a properly grounded power outlet (230 Volts AC).
Einhell GC-WW 6538 installation diagram

Image: Diagram illustrating a typical installation setup for the domestic water unit, showing suction from a well and distribution to multiple taps, with a maximum suction height of 8m and maximum delivery height of 36m.

5. Operating Instructions

The Einhell GC-WW 6538 is designed for automatic operation.

  1. Initial Start-up: After filling the pump housing with water and connecting all hoses, plug in the unit. The pump will start automatically to build pressure in the 20-liter container.
  2. Automatic Operation: The integrated pressure switch monitors the system pressure. When water is drawn (e.g., by opening a tap), the pressure in the container drops, and the pump automatically switches on to replenish the pressure. Once the maximum pressure (3.6 bar) is reached, the pump switches off.
Einhell GC-WW 6538 pressure switch and gauge

Image: Close-up view of the integrated pressure switch and pressure gauge on the Einhell domestic water unit.

  1. Monitoring Pressure: The built-in pressure gauge allows you to monitor the system pressure at a glance.
Einhell GC-WW 6538 pressure gauge close-up

Image: Detailed view of the pressure gauge, indicating pressure in PSI and Bar, allowing for easy monitoring of the system's operational status.

Einhell GC-WW 6538 full unit view

Image: The complete Einhell GC-WW 6538 Domestic Water Unit, showcasing its red 20-liter pressure tank, pump, and integrated controls.

6. Maintenance

Regular maintenance ensures the longevity and reliable operation of your domestic water unit.

Einhell GC-WW 6538 water drain plug icon

Image: Icon indicating the water drain plug, essential for emptying the unit.

7. Troubleshooting

This section addresses common issues you might encounter with your domestic water unit.

ProblemPossible CauseSolution
Pump does not startNo power supply; Motor protection triggered; Air in pump.Check power connection; Allow motor to cool; Prime pump by filling with water.
Low pressure or no water deliverySuction line not airtight; Suction height too high; Filter clogged; Water source empty.Check all suction connections for leaks; Reduce suction height; Clean filter; Ensure adequate water supply.
Pump runs continuouslyLeak in pressure line; Pressure switch faulty.Inspect pressure lines for leaks; Contact customer support for pressure switch inspection.

8. Specifications

Technical data for the Einhell GC-WW 6538 Domestic Water Unit.

FeatureValue
Model Number4173193
Power Input650 Watts
Voltage230 Volts AC
Maximum Flow Rate3800 Liters Per Hour
Maximum Pressure3.6 Bar
Maximum Delivery Height36 meters
Maximum Suction Height8 meters
Container Volume20 Liters
Connections33.3 mm (R1 AG)
Item Weight10.5 Kilograms (approx. 23.1 pounds)
Product Dimensions19.69 x 10.63 x 19.49 inches
Einhell GC-WW 6538 performance curve

Image: Performance curve graph showing the relationship between delivery height (H) and flow rate (Q) for the Einhell GC-WW 6538, with maximums of 36m and 3800 l/h respectively.

Einhell GC-WW 6538 dimensions and connections diagram

Image: Diagram illustrating the key dimensions and connection points (33.3 mm R1 AG) of the Einhell GC-WW 6538 unit, including the 20-liter tank.

9. Warranty and Support

Einhell products are manufactured with quality and reliability in mind. For specific warranty information, please refer to the warranty card included with your product or visit the official Einhell website. In case of technical issues or questions not covered in this manual, please contact Einhell customer support. Have your model number (GC-WW 6538) and serial number ready when contacting support.

For further assistance, you may visit the official Einhell website: www.einhell.com

Related Documents - GC-WW 6538

Preview Einhell GC-AW 6333 Hauswasserautomat Bedienungsanleitung
Bedienungsanleitung für die Einhell GC-AW 6333 Hauswasserautomat. Enthält Informationen zur Installation, Bedienung, Wartung und Sicherheit des automatischen Hauswasserwerks.
Preview Einhell GC-CL 18 Li E Kit Cordless Leaf Blower: User Manual & Instructions
Instructions for use and overview of the Einhell GC-CL 18 Li E Kit Cordless Leaf Blower. Learn about product features, package contents, safety guidelines, device operation, charging, maintenance, troubleshooting, and specifications for this 18V Power X-Change system tool.
Preview Einhell GC-SC 18/28 Li Akku-Vertikutierer und Rasenlüfter Bedienungsanleitung
Die offizielle Bedienungsanleitung für den Einhell GC-SC 18/28 Li Akku-Vertikutierer und Rasenlüfter. Enthält Sicherheitshinweise, Bedienung, Wartung und Fehlerbehebung für Ihr Gartengerät.
Preview Einhell GC-ET 4530 Elektro-Rasentrimmer - Bedienungsanleitung
Umfassende Bedienungsanleitung für den Einhell GC-ET 4530 Elektro-Rasentrimmer. Enthält Sicherheitshinweise, Montage-, Betriebs-, Wartungs- und Fehlerbehebungsinformationen.
Preview Einhell GC-SP 2275 Klarwasserpumpe – Bedienungsanleitung
Originalbetriebsanleitung für die Einhell GC-SP 2275 Klarwasserpumpe. Enthält Sicherheitshinweise, Installations-, Betriebs-, Wartungs- und Fehlerbehebungsanleitungen. Besuchen Sie www.Einhell-Service.com für weitere Informationen.
Preview Einhell GC-HM 300 / GC-HM 400 Hand-Rasenmäher Bedienungsanleitung
Offizielle Bedienungsanleitung für den Einhell GC-HM 300 und GC-HM 400 Hand-Rasenmäher. Enthält Informationen zu Sicherheit, Montage, Bedienung, Wartung und Fehlerbehebung.