1. Introduction
The Diversitech T2404 is a 40VA control transformer designed to provide reliable power for low-voltage control circuits. It features multiple primary voltage taps (120V, 208V, 240V AC) and a single 24V AC secondary output, making it suitable for various applications, commonly found in HVAC systems. This manual outlines the proper procedures for installation, operation, and maintenance to ensure safe and efficient performance of the unit.

Image of the Diversitech T2404 control transformer, showing its compact design and terminal connections.
2. Safety Information
Read and understand all instructions before installing or operating this transformer. Failure to follow these instructions may result in electric shock, fire, or property damage.
- Disconnect Power: Always disconnect power at the main service panel before installing, servicing, or removing the transformer.
- Qualified Personnel: Installation and servicing should only be performed by qualified, licensed electricians or HVAC technicians.
- Local Codes: All wiring must comply with national and local electrical codes.
- Proper Grounding: Ensure the transformer is properly grounded according to local electrical codes.
- Voltage Verification: Verify input and output voltages with a multimeter before connecting any loads.
- Overload Protection: Do not exceed the transformer's 40VA rating. Overloading can cause overheating and damage.
3. Technical Specifications
| Specification | Value |
|---|---|
| Model | T2404 |
| VA Rating | 40VA |
| Primary Voltage | 120V AC / 208V AC / 240V AC |
| Secondary Voltage | 24V AC |
| Frequency | 50/60 Hz |
| Manufacturer | Diversitech |
| ASIN | B01N44GFF7 |
4. Installation Instructions
Follow these steps for proper installation. Always ensure power is disconnected before beginning any work.
- Power Disconnection: Turn off the main power supply to the circuit where the transformer will be installed. Verify with a voltage tester that power is off.
- Mounting: Mount the transformer securely in a suitable enclosure or location, ensuring adequate ventilation and protection from moisture and physical damage.
- Primary Wiring: Connect the appropriate primary voltage wires (120V, 208V, or 240V AC) to the designated primary terminals on the transformer. Refer to the transformer's labeling for specific terminal identification. Ensure connections are tight and secure.
- Secondary Wiring: Connect the low-voltage control circuit wires to the 24V AC secondary terminals.
- Grounding: Connect the transformer's ground terminal to a proper earth ground according to local electrical codes.
- Verification: Double-check all wiring connections for correctness and tightness. Ensure no bare wires are exposed.
- Restore Power: Once all connections are verified and secure, restore power to the circuit.
Note: If you are unsure about any part of the installation process, consult a qualified electrician or HVAC technician.
5. Operation
The Diversitech T2404 transformer operates by converting a higher primary voltage (120V, 208V, or 240V AC) to a lower, constant 24V AC secondary voltage. Once properly installed and powered, it will continuously supply 24V AC to the connected low-voltage control circuit, provided the total load does not exceed its 40VA rating. The transformer is designed for continuous duty within its specified parameters.
6. Maintenance
The T2404 transformer is designed for reliable, long-term operation with minimal maintenance. However, periodic checks can help ensure optimal performance and longevity.
- Visual Inspection: Periodically inspect the transformer for any signs of physical damage, corrosion, or loose connections.
- Cleanliness: Keep the transformer free from dust, dirt, and debris, which can impede heat dissipation.
- Ventilation: Ensure that the installation area maintains adequate ventilation to prevent overheating.
- Connection Check: Occasionally check terminal connections to ensure they remain tight and secure.
7. Troubleshooting
If the transformer is not functioning as expected, refer to the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| No 24V AC output |
|
|
| Low 24V AC output |
|
|
| Transformer overheating |
|
|
If troubleshooting steps do not resolve the issue, contact a qualified technician.
8. Warranty and Support
For specific warranty information regarding the Diversitech T2404 transformer, please refer to the official Diversitech website or contact their customer support directly. Warranty terms typically cover manufacturing defects for a specified period from the date of purchase.
For technical assistance, product inquiries, or to locate authorized service providers, please visit the Diversitech Store on Amazon or the manufacturer's official website.