Field Controls UV 16

Field Controls UV-16/120 UV-Aire In Duct Air Purifier

User Manual

1. Introduction and Product Overview

The Field Controls UV-16/120 UV-Aire In Duct Air Purifier is designed to improve indoor air quality by utilizing ultraviolet (UV-C) light technology. This device is installed directly into your HVAC system's ductwork, where it neutralizes airborne contaminants such as bacteria, viruses, mold spores, and allergens as air passes through. This manual provides essential information for the safe and effective installation, operation, and maintenance of your UV-Aire system.

Field Controls UV-16/120 UV-Aire In Duct Air Purifier unit with a glowing UV lamp extending from the side.

This image displays the Field Controls UV-16/120 UV-Aire In Duct Air Purifier, a compact white unit designed for installation within HVAC ductwork. A blue glowing UV lamp is visible extending from the right side of the main housing, indicating its air purification function.

2. Safety Information

Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Package Contents

Verify that all components are present and undamaged before beginning installation. If any items are missing or damaged, contact your supplier immediately.

4. Setup and Installation

The UV-16/120 UV-Aire unit is designed for installation within the return or supply air duct of your HVAC system. Proper placement is crucial for effective air purification.

  1. Power Disconnection: Turn off all power to the HVAC system at the main electrical panel or circuit breaker. Verify power is off using a voltage tester.
  2. Select Installation Location: Choose a location in the ductwork that allows for sufficient airflow around the UV lamp and provides easy access for future maintenance (e.g., bulb replacement). Ensure there is at least 16 inches of clear space for the lamp.
  3. Cut Opening: Using the provided template (if applicable) or the unit's dimensions, carefully cut an opening in the ductwork for the main housing of the UV-Aire unit. Ensure the opening is clean and free of sharp edges.
  4. Mount the Unit: Insert the UV-Aire unit into the cut opening. Secure the unit to the ductwork using the provided mounting screws. Ensure a tight seal to prevent air leakage.
  5. Electrical Connection: Connect the unit's power cord to a dedicated 120 Volt power source, typically wired into the HVAC system's control circuit so it operates when the fan is running. Follow all local electrical codes. The unit features a safety disconnect for added protection.
  6. Install UV Lamp: If the lamp is not pre-installed, carefully insert the UV-C lamp into its receptacle on the unit. Ensure it is securely seated. Avoid touching the glass portion of the lamp with bare hands.
  7. Restore Power: Once installation is complete and all connections are secure, restore power to the HVAC system.

5. Operating Instructions

The Field Controls UV-16/120 UV-Aire In Duct Air Purifier is designed for continuous operation when your HVAC system's fan is running. It does not require daily user interaction.

6. Maintenance

Regular maintenance ensures the continued effectiveness and longevity of your UV-Aire system.

7. Troubleshooting

If your UV-Aire system is not functioning as expected, refer to the following common issues and solutions:

ProblemPossible CauseSolution
UV lamp is not litNo power to the unitCheck circuit breaker. Ensure HVAC fan is running if wired to fan circuit.
UV lamp is not litLamp has reached end of lifeReplace UV lamp (refer to Maintenance section).
UV lamp is not litFaulty ballastContact a qualified technician for inspection and replacement of the ballast. (Note: Some users have reported ballast failure after extended use.)
Reduced air purification effectivenessLamp is old or dirtyReplace or clean the UV lamp.
Unit making unusual noiseLoose mounting or internal component issueEnsure unit is securely mounted. If noise persists, contact a qualified technician.

If the problem persists after attempting these solutions, contact Field Controls customer support or a qualified HVAC professional.

8. Specifications

Key technical specifications for the Field Controls UV-16/120 UV-Aire In Duct Air Purifier:

9. Warranty Information

Specific warranty terms for the Field Controls UV-16/120 UV-Aire In Duct Air Purifier are typically provided at the time of purchase or can be obtained directly from Field Controls or your authorized dealer. It is recommended to retain your proof of purchase for warranty claims.

Extended protection plans may be available from third-party providers at the point of sale. These plans are separate from the manufacturer's warranty.

10. Support

For technical assistance, replacement parts, or further inquiries regarding your Field Controls UV-16/120 UV-Aire In Duct Air Purifier, please contact:

When contacting support, please have your product model number (UV 16) and date of purchase readily available.

Related Documents - UV 16

Preview UV-AIRE™ UV-500C Air Purifying System: User Manual and Specifications
This document provides comprehensive instructions for the UV-AIRE™ UV-500C Air Purifying System by Field Controls. It includes setup procedures, operation guidelines, maintenance schedules, replacement instructions for lamps and filters, and warranty information. Learn how to effectively use the system to improve indoor air quality by removing airborne contaminants like mold, bacteria, viruses, allergens, dust, pollen, and VOCs.
Preview Field Controls Duo-2000 Photo-Catalytic Air Purifier Installation Manual
Comprehensive installation, maintenance, and troubleshooting guide for the Field Controls Duo-2000 Photo-Catalytic Air Purifier, designed to sterilize and purify air in residential HVAC systems using UVC light and photocatalytic technology.
Preview Trio Plus Air Purifier User Manual | Field Controls
Comprehensive user manual for the Field Controls Trio Plus air purifier, covering safety, operation, maintenance, filter replacement, troubleshooting, and specifications.
Preview Field Controls Trio Plus Air Purifier User Manual
Comprehensive user manual for the Field Controls Trio Plus Air Purifier, covering setup, operation, maintenance, safety guidelines, and troubleshooting for optimal indoor air quality.
Preview Field Controls S2000 & S2020 Power Humidifier: Installation & Owner Manual
Comprehensive installation instructions and owner's manual for Field Controls S2000 (120VAC) and S2020 (240VAC) electronic steam power humidifiers. Learn how to install, operate, and maintain your unit for optimal performance in forced air systems.
Preview Field Controls CAS-34U Combustion Air System Installation Guide
Installation and operation guide for the Field Controls CAS-34U Combustion Air System. Learn about specifications, sizing, setup, wiring, maintenance, and troubleshooting for oil and gas appliances.