Introduction
This user manual provides essential information for the safe and efficient installation, operation, and maintenance of your Legrand Mosaic 077014 Pull-Cord Switch. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety. Keep this manual for future reference.
Safety Information
WARNING: Electrical shock hazard. Installation and servicing of this product must be performed by a qualified electrician in accordance with all national and local electrical codes and regulations.
- Always disconnect power at the circuit breaker or fuse box before installing or servicing the switch.
- Verify that the power is off before proceeding.
- Do not install this product with wet hands or while standing on wet surfaces.
- Ensure all wire connections are secure and properly insulated.
- This product is designed for indoor use only.
- Do not exceed the specified voltage and current ratings.
Product Overview
The Legrand Mosaic 077014 is a 2-way, 2-module pull-cord switch designed for various electrical applications. It features quick connect automatic terminals for tool-free installation, simplifying the wiring process. This switch is part of the Legrand Mosaic™ Program, known for its modular and versatile electrical components.

Figure 1: Front view of the Legrand Mosaic 077014 Pull-Cord Switch. This image shows the white 2-module unit with its integrated pull cord mechanism.
Key Features:
- Model: 077014
- Type: Pull-Cord Switch
- Functionality: 2-Way (allows control from two locations)
- Modules: 2 Modules (standard Legrand Mosaic size)
- Voltage Rating: 10 - 250 Volts AC
- Terminals: Quick connect automatic terminals (tool-free)
- Color: White
Installation
IMPORTANT: Installation should only be carried out by a qualified electrician. Ensure all power is disconnected before beginning installation.
- Power Disconnection: Locate the circuit breaker or fuse controlling the circuit where the switch will be installed. Turn off the power completely. Verify with a voltage tester that the power is off.
- Preparation: Remove the existing switch or prepare the mounting box for the new switch.
- Wiring:
- Identify the live (phase) wire, neutral wire, and load wire(s) according to local wiring codes.
- The Legrand Mosaic 077014 features quick connect automatic terminals. Strip approximately 10-12mm of insulation from the ends of the wires.
- Insert the stripped wires firmly into the appropriate terminals. Ensure a secure connection. For a 2-way switch, typically three terminals are used: common, L1, and L2. Refer to the wiring diagram provided with the product packaging for specific connections.
- Mounting: Secure the switch module into the Legrand Mosaic support frame (sold separately) and then into the wall box.
- Cover Plate: Attach the appropriate cover plate (sold separately) to complete the installation.
- Power Restoration: Once installation is complete and all connections are secure, restore power at the circuit breaker.
- Testing: Test the switch functionality to ensure it operates correctly.
For detailed wiring diagrams and specific installation scenarios, always consult the documentation provided with the product packaging or contact Legrand technical support.
Operation
The Legrand Mosaic 077014 is a simple pull-cord switch. To operate:
- To Turn ON/OFF: Gently pull the cord downwards. Each pull will toggle the connected electrical circuit between ON and OFF states.
- 2-Way Functionality: As a 2-way switch, it can be used in conjunction with another 2-way switch to control a single light or appliance from two different locations. Pulling the cord on either switch will change the state of the circuit.
Ensure the cord is not excessively pulled or subjected to undue force, as this may damage the internal mechanism.
Maintenance
The Legrand Mosaic 077014 Pull-Cord Switch requires minimal maintenance.
- Cleaning: To clean the surface of the switch, wipe it with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.
- Internal Components: There are no user-serviceable parts inside the switch. Do not attempt to open or repair the unit.
- Cord Inspection: Periodically inspect the pull cord for any signs of fraying or damage. If the cord is damaged, contact a qualified electrician for replacement or repair of the switch.
Always ensure power is disconnected before performing any cleaning or inspection that involves touching the switch directly.
Troubleshooting
If you experience issues with your Legrand Mosaic 077014 Pull-Cord Switch, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Switch does not operate (no power to load). |
|
|
| Switch operates intermittently. |
|
|
| Pull cord is damaged or frayed. |
|
|
For problems not listed here or if solutions do not resolve the issue, contact Legrand customer support or a qualified electrician.
Specifications
| Brand: | Legrand |
| Model: | 077014 |
| Manufacturer Reference: | 0307523 |
| Product Type: | Pull-Cord Switch |
| Functionality: | 2-Way |
| Modules: | 2 Modules |
| Voltage Rating: | 10 - 250 Volts AC |
| Terminals: | Quick connect automatic (tool-free) |
| Color: | White |
Warranty and Support
For information regarding product warranty, please refer to the warranty card included with your purchase or visit the official Legrand website. For technical support, replacement parts, or further assistance, please contact Legrand customer service through their official channels. Do not attempt to repair the product yourself, as this may void the warranty and pose safety risks.