Introduction
This manual provides essential instructions for the safe operation, maintenance, and troubleshooting of your Pulsar PG5250B Dual Fuel Portable Generator. This generator is designed to provide reliable power using either gasoline or liquid propane gas (LPG), offering versatility for various power needs. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
Important Safety Information
Failure to follow these instructions can result in serious injury or death.
- Carbon Monoxide Hazard: Generators produce carbon monoxide, an odorless, colorless, poisonous gas. Operate generators outdoors only, far away from windows, doors, and vents. Never operate in an enclosed space.
- Electrical Shock Hazard: Never operate the generator in wet conditions. Ensure all electrical connections are dry and properly grounded. Do not connect the generator directly to your home's electrical system without a transfer switch installed by a qualified electrician.
- Fire Hazard: Gasoline and propane are highly flammable. Refuel only when the engine is off and cool. Store fuel in approved containers in a well-ventilated area, away from ignition sources. Do not smoke near the generator or fuel.
- Hot Surfaces: The generator engine and muffler become very hot during operation and remain hot for a period after shutdown. Avoid contact to prevent burns.
- Moving Parts: Keep hands, feet, hair, and clothing away from moving parts to prevent injury.
- Children and Pets: Keep children and pets away from the generator at all times.
Product Overview
The Pulsar PG5250B is a robust dual-fuel portable generator designed for versatility and power. It features a durable frame, convenient outlets, and the ability to switch between gasoline and propane operation.
Key Components and Controls

Figure 1: Front view of the Pulsar PG5250B generator, highlighting the control panel, engine, and frame. The control panel includes various outlets, a 3-in-1 digital meter, and the fuel selector switch.
- Control Panel: Centralized interface for operating the generator, including outlets, switches, and indicators.
- Fuel Selector Switch: Allows selection between gasoline and propane (LPG) fuel sources. Features "Switch & Go Technology" for seamless transitions.
- Outlets: Includes (2) 120V AC Outlets, (1) 30Amp RV Port, and (1) 120/240V Twist-Lock Outlet for diverse power needs.
- 3-in-1 Digital Meter: Displays essential operational data such as voltage, frequency, and hour meter.
- Low Oil Indicator/Shutdown: Protects the engine by automatically shutting down if oil levels are too low.
- 224cc 4-Stroke OHV Engine: Provides reliable power output.
- Durable Powder Coated Steel Frame: Protects internal components and provides a sturdy structure.
- Fold-Down Handle & Never-Flat Wheels: Facilitate easy transport and storage.
- LPG Connection: Dedicated port for connecting a propane tank.
Setup Instructions
Before operating your generator, follow these steps to ensure it is properly prepared for use.
1. Unpacking and Assembly
- Carefully remove the generator and all components from the packaging.
- Attach the wheels and support legs using the provided hardware.
- Install the fold-down handle.
2. Adding Engine Oil
- Place the generator on a level surface.
- Remove the oil fill cap/dipstick.
- Add the recommended engine oil (refer to specifications for type and capacity) until it reaches the upper mark on the dipstick. Do not overfill.
- Securely replace the oil fill cap/dipstick.
3. Fuel Connection
The PG5250B operates on either gasoline or propane (LPG).
For Gasoline Operation:
- Ensure the engine is off and cool before adding fuel.
- Use fresh, unleaded gasoline with an octane rating of 87 or higher.
- Fill the 4-gallon fuel tank, leaving a small space for expansion. Do not overfill.
- Securely replace the fuel cap.
For Propane (LPG) Operation:
- Connect the provided propane hose to the generator's LPG connection port and to a standard propane tank.
- Ensure all connections are tight to prevent leaks.
- Slowly open the valve on the propane tank.
Operating Instructions
Always operate the generator in a well-ventilated outdoor area, away from any structures.
Starting the Generator (Gasoline)
- Ensure the generator is on a level surface.
- Turn the fuel selector switch to the "Gasoline" position.
- Turn the engine switch to "ON".
- Move the choke lever to the "CHOKE" position (if engine is cold).
- Pull the recoil starter handle firmly and steadily until the engine starts.
- Once the engine starts, slowly move the choke lever to the "RUN" position.
Starting the Generator (Propane)
- Ensure the generator is on a level surface.
- Ensure the propane tank valve is fully open.
- Turn the fuel selector switch to the "LPG" position.
- Turn the engine switch to "ON".
- Move the choke lever to the "CHOKE" position (if engine is cold).
- Pull the recoil starter handle firmly and steadily until the engine starts. Propane may require a few more pulls than gasoline.
- Once the engine starts, slowly move the choke lever to the "RUN" position.
Switching Fuel Sources (Switch & Go Technology)
The PG5250B allows for seamless transitioning between gasoline and propane while the generator is running.
- To switch from Gasoline to LPG: While the generator is running on gasoline, slowly turn the fuel selector switch to the "LPG" position. The engine may briefly hesitate before smoothly transitioning to propane.
- To switch from LPG to Gasoline: While the generator is running on propane, slowly turn the fuel selector switch to the "Gasoline" position. Ensure there is gasoline in the tank. The engine will transition to gasoline operation.
Connecting Electrical Loads
- Allow the generator to run for a few minutes to stabilize after starting.
- Plug in your appliances or extension cords to the appropriate outlets.
- Do not overload the generator. Refer to the specifications for maximum wattage.
Shutting Down the Generator
- Disconnect all electrical loads from the generator.
- If running on gasoline, turn the fuel valve to the "OFF" position and allow the engine to run until it runs out of fuel. This helps prevent carburetor issues.
- If running on propane, close the valve on the propane tank. The engine will run until the remaining propane in the line is consumed.
- Turn the engine switch to "OFF".
Maintenance
Regular maintenance is crucial for the longevity and reliable operation of your generator. Always ensure the engine is off and cool before performing any maintenance.
Maintenance Schedule (General Guidelines)
- Before Each Use: Check engine oil level. Inspect for loose hardware or fuel leaks.
- Every 25 Hours or Annually: Change engine oil. Clean or replace air filter. Inspect spark plug.
- Every 100 Hours or Annually: Replace spark plug. Inspect fuel filter. Clean cooling fins.
Engine Oil Change
- Run the engine for a few minutes to warm the oil, then shut it off.
- Place a drain pan under the oil drain plug.
- Remove the oil drain plug and oil fill cap/dipstick to allow oil to drain completely.
- Replace the drain plug and refill with the recommended amount and type of new engine oil.
- Check the oil level with the dipstick and replace the oil fill cap.
Air Filter Maintenance
- Remove the air filter cover.
- Remove the foam filter element.
- Wash the foam element in warm, soapy water, rinse thoroughly, and allow to air dry completely.
- Lightly oil the foam element with engine oil and squeeze out excess.
- Reinstall the air filter and cover. Replace if damaged.
Storage
- For gasoline, add a fuel stabilizer or drain the fuel tank and carburetor completely to prevent gumming.
- Change the engine oil.
- Remove the spark plug and pour a small amount of engine oil into the cylinder. Pull the recoil starter a few times to distribute the oil, then reinstall the spark plug.
- Store the generator in a clean, dry, well-ventilated area.
Troubleshooting
This section addresses common issues you might encounter with your generator.
| Problem | Possible Cause | Solution |
|---|---|---|
| Engine will not start |
|
|
| Engine starts then stops |
|
|
| No power output |
|
|
| Engine runs rough |
|
|
Specifications
Detailed technical specifications for the Pulsar PG5250B Dual Fuel Portable Generator.
| Feature | Detail |
|---|---|
| Model | PG5250B |
| Engine Type | 224cc, 4-Stroke, OHV, Air Cooled |
| Fuel Type | Dual Fuel (Gasoline / LPG) |
| Gasoline Peak Wattage | 5,250W |
| Gasoline Rated Wattage | 4,250W |
| LPG Peak Wattage | 4,750W |
| LPG Rated Wattage | 3,850W |
| Fuel Tank Capacity | 4 Gallons |
| Run Time (Gasoline @ 1/2 load) | Up to 12 Hours |
| Voltage | 120V / 240V |
| Outlets | (2) 120V AC, (1) 30A RV, (1) 120/240V Twist-Lock, (1) 12V DC |
| Item Weight | 115 Pounds |
| Product Dimensions (L x W x H) | 24"L x 18.1"W x 19.9"H |
| Special Features | Switch & Go Technology, 3-in-1 Digital Meter, Low Oil Indicator, Low Oil Shutdown, Fold-Down Handle, Never-Flat Wheels |

Figure 2: Dimensions of the Pulsar PG5250B generator, showing length, width, and height measurements.
Warranty and Support
Warranty Information
The Pulsar PG5250B Dual Fuel Portable Generator comes with a 2-Year Limited Warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For full warranty terms and conditions, refer to the documentation included with your product or contact Pulsar customer support.
Customer Support
For technical assistance, parts, or warranty inquiries, please contact Pulsar Customer Support. Contact information can typically be found on the manufacturer's website or in the packaging materials. When contacting support, please have your model number (PG5250B) and serial number ready.