This manual provides essential information for the safe and effective use of your Beurer BM 35 Upper Arm Blood Pressure Monitor and Beurer FT 09/1 Clinical Thermometer. Please read these instructions carefully before first use and keep them for future reference.
1. Important Safety Information
- Consult your doctor before using the device if you have any medical conditions.
- Do not self-diagnose or self-medicate based on measurements. Always consult a healthcare professional.
- Keep devices out of reach of children.
- Use only the specified batteries. Do not mix old and new batteries or different types of batteries.
- Protect devices from moisture, extreme temperatures, direct sunlight, and strong impacts.
- Do not attempt to repair the devices yourself. Contact authorized service personnel.
2. Package Contents
Verify that all items are present and undamaged upon unpacking:
- Beurer BM 35 Upper Arm Blood Pressure Monitor
- Upper arm cuff
- Beurer FT 09/1 Clinical Thermometer
- Storage bag (for BM 35)
- Protective cap (for FT 09/1)
- Instruction manual
3. Device Overview
3.1 Beurer BM 35 Blood Pressure Monitor

This image shows the Beurer BM 35 upper arm blood pressure monitor, featuring its digital display, control buttons, and the attached arm cuff. The display indicates systolic, diastolic, and pulse readings, along with an irregular heart rhythm symbol and a risk indicator.

An infographic illustrating key features of the Beurer BM 35 blood pressure monitor, including detection of irregular heart rhythm, its status as a medical device, and a risk indicator for blood pressure values.
- Display: Shows systolic, diastolic, pulse, date, time, and user memory.
- START/STOP button: Powers the device on/off and starts/stops measurement.
- M (Memory) button: Accesses stored measurements.
- User selection buttons (+/-): Selects user memory.
- Cuff connection: Port for connecting the air tube from the cuff.
- Battery compartment: Located on the back.
3.2 Beurer FT 09/1 Clinical Thermometer

This image displays the Beurer FT 09/1 clinical thermometer, a white digital thermometer with a flexible tip and a clear display showing a temperature reading of 37.0°C.
- Display: Shows temperature readings.
- ON/OFF button: Powers the device on/off.
- Measurement tip: Flexible tip for comfortable measurement.
- Battery compartment: Located at the end of the thermometer.
4. Setup
4.1 Beurer BM 35 Blood Pressure Monitor
- Insert Batteries: Open the battery compartment on the back of the device. Insert 4 x 1.5V AA batteries, ensuring correct polarity (+/-). Close the compartment.
- Connect Cuff: Insert the air tube connector of the cuff into the port on the left side of the blood pressure monitor.
- Set Date and Time: After inserting batteries, the device will prompt you to set the date and time. Use the user selection buttons (+/-) to adjust values and the M button to confirm and move to the next setting.
4.2 Beurer FT 09/1 Clinical Thermometer
- Battery: The thermometer comes with a pre-installed battery. If replacement is needed, refer to the 'Maintenance' section.
5. Operating Instructions
5.1 Blood Pressure Measurement with BM 35
- Preparation: Rest for at least 5 minutes before measurement. Avoid eating, drinking, smoking, or exercising for 30 minutes prior. Sit upright with your feet flat on the floor and your arm resting comfortably on a table.
- Cuff Placement: Place the cuff on your bare upper arm, approximately 2-3 cm above the elbow joint. The air tube should run along the inside of your arm. Ensure the cuff is snug but not too tight.
- Start Measurement: Press the START/STOP button. The cuff will inflate automatically, and the measurement will begin. Remain still and do not talk during the measurement.
- Reading Results: Once the measurement is complete, the systolic pressure, diastolic pressure, and pulse rate will be displayed. The device also indicates irregular heart rhythm (if detected) and a color-coded risk indicator.
- Memory Function: The device automatically stores measurements for two users (60 memory spaces each). Press the M button to view stored readings. Use the user selection buttons (+/-) to switch between users.
- Power Off: The device will automatically switch off after approximately one minute of inactivity. You can also press the START/STOP button to turn it off manually.

A woman is shown seated at a table, correctly positioning the cuff of the Beurer BM 35 blood pressure monitor on her upper arm, demonstrating proper usage for measurement.

A detailed view of the Beurer BM 35 blood pressure monitor's display, highlighting the large digits for systolic (128 mmHg) and diastolic (83 mmHg) pressure, pulse rate (69 beats/min), and the color-coded risk indicator.
5.2 Temperature Measurement with FT 09/1
- Turn On: Press the ON/OFF button. A short beep will sound, and the display will show the last measured temperature for approximately 2 seconds, followed by 'L°C' (or 'L°F') and a flashing '°C' (or '°F').
- Measurement: Place the measurement tip in the desired position (oral, axillary, or rectal).
- Reading Results: The temperature is measured continuously. A long beep will sound when the final temperature is reached (usually within 10-40 seconds, depending on the measurement site). The measured value will be displayed.
- Memory Function: The last measured temperature is automatically stored.
- Power Off: The thermometer will automatically switch off after approximately 10 minutes of inactivity. You can also press the ON/OFF button to turn it off manually.

A close-up of the Beurer FT 09/1 clinical thermometer's digital display, clearly showing a temperature reading of 37.0°C.

This image focuses on the flexible, waterproof tip of the Beurer FT 09/1 clinical thermometer, designed for comfortable and hygienic temperature measurement.
6. Maintenance and Care
6.1 Cleaning
- BM 35 Monitor: Clean the device and cuff carefully with a slightly damp cloth. Do not use abrasive cleaners or immerse the device in water.
- FT 09/1 Thermometer: The thermometer is waterproof and can be disinfected. Clean the measurement tip with a cotton swab moistened with alcohol or cold water. Do not boil the thermometer.
6.2 Storage
- Store both devices in a cool, dry place, away from direct sunlight and extreme temperatures.
- Keep the BM 35 in its storage bag when not in use.
- Keep the FT 09/1 in its protective cap.
6.3 Battery Replacement
- BM 35 Monitor: When the low battery indicator appears on the display, replace all four AA batteries with new ones.
- FT 09/1 Thermometer: If the display shows a battery symbol, the battery needs to be replaced. Refer to the specific instructions in the thermometer's manual for battery compartment access and replacement.
7. Troubleshooting
7.1 Beurer BM 35 Blood Pressure Monitor
| Problem | Possible Cause | Solution |
|---|---|---|
| Error message 'E1' | Cuff not correctly applied or air leakage. | Re-apply the cuff correctly and ensure the air tube is securely connected. |
| Error message 'E2' | Movement during measurement. | Remain still and silent during measurement. Repeat the measurement. |
| Low battery indicator | Batteries are low. | Replace all batteries with new 1.5V AA batteries. |
| No display | Batteries inserted incorrectly or completely drained. | Check battery polarity or replace batteries. |
7.2 Beurer FT 09/1 Clinical Thermometer
| Problem | Possible Cause | Solution |
|---|---|---|
| Display shows 'Err' | Measurement error or device malfunction. | Ensure proper contact during measurement. If error persists, contact customer support. |
| Display is blank | Battery is drained. | Replace the battery. |
8. Specifications
8.1 Beurer BM 35 Blood Pressure Monitor
- Measurement Method: Oscillometric, non-invasive blood pressure measurement on the upper arm.
- Measurement Range: Cuff pressure 0-300 mmHg, Systolic 50-250 mmHg, Diastolic 30-200 mmHg, Pulse 40-180 beats/minute.
- Accuracy: Pressure +/- 3 mmHg, Pulse +/- 5% of the displayed value.
- Memory: 2 x 60 memory spaces.
- Power Source: 4 x 1.5V AA batteries.
- Dimensions (L x W x H): Approximately 135 x 105 x 53 mm.
- Weight: Approximately 326 g (with cuff, without batteries).
8.2 Beurer FT 09/1 Clinical Thermometer
- Measurement Method: Contact-measurement technology.
- Measurement Range: 32.0 °C to 42.9 °C (89.6 °F to 109.2 °F).
- Accuracy: +/- 0.1 °C (between 35.5 °C and 42.0 °C).
- Display: In °C.
- Features: Waterproof, no mercury, without glass, can be disinfected, 1 memory space, automatic switch-off, acoustic signal when measurement is complete.
9. Warranty and Support
The Beurer BM 35 Blood Pressure Monitor and FT 09/1 Clinical Thermometer come with a 5-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
The warranty does not cover damage resulting from:
- Improper use or handling.
- Failure to follow the operating instructions.
- Repairs or modifications performed by unauthorized parties.
- Damage during transport.
- Normal wear and tear of accessories (e.g., cuff, batteries).
For warranty claims or technical support, please contact:
Beurer India Pvt. Ltd.523-524, JMD Megapolis, Sohna Road,
Sector- 48, Gurugram- 122018 India
Email: info@beurer.com