WASOTO HOM250CP

WASOTO HOM250CP 50-Amp 2-Pole Plug-On Circuit Breaker User Manual

Model: HOM250CP | Brand: WASOTO

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of your WASOTO HOM250CP 50-Amp 2-Pole Plug-On Circuit Breaker. Please read these instructions thoroughly before proceeding with any installation or operation to ensure proper function and safety.

2. Important Safety Information

WARNING: Electrical shock hazard. Improper installation or maintenance can result in serious injury or death. Always follow these safety guidelines:

  • Always disconnect power at the main service panel before working on or near electrical equipment.
  • Installation and servicing should only be performed by qualified, licensed electricians.
  • Ensure all local and national electrical codes are followed.
  • Do not use this circuit breaker if it appears damaged.
  • Verify the circuit breaker's ratings (voltage, amperage, interrupt capacity) match the application requirements.

3. Product Overview

The WASOTO HOM250CP is a 50-Amp, 2-pole plug-on circuit breaker designed for use in compatible electrical load centers. It provides overcurrent protection for electrical circuits, automatically tripping to interrupt the flow of electricity when a fault or overload condition occurs.

WASOTO HOM250CP 50-Amp 2-Pole Plug-On Circuit Breaker

Figure 1: A close-up view of the WASOTO HOM250CP 50-Amp 2-Pole Plug-On Circuit Breaker, showing its two levers, each marked '50', and the 'ON' and 'OFF' positions. The label indicates 'TYPE HOM', '10 kA', '120/240 V~', and 'LISTED C.B.'.

Key Features:

  • Current Rating: 50 Amps
  • Number of Poles: 2
  • Mounting Type: Plug-In Mount
  • Circuit Breaker Type: Standard (Magnetic Thermal)
  • Voltage Rating: 120/240 V~ (as indicated on the device)
  • Interrupting Capacity: 10 kA (as indicated on the device)

4. Installation Instructions

Before You Begin: Ensure the main power to the load center is OFF. Use appropriate personal protective equipment (PPE).

  1. De-energize the Panel: Locate the main service disconnect for your electrical panel and turn it to the OFF position. Verify power is off using a voltage tester.
  2. Remove Panel Cover: Carefully remove the cover of the electrical load center.
  3. Identify Slot: Select an appropriate slot in the load center for a 2-pole circuit breaker. Ensure it is compatible with 'TYPE HOM' breakers.
  4. Connect Wires: Connect the load wires (typically two hot wires) to the terminals on the circuit breaker. Ensure connections are tight and secure according to the torque specifications provided by the load center manufacturer.
  5. Install Breaker: Align the circuit breaker with the bus bar stabs in the load center. Firmly push the breaker onto the stabs until it is fully seated and clicks into place.
  6. Replace Panel Cover: Once the breaker is securely installed and all wiring is checked, replace the load center cover.
  7. Re-energize Panel: Turn the main service disconnect back to the ON position.

Note: If you are unsure about any step, consult a qualified electrician.

5. Operating the Circuit Breaker

The WASOTO HOM250CP circuit breaker has two operating positions and a tripped state:

  • ON Position: The lever is fully pushed towards the 'ON' marking. This allows electricity to flow through the circuit.
  • OFF Position: The lever is fully pushed towards the 'OFF' marking. This manually interrupts the flow of electricity to the circuit.
  • TRIPPED Position: When an overload or short circuit occurs, the breaker automatically moves to an intermediate position (often between ON and OFF, or fully OFF depending on the design) to interrupt the circuit. This is indicated by the 'TRIP' or 'COMMON TRIP' marking becoming visible or the lever being in a central position.

Resetting a Tripped Breaker:

  1. Identify Cause: Determine and correct the cause of the trip (e.g., unplug overloaded appliances, fix short circuits).
  2. Turn OFF: Firmly push the breaker lever all the way to the 'OFF' position. You may feel a click.
  3. Turn ON: Firmly push the breaker lever all the way to the 'ON' position.
  4. If the breaker immediately trips again, do not attempt to reset it further. Consult a qualified electrician.

6. Maintenance

Circuit breakers generally require minimal maintenance. However, periodic inspection is recommended:

  • Visual Inspection: Annually inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. Ensure the levers move freely.
  • Cleaning: If necessary, gently clean the exterior of the breaker with a dry, lint-free cloth. Do not use liquids or abrasive cleaners.
  • Professional Check: Consider having a qualified electrician inspect your electrical panel and circuit breakers every few years.

WARNING: Always disconnect power before performing any inspection or cleaning inside the electrical panel.

7. Troubleshooting

If your WASOTO HOM250CP circuit breaker is not functioning as expected, consider the following:

  • Breaker Trips Frequently:
    • Overload: The circuit may be drawing too much current. Unplug some devices or redistribute loads to other circuits.
    • Short Circuit: A direct connection between hot and neutral/ground wires. This requires immediate investigation by an electrician.
    • Ground Fault: Current leaking to ground. This can be dangerous and requires professional attention.
    • Faulty Appliance/Wiring: Disconnect all appliances from the circuit and try resetting. If it still trips, the issue is likely with the wiring or the breaker itself.
  • Breaker Will Not Reset:
    • Ensure you are pushing the lever fully to the 'OFF' position before attempting to push it to 'ON'.
    • If there is a persistent fault (overload or short circuit), the breaker will not stay in the 'ON' position. Address the underlying issue.
    • The breaker itself may be faulty and require replacement.
  • No Power to Circuit (Breaker ON):
    • Check for loose connections at the breaker terminals or within the circuit.
    • Verify the main power to the panel is on.
    • The breaker may be faulty internally.

For persistent issues or if you are uncomfortable performing these checks, contact a qualified electrician.

8. Technical Specifications

SpecificationValue
BrandWASOTO
Model Number3592426 (HOM250CP)
Current Rating50 Amps
Circuit Breaker TypeStandard (Magnetic Thermal)
Mounting TypePlug-In Mount
Number Of Poles2
Voltage Rating120/240 V~
Interrupting Capacity10 kA
Package Dimensions4.17 x 4.17 x 2.32 inches
Item Weight11.36 ounces
ManufacturerYour One Source
Date First AvailableJanuary 12, 2017

9. Warranty and Support

Warranty information for the WASOTO HOM250CP circuit breaker is typically provided at the point of purchase or can be obtained directly from the manufacturer, WASOTO. Please retain your proof of purchase for warranty claims.

For technical support or further assistance, please contact WASOTO customer service through their official channels. Always refer to the model number (HOM250CP) and item model number (3592426) when seeking support.

© 2023 WASOTO. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.