1. Introduction
This user manual provides essential information for the safe and efficient operation, installation, and maintenance of the Danfoss EV220B 032U7520 Solenoid Valve. Please read this manual thoroughly before installation or operation to ensure proper use and to prevent damage or injury.
2. Safety Information
Always observe general safety precautions during installation, operation, and maintenance. Failure to follow these instructions may result in serious injury or property damage.
- Ensure power is disconnected before any installation or maintenance work.
- Only qualified personnel should perform installation and service.
- Verify that the valve's specifications match the system requirements (pressure, temperature, medium).
- Protect the valve from physical damage and extreme environmental conditions.
3. Product Description
The Danfoss EV220B 032U7520 is a robust 2/2-way servo-operated solenoid valve designed for use in various industrial applications. It features a 1/2 inch NPT connection and is suitable for neutral media. The valve is constructed from durable metal, ensuring long-term reliability.

Figure 3.1: Danfoss EV220B 032U7520 Solenoid Valve. This image shows the brass body of the valve with a threaded inlet/outlet and the cylindrical solenoid coil assembly extending upwards from the top.
Key Features:
- Model: 032U7520
- Connection Size: 1/2 inch NPT
- Valve Type: 2/2-way, servo-operated
- Material: Metal (Brass body)
- Application: Suitable for neutral media
4. Setup and Installation
Proper installation is crucial for the valve's performance and longevity. Follow these steps carefully:
- Preparation:
- Ensure the system is depressurized and drained.
- Clean the pipe threads to remove any debris or sealant residue.
- Verify that the flow direction arrow on the valve body matches the system flow.
- Mounting:
- Mount the valve in a position where it is easily accessible for maintenance.
- The valve can be mounted in any position, but mounting with the coil upwards is recommended for optimal performance and lifespan.
- Use appropriate thread sealant on the NPT connections.
- Tighten the valve securely into the piping system, avoiding overtightening which can damage the threads or valve body.
- Electrical Connection:
- Connect the solenoid coil to the appropriate power supply as specified on the coil label.
- Ensure all electrical connections are secure and insulated to prevent short circuits.
- Adhere to local electrical codes and regulations.
- System Check:
- After installation, slowly pressurize the system and check for leaks.
- Test the valve's operation by applying and removing power to the coil.
5. Operating Instructions
The Danfoss EV220B 032U7520 is a normally closed (NC) solenoid valve, meaning it is closed when de-energized and opens when energized.
- Energizing the Coil: When electrical power is supplied to the solenoid coil, it creates a magnetic field that pulls the plunger, opening the valve and allowing fluid to flow.
- De-energizing the Coil: When power is removed from the coil, the magnetic field collapses, and a spring forces the plunger back to its original position, closing the valve and stopping fluid flow.
- Manual Override (if applicable): Some models may feature a manual override. Refer to specific product documentation if a manual override is present and how to use it safely. This model typically does not include a manual override.
Ensure the operating voltage and frequency match the coil's specifications to prevent damage and ensure proper function.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your solenoid valve. Always disconnect power before performing any maintenance.
- Cleaning: Periodically inspect the valve for dirt, debris, or corrosion. Clean the exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Leak Checks: Regularly check all connections for signs of leaks. Tighten connections if necessary, but do not overtighten.
- Coil Inspection: Inspect the solenoid coil for any signs of damage, overheating, or discoloration. Replace the coil if any damage is observed.
- Internal Inspection (Advanced): For internal component inspection or replacement (e.g., diaphragm, plunger), it is recommended to consult a qualified technician or refer to detailed service manuals provided by Danfoss. Ensure the system is fully depressurized and drained before opening the valve.
7. Troubleshooting
This section provides solutions to common issues. For problems not listed here, contact Danfoss technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Valve does not open when energized. |
|
|
| Valve does not close when de-energized. |
|
|
| Leakage from connections. |
|
|
8. Specifications
Detailed technical specifications for the Danfoss EV220B 032U7520 Solenoid Valve:
- Model Number: 032U7520
- Part Number: G032U7520
- Valve Type: 2/2-way, Servo-operated, Normally Closed (NC)
- Connection Size: 0.5 Inches NPT (National Pipe Tapered)
- Number of Ports: 2
- Material: Metal (Brass body)
- Item Weight: Approximately 11 ounces (0.69 LBR)
- Product Dimensions (L x W x H): 2.5 x 3.75 x 2.13 inches
- UPC-EAN: 5702423044412
- Manufacturer: Danfoss
- First Available: December 14, 2016
9. Warranty and Support
For specific warranty information regarding the Danfoss EV220B 032U7520 Solenoid Valve, please refer to the documentation provided with your purchase or visit the official Danfoss website. Warranty terms typically cover manufacturing defects for a specified period.
For technical support, service, or spare parts, please contact your authorized Danfoss distributor or visit the Danfoss global support portal. Provide the model number (032U7520) and serial number (if applicable) when seeking support.
Danfoss Official Website: www.danfoss.com