SEAFLO SFSP1-L016-01

SEAFLO SFSP1-L016-01 12V Submersible Pump Instruction Manual

Model: SFSP1-L016-01 | Brand: SEAFLO

1. Introduction

This manual provides essential information for the safe and efficient operation of your SEAFLO SFSP1-L016-01 12V Submersible Pump. Please read it thoroughly before installation and use to ensure proper function and longevity of the product.

The SEAFLO SFSP1-L016-01 is a robust 12-volt submersible pump designed for various applications, including marine, RV, bottled water systems, and camping. It features quiet, vibration-free operation and is constructed from food-grade materials, making it safe for potable water transfer. Its compact and lightweight design ensures easy installation and portability.

SEAFLO SFSP1-L016-01 12V Submersible Pump with ruler for scale
Figure 1: SEAFLO SFSP1-L016-01 12V Submersible Pump. This image shows the compact design of the pump next to a ruler, indicating its small size and ease of handling.

2. Safety Information

Adhering to these safety guidelines is crucial for preventing injury and damage to the pump.

  • Always disconnect power before performing any installation, maintenance, or inspection tasks on the pump.
  • Ensure the power source voltage (12V DC) matches the pump's requirements. Incorrect voltage can damage the pump.
  • The pump is designed for submersible use only. Do not run the pump dry for extended periods, as this can lead to overheating and premature failure.
  • Do not use this pump to transfer flammable liquids, corrosive chemicals, or liquids with temperatures exceeding 60°C (140°F).
  • Keep all electrical connections dry and protected from water ingress to prevent electrical hazards.
  • Ensure proper ventilation if the pump is used in an enclosed space, although it is designed for quiet operation.

3. Product Features

The SEAFLO SFSP1-L016-01 pump offers the following key features:

  • High Capacity: Delivers up to 16 liters per minute (4.2 GPM) of flow.
  • Low Voltage Operation: Operates efficiently on 12 Volts DC power.
  • Efficient Power Consumption: Maximum current draw of 5.0 Amperes.
  • Significant Delivery Height: Capable of pumping vertically up to 5.5 meters (18 feet) and a total head of 6 meters (19.7 feet).
  • Standard Hose Connection: Features a 12 mm (1/2 inch) diameter hose outlet.
  • Durable Cable: Equipped with a 1-meter long, 18 AWG electrical cable.
  • Food-Grade Construction: Manufactured from materials safe for contact with potable water.
  • Quiet and Vibration-Free: Engineered for minimal noise and smooth operation.
  • Maintenance-Free Seal: Features a dry seal with permanent lubrication.
  • Fully Submersible: Designed to operate completely submerged in liquid.
  • Continuous Operation: Can operate continuously for up to 30 minutes.
Diagram showing features and benefits of SEAFLO SFSP1-L016-01 pump
Figure 2: Features and Benefits of the SEAFLO SFSP1-L016-01 pump. This diagram highlights key attributes such as delivery height, operating time, hose connection, and submersible design.

4. Specifications

SpecificationValue
ModelSFSP1-L016-01
BrandSEAFLO
Voltage12V DC
Max Flow Rate16 LPM (4.2 GPM)
Max Current Draw5.0 Amperes
Working Pressure0.6 Bar (8.7 PSI)
Max Delivery Height (Vertical)5.5 meters (18 feet)
Max Total Head6 meters (19.7 feet)
Outlet Diameter1/2 inch (12 mm)
Cable Length1 meter (18 AWG)
MaterialDurable Food-Grade Plastic
Operating Time30 minutes continuous
Net Weight0.24 kg
Dimensional drawing of SEAFLO SFSP1-L016-01 pump
Figure 3: Dimensional drawing of the SEAFLO SFSP1-L016-01 pump. This image provides key measurements for installation planning.

5. Installation

Follow these steps for proper installation of your submersible pump:

  1. Mounting: Place the pump in the desired location, ensuring it will be fully submerged in the liquid to be pumped during operation. The pump's compact design allows for flexible placement.
  2. Hose Connection: Connect a 12 mm (1/2 inch) inner diameter hose to the pump's outlet port. Secure the hose firmly with a hose clamp to prevent leaks and ensure a tight seal.
  3. Electrical Connection: Connect the pump's 1-meter 18 AWG cable to a 12V DC power source. Ensure correct polarity: the red wire connects to the positive (+) terminal, and the black wire connects to the negative (-) terminal. Use appropriate waterproof connectors and ensure all electrical connections are secure and protected from moisture.
  4. Power Source: The pump can be powered by a suitable 12V DC source, such as a marine battery, RV battery, or a solar power system. Verify that your power source can reliably supply the pump's maximum current draw of 5.0 Amperes.

6. Operation

To operate the SEAFLO SFSP1-L016-01 pump:

  • Once the pump is correctly installed and all connections are secure, apply 12V DC power to the pump. The pump will immediately begin to transfer liquid.
  • The pump is designed for continuous operation for up to 30 minutes. If longer operation is required, allow for cooling periods between cycles to prevent overheating and extend the pump's lifespan.
  • Always ensure the pump remains fully submerged in the liquid during operation. Running the pump dry can cause damage to the motor and seals.

7. Maintenance

The SEAFLO SFSP1-L016-01 pump is designed for low maintenance, but regular checks will ensure optimal performance:

  • Inspection: Periodically inspect the pump body, hose connections, and electrical wiring for any signs of wear, damage, or leaks. Replace any damaged components immediately.
  • Cleaning: Regularly clean the pump's intake screen to prevent blockages from debris, which can reduce flow rate and strain the motor. Disconnect power before cleaning.
  • Lubrication: The pump features a dry seal with permanent lubrication, meaning no external lubrication is required.
  • Potable Water Use: If the pump is used for potable water, flush the pump and hoses with clean, fresh water after each use to prevent bacterial growth and maintain water quality.

8. Troubleshooting

Refer to the following table for common issues and their solutions:

ProblemPossible CauseSolution
Pump not runningNo power supply
Incorrect wiring polarity
Blown fuse or tripped breaker
Check power connections and ensure 12V DC is supplied.
Verify red wire to positive, black to negative.
Check and replace fuse or reset breaker.
Low flow or no flowBlocked intake screen
Pump not fully submerged (drawing air)
Kinked or restricted hose
Leaks in hose connections
Clean intake screen.
Ensure pump is fully submerged.
Straighten hose; check for obstructions.
Tighten hose clamps; replace damaged hose.
Excessive noise or vibrationPump not securely placed
Debris inside pump
Ensure pump is stable and not vibrating against surfaces.
Disconnect power, inspect and remove any debris from the impeller area.

9. Warranty and Support

SEAFLO products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your authorized SEAFLO dealer. Keep your purchase receipt as proof of purchase for any warranty claims.

For technical assistance or further inquiries, please contact your SEAFLO dealer or visit the official SEAFLO website for support resources.

© 2024 SEAFLO. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.