SE ELECTRONICS V3

SE ELECTRONICS V3 Handheld Cardioid Microphone

Model: V3

Introduction

The SE ELECTRONICS V3 is a robust, all-purpose handheld dynamic microphone designed for clear and reliable audio capture. Featuring a cardioid polar pattern, it is optimized for vocal and speech applications, effectively rejecting off-axis sound. Its durable construction ensures consistent performance in various environments.

What's in the Box

  • V3 Handheld Cardioid Microphone
  • Microphone Clip
  • Spare Internal Windscreen
  • Thread Adapter
  • Pouch

Key Features

  • Frequency Range: 50Hz to 16kHz
  • Neodymium Magnet: For high output and consistent performance
  • Copper Voice Coil: Ensures clear signal transmission
  • Sensitivity: 2.5mV/Pa
  • Impedance: 600 ohms
  • Unidirectional Polar Pattern: Focuses on sound from the front, reducing background noise
  • Durable Construction: Made from Alloy Steel, Copper, and Zinc

Setup

Follow these steps to set up your SE ELECTRONICS V3 microphone:

  1. Attach Microphone Clip: Securely screw the provided microphone clip onto a standard microphone stand.
  2. Mount Microphone: Insert the V3 microphone into the microphone clip. Ensure it is firmly seated.
  3. Connect XLR Cable: Connect a standard XLR cable to the microphone's XLR output port at the base. Connect the other end of the XLR cable to your audio interface, mixer, or compatible device.
  4. Power On: Ensure your connected audio device is powered on and configured to receive input from the microphone. The V3 is a dynamic microphone and does not require phantom power.
Close-up view of the SE ELECTRONICS V3 microphone's base, showing the threaded connection for the microphone clip and the XLR input area.
This image displays the lower part of the SE ELECTRONICS V3 microphone, highlighting the robust construction and the standard threading for attaching a microphone clip. The area for the XLR cable connection is also visible, indicating the microphone's wired nature.

Operating Instructions

The V3 microphone is designed for optimal performance in singing and speech applications. Its unidirectional (cardioid) polar pattern means it is most sensitive to sounds coming from directly in front of it, and least sensitive to sounds from the sides and rear. This helps to minimize background noise and feedback.

  • Microphone Placement: For vocals, hold the microphone approximately 2-6 inches from your mouth. Experiment with distance to achieve the desired tone and to control plosives (harsh 'p' and 'b' sounds).
  • Gain Staging: Adjust the gain on your mixer or audio interface to achieve a strong signal without clipping (distortion). Start with the gain low and gradually increase it while speaking or singing into the microphone.
  • Feedback Control: Due to its cardioid pattern, aim the microphone away from loudspeakers or monitors to reduce the chance of feedback.
  • Handling Noise: While the V3 is designed for durability, excessive handling can introduce noise. For stationary use, a microphone stand is recommended.

Maintenance

Proper care will extend the life and performance of your V3 microphone:

  • Cleaning: Use a soft, dry cloth to wipe the microphone body. For the grille, you can gently brush away debris. Avoid using liquid cleaners directly on the grille or capsule.
  • Storage: When not in use, store the microphone in its provided pouch to protect it from dust and physical damage.
  • Environmental Conditions: Avoid exposing the microphone to extreme temperatures, high humidity, or direct moisture.
  • Cable Care: Always disconnect XLR cables by gripping the connector, not the cable itself, to prevent damage to the pins and cable.

Troubleshooting

If you encounter issues with your V3 microphone, consider the following:

  • No Sound:
    • Ensure the XLR cable is securely connected at both the microphone and the audio device.
    • Verify that the input channel on your mixer or interface is selected and its gain is appropriately set.
    • Test with a different XLR cable or audio input channel if available.
  • Low Volume or Weak Signal:
    • Increase the gain on your audio device.
    • Ensure the microphone is positioned correctly and close enough to the sound source.
    • Check that the microphone's impedance (600 ohms) is compatible with your audio input.
  • Distorted Sound:
    • Reduce the gain on your audio device.
    • Ensure the microphone is not overloaded by excessively loud sound sources.
  • Excessive Background Noise or Feedback:
    • Reposition the microphone to point directly at the sound source and away from noise sources or loudspeakers.
    • Adjust monitor levels or speaker placement.

Specifications

SpecificationValue
Model NameV3
Microphone Form FactorHandheld
Polar PatternUnidirectional (Cardioid)
Frequency Response50Hz - 16kHz
Audio Sensitivity2.5mV/Pa
Impedance600 Ohms
Signal-to-Noise Ratio78 dB
Connectivity TechnologyXLR
Power SourceCorded Electric (No phantom power required)
MaterialAlloy Steel, Copper, Zinc
Item Weight0.51 Kilograms (1.12 pounds)
Product Dimensions (L x W x H)9.25 x 4.13 x 3.15 inches
Recommended UsesSinging, Speech
Date First AvailableNovember 17, 2016

Warranty and Support

For warranty information and technical support, please refer to the official SE ELECTRONICS website or contact your authorized dealer. Keep your proof of purchase for any warranty claims.

You can visit the official SE ELECTRONICS store for more information: SE ELECTRONICS Store

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.