1. Introduction
Thank you for choosing the Matala HK25LP Hakko Linear Air Pump. This manual provides essential information for the safe and efficient operation, installation, maintenance, and troubleshooting of your air pump. Please read this manual thoroughly before operating the unit and keep it for future reference.
The HK25LP is designed to provide reliable and consistent aeration for various applications, including pond filtration, aquaculture, and wastewater treatment. Its linear diaphragm mechanism ensures quiet operation and energy efficiency.
2. Safety Instructions
Always observe the following safety precautions to prevent injury or damage to the unit:
- Electrical Safety: Ensure the power supply matches the pump's requirements (voltage, frequency). Always connect the pump to a grounded outlet. Do not operate with a damaged power cord or plug.
- Water Proximity: This pump is not submersible. Always install the pump in a dry, well-ventilated area, protected from direct rain, splashes, and flooding. The pump must be placed above the water level to prevent back-siphoning.
- Ventilation: Ensure adequate airflow around the pump to prevent overheating. Do not cover the pump or block its ventilation openings.
- Handling: Do not lift or carry the pump by its power cord.
- Maintenance: Disconnect power before performing any maintenance or cleaning. Only use genuine Hakko replacement parts.
- Children and Pets: Keep the pump out of reach of children and pets.
3. Setup
3.1 Unpacking
Carefully remove the air pump and all accessories from the packaging. Inspect the unit for any signs of damage during transit. If damage is found, contact your supplier immediately.
3.2 Placement
Select a suitable location for the air pump:
- Dry and Protected: The pump must be installed in a dry, sheltered location, away from direct sunlight, rain, and excessive dust.
- Above Water Level: Always place the pump above the highest water level of your pond or application to prevent water from siphoning back into the pump. If this is not possible, install a check valve on the air line.
- Ventilation: Ensure the area has good air circulation to prevent overheating. Maintain at least 6 inches (15 cm) of clear space around all sides of the pump.
- Stable Surface: Place the pump on a flat, stable surface to minimize vibration and noise.
3.3 Air Line Connection
Connect the appropriate size air hose (typically 3/4 inch or 1 inch) to the pump's outlet nozzle. Secure the hose with a clamp if necessary. Run the air hose to your air diffusers or air stones in the pond or application.

An image showing the Matala HK25LP Hakko Linear Air Pump, a compact, light-grey rectangular unit with the 'Matala' logo on top and an air outlet on the side. This illustrates the general appearance of the pump.
3.4 Electrical Connection
Plug the power cord into a properly grounded electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for outdoor or wet environments.
4. Operation
4.1 Initial Startup
Once all connections are secure and the pump is properly placed, plug in the power cord. The pump should start operating immediately, producing air from the diffusers/stones.
4.2 Continuous Operation
The Hakko HK25LP is designed for continuous operation. Monitor the air output and ensure the pump is running smoothly. Periodically check for any unusual noises or vibrations.
4.3 Air Flow Adjustment (if applicable)
If your setup includes an air manifold with individual valves, you can adjust the airflow to specific diffusers as needed. Do not restrict the overall airflow excessively, as this can put strain on the pump.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your air pump. Always disconnect power before performing any maintenance.
5.1 Air Filter Cleaning/Replacement
The air filter sponge prevents dust and debris from entering the pump. Check and clean the filter sponge every 3-6 months, or more frequently in dusty environments. To clean, remove the filter cover, take out the sponge, wash it with clean water, and allow it to dry completely before reinserting. Replace the filter sponge annually or if it shows signs of deterioration.
5.2 Diaphragm Replacement
The diaphragms are wear-and-tear components and typically need replacement every 12-18 months, depending on usage and environmental conditions. Reduced airflow or increased noise are indicators that the diaphragms may need replacement. Refer to the specific diaphragm replacement kit instructions for detailed steps. It is recommended to use genuine Hakko replacement parts.
5.3 General Cleaning
Keep the exterior of the pump clean and free of dust and debris. Use a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
6. Troubleshooting
Before contacting customer support, please refer to the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump not running / No air output | No power supply Damaged power cord/plug Internal component failure | Check power outlet and GFCI Inspect cord/plug for damage; replace if necessary Contact customer support |
| Low air output | Clogged air filter Worn diaphragms Blocked air line/diffuser Excessive back pressure | Clean or replace air filter Replace diaphragms Check and clear air line/diffuser Reduce depth of air stones or number of diffusers |
| Excessive noise or vibration | Loose components Worn diaphragms Pump not on stable surface | Check for loose screws; tighten if found Replace diaphragms Ensure pump is on a flat, stable surface |
| Pump overheating | Poor ventilation Blocked air filter Excessive back pressure | Ensure adequate clear space around pump Clean or replace air filter Reduce back pressure |
If the problem persists after attempting these solutions, please contact Hakko customer support.
7. Specifications
| Specification | Value |
|---|---|
| Brand | Hakko |
| Model | HK25LP |
| Material | Resin |
| Power Source | Corded Electric |
| Air Flow Capacity | 32 LPM (Liters Per Minute) |
| Operation Mode | Automatic |
| Manufacturer | Matala |
| ASIN | B01M63XJKW |
| UPC | 696447524133 |
8. Warranty and Support
This Hakko air pump is covered by a manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product for specific terms and conditions, including warranty period and coverage details.