finder 12.11.8.230.0000
FINDER 12.11.8.230.0000 Programmable Timer Instruction Manual
Model: 12.11.8.230.0000 | Brand: FINDER
1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your FINDER 12.11.8.230.0000 Programmable Timer. Please read this manual carefully before using the device to ensure safe and efficient operation.
2. Safety Information
Warning: Electrical installation should only be performed by qualified personnel. Disconnect power before installation or maintenance. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure the power supply matches the device's specifications (230VAC).
- Do not expose the device to moisture or extreme temperatures.
- Do not attempt to repair or modify the device yourself. Contact qualified service personnel.
3. Product Overview
The FINDER 12.11.8.230.0000 is a daily/weekly programmable timer designed for DIN rail mounting. It features a 15-minute to 24-hour timing range and a SPST-NO (Single Pole Single Throw - Normally Open) contact configuration, capable of switching up to 16A at 250VAC.

Figure 1: Front view of the FINDER 12.11.8.230.0000 Programmable Timer. This image shows the timer module with its transparent cover, revealing the time setting dial and indicators. The electrical connection terminals are visible at the top, and wiring diagrams (N, M, L, 1, 2, 3) are printed on the lower front face.
Key Components:
- Time Setting Dial: Used to set the desired ON/OFF periods.
- Manual Override Switch: Allows temporary manual control (ON/OFF) independent of the programmed schedule.
- Connection Terminals: For power input (L, N) and load connection (1, 2, 3 for SPST-NO contact).
- Transparent Cover: Protects the setting dial and indicators.
4. Setup and Installation
4.1 Mounting
The timer is designed for DIN rail mounting. Securely attach the device to a standard 35mm DIN rail within an electrical enclosure.
4.2 Wiring Diagram
Refer to the wiring diagram printed on the device and follow local electrical codes. Ensure all connections are tight and secure.
- L: Live input (230VAC)
- N: Neutral input
- 1: Common terminal for the switch contact
- 2: Normally Open (NO) terminal for the switch contact
- 3: (If present, typically for internal motor or additional contact, refer to specific product markings)
Connect the load to terminals 1 and 2. When the timer activates, the contact between 1 and 2 will close, supplying power to the load.
5. Operating Instructions
5.1 Setting the Current Time
- Rotate the main time setting dial (usually marked with hours 0-24) clockwise until the current time aligns with the reference arrow or marker on the timer's body.
5.2 Programming ON/OFF Periods
The timer typically uses small segments or pins around the dial to set ON/OFF times. Each segment usually represents a 15-minute interval.
- To set an "ON" period, push the corresponding segments outwards.
- To set an "OFF" period, leave the corresponding segments pushed inwards.
- Ensure that the total ON/OFF periods cover the desired 24-hour cycle.
5.3 Manual Override
The timer may have a manual override switch (often labeled with symbols like 'I', 'O', or a clock icon). This switch allows you to temporarily bypass the programmed schedule.
- 'I' (ON): Forces the output ON, regardless of the program.
- 'O' (OFF): Forces the output OFF, regardless of the program.
- Clock Symbol (AUTO): Returns control to the programmed schedule.
6. Maintenance
The FINDER 12.11.8.230.0000 timer is designed for maintenance-free operation. However, periodic checks are recommended:
- Ensure the device is free from dust and debris.
- Verify that all electrical connections remain secure.
- Check for any signs of overheating or damage.
For cleaning, use a dry, soft cloth. Do not use abrasive cleaners or solvents.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Timer not switching ON/OFF | No power supply; Incorrect wiring; Manual override engaged; Incorrect program setting. | Check power supply; Verify wiring against diagram; Set manual override to AUTO; Recheck program segments. |
| Load not receiving power | Faulty load; Loose connections; Overload protection tripped. | Test the load independently; Tighten all connections; Check circuit breaker/fuse. |
| Timer runs continuously ON/OFF | Manual override engaged; Internal fault. | Set manual override to AUTO; If problem persists, contact support. |
8. Specifications
- Model Number: 12.11.8.230.0000
- Brand: FINDER
- Function: Programmable Time Switch (15min-24h)
- Contact Type: SPST-NO (Single Pole Single Throw - Normally Open)
- Contact Rating: 16A / 250VAC
- Supply Voltage: 230VAC
- Mounting: DIN Rail
- ASIN: B01LZY31HX
9. Support and Warranty
For technical support or warranty inquiries, please contact your retailer or the official FINDER customer service. Keep your purchase receipt as proof of purchase.
Information regarding spare parts availability is currently unavailable. Please consult with your supplier for further details.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.