1. Product Overview

The Lutron Maestro Occupancy Detection Switch (MS-OPS2H-WH) integrates a standard light switch with a passive infrared (PIR) occupancy sensor. This device is designed to automatically control lighting based on the presence or absence of occupants in a room. The sensor detects the heat signatures of moving individuals within its detection zone, activating or deactivating the connected load (e.g., lights) accordingly.

Lutron MS-OPS2H-WH Occupancy Sensor Switch, front view

Figure 1: Front view of the Lutron MS-OPS2H-WH Occupancy Sensor Switch.

2. Safety Information

WARNING: Risk of Electric Shock. Improper installation can result in serious injury or death. Always turn off power at the circuit breaker or fuse box before installing or servicing this device. This product must be installed by a qualified electrician in accordance with all local and national electrical codes.

  • Do not use with loads exceeding the specified ratings.
  • Install indoors only.
  • Ensure all wire connections are secure and properly insulated.
  • Grounding is required for safe operation.

3. Installation (Setup)

  1. Turn Off Power: Locate the circuit breaker or fuse that controls the power to the switch location. Turn it OFF. Verify power is off by attempting to turn on the light controlled by the switch.
  2. Remove Existing Switch: Carefully remove the wall plate and unscrew the existing switch from the wall box. Disconnect the wires from the old switch, noting which wire was connected to which terminal.
  3. Wire the New Switch: Connect the wires from the wall box to the Lutron MS-OPS2H-WH switch according to the wiring diagram provided with the product packaging. Typically, this involves connecting the hot (line), load, neutral (if present), and ground wires. Ensure all connections are tight.
  4. Mount the Switch: Gently push the wired switch into the wall box. Secure it with the provided screws.
  5. Attach Wall Plate: Install the decorative wall plate over the switch.
  6. Restore Power: Turn the power back ON at the circuit breaker or fuse box.

Note: If you are unsure about any wiring steps, consult a qualified electrician.

4. Operation

The MS-OPS2H-WH switch operates in two primary modes: Occupancy Sensing and Vacancy Sensing. The default mode is typically Occupancy Sensing (lights turn ON automatically when motion is detected and OFF when the room is vacant).

  • Automatic ON/OFF: In Occupancy mode, the sensor detects movement and automatically turns the connected lights ON. After a preset time delay with no detected motion, the lights will automatically turn OFF.
  • Manual ON/Automatic OFF: In Vacancy mode, the lights must be turned ON manually by pressing the switch button. They will then turn OFF automatically after a preset time delay with no detected motion.
  • Manual Control: You can manually turn the lights ON or OFF at any time by pressing the large paddle switch.

Refer to the detailed instructions included in the product packaging for information on adjusting sensitivity and time-out settings, as these may vary by model revision.

5. Maintenance

The Lutron MS-OPS2H-WH switch requires minimal maintenance.

  • Cleaning: To clean the surface of the switch and wall plate, use a soft, damp cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the finish or internal components.
  • Obstruction: Ensure the sensor lens is not obstructed by furniture, decorations, or other objects, as this can impair its ability to detect motion.

6. Troubleshooting

Problem Possible Cause Solution
Lights do not turn ON automatically.
  • Power is OFF.
  • Incorrect wiring.
  • Sensor lens obstructed.
  • Switch is in Vacancy mode.
  • Check circuit breaker.
  • Verify wiring connections.
  • Clear obstructions from sensor.
  • Change operating mode to Occupancy.
Lights turn OFF too quickly or too slowly.
  • Time-out setting is incorrect.
  • Sensor sensitivity is too low/high.
  • Adjust the time-out setting.
  • Adjust sensor sensitivity.
Lights turn ON/OFF unexpectedly.
  • Drafts or heat sources in detection zone.
  • Sensor sensitivity too high.
  • Relocate heat sources or adjust sensor placement.
  • Reduce sensor sensitivity.

If problems persist after attempting these solutions, contact Lutron Technical Support.

7. Specifications

  • Model Number: MS-OPS2H-WH
  • Brand: Lutron
  • Color: White
  • Power Source: Corded Electric
  • Mounting Type: Wall Mount
  • Product Dimensions: 5.8 x 3.8 x 2 inches
  • Item Weight: 1.28 ounces
  • Operating Temperature: 68 Degrees Fahrenheit (20 Degrees Celsius)
  • Compatible Devices: Light fixtures
  • UPC: 027557983136

8. Warranty and Support

Lutron products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Lutron website. For technical assistance, troubleshooting, or product inquiries, please contact Lutron Customer Service.

Lutron Customer Service:

  • Visit www.lutron.com/support for online resources.
  • Contact information for phone support can be found on the Lutron website.

Related Documents - MS-OPS2H-WH

Preview Lutron Maestro Occupancy/Vacancy Sensor Switch: Specifications, Features, and Wiring Diagrams
Comprehensive specifications, features, advanced XCT Technology, custom settings, selection matrix, dimensions, mounting, operation, and detailed wiring diagrams for the Lutron Maestro Occupancy/Vacancy Sensor Switch. Learn about its energy-saving capabilities and installation options.
Preview Lutron Maestro Occupancy/Vacancy Sensing Switch - Product Specifications and Installation Guide
Detailed specifications, features, installation instructions, and wiring diagrams for the Lutron Maestro Occupancy and Vacancy Sensing Switches, designed for energy-efficient lighting control.
Preview Lutron Occupancy Sensing Switch Installation Guide
A comprehensive guide for installing the Lutron Occupancy Sensing Switch (MS-OPS2, MS-VPS2), covering wiring, setup, and troubleshooting.
Preview Lutron Radio Powr Savr Wireless Occupancy/Vacancy Ceiling Sensor Specifications
Comprehensive specifications, features, and installation details for the Lutron Radio Powr Savr Wireless Occupancy/Vacancy Ceiling Sensor, a battery-powered PIR sensor for automated lighting control.
Preview Lutron Maestro Occupancy Sensing Switch Installation Guide
Detailed installation instructions and specifications for the Lutron Maestro MS-OPS2 and MS-VPS2 occupancy sensing switches. Covers wiring, custom settings, important safety notes, and limited warranty information.
Preview Lutron MAESTRO MS-OPS5M/MS-VPS5M Occupancy Sensor Switch Installation and Configuration Guide
Comprehensive guide for installing and configuring the Lutron MAESTRO MS-OPS5M and MS-VPS5M occupancy sensor switches. Learn about features, wiring, custom settings, and important safety notes.