Introduction
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Danfoss 077F1454BJ Temperature Control. Please read this manual thoroughly before attempting to install or operate the device. Retain this manual for future reference.
Product Overview
The Danfoss 077F1454BJ is a robust temperature control unit designed for various industrial and scientific applications. It features a remote control capability and is hardwired for power. The system includes a main control module, a connecting cable, and a rotary knob for temperature adjustment.

Figure 1: Danfoss 077F1454BJ Temperature Control system components. This image displays the Danfoss 077F1454BJ Temperature Control system. It includes the main control module, a long coiled white cable with connectors, and a separate black rotary control knob with numerical markings from 0 to 9.
Specifications
| Feature | Detail |
|---|---|
| Brand | Danfoss |
| Model Number | 46-1652 |
| Controller Type | Remote Control |
| Special Feature | Remote |
| Color | White |
| Temperature Control Type | Remote |
| Included Components | 1 x Cable |
| Power Source | Hardwire |
| Item Weight | 1.18 Pounds |
| Voltage | 24 Volts |
| Display Type | LED |
| Control Method | Remote |
| Mounting Type | Floor Mount |
| UPC | 254616526007 |
Setup and Installation
Important: Installation should only be performed by qualified personnel in accordance with all local and national electrical codes. Ensure power is disconnected before beginning installation.
- Safety First: Disconnect all power to the circuit where the temperature control will be installed. Verify with a voltage tester.
- Mounting: The control unit is designed for floor mounting. Secure the main control module in a suitable, accessible location, ensuring it is protected from moisture and extreme temperatures.
- Wiring: Connect the provided cable to the control module and the system it is intended to regulate. Refer to the wiring diagram specific to your application (not included in this general manual). The unit requires a 24 Volt hardwire power source. Ensure all connections are secure and properly insulated.
- Remote Sensor Placement: If applicable, position the remote temperature sensor (part of the cable assembly) in the area where temperature is to be monitored and controlled. Avoid placing it near heat sources or drafts that could provide inaccurate readings.
- Control Knob Installation: Attach the rotary control knob to its designated shaft on the control module. Ensure it is firmly seated and rotates smoothly.
- Power On: Once all connections are verified and secure, restore power to the circuit.
Operating Instructions
The Danfoss 077F1454BJ Temperature Control operates via its remote control functionality, primarily through the rotary knob.
- Power Indicator: Upon power-up, the LED display on the control module should illuminate, indicating the unit is active.
- Setting Temperature: Rotate the black control knob to adjust the desired temperature setting. The numerical markings (0-9) on the knob correspond to different temperature levels. Consult your system's specific documentation for the exact temperature range associated with each setting.
- Monitoring: The control unit will continuously monitor the temperature via its remote sensor and activate/deactivate the connected system (e.g., heating or cooling) to maintain the set temperature.
- Adjustments: Make small adjustments to the control knob and allow sufficient time for the system to respond and stabilize before making further changes.
Maintenance
The Danfoss 077F1454BJ Temperature Control is designed for minimal maintenance. Regular checks can ensure optimal performance.
- Cleaning: Periodically clean the exterior of the control module and the remote sensor with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the unit is powered off before cleaning.
- Connections: Annually inspect all wiring connections for tightness and signs of wear or corrosion. Address any issues promptly.
- Sensor Check: Ensure the remote sensor is free from obstructions and debris that could affect its accuracy.
- Environmental Conditions: Verify that the operating environment remains within the recommended temperature and humidity ranges for the device.
Troubleshooting
If you experience issues with your Danfoss 077F1454BJ Temperature Control, refer to the following common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not powering on (LED off) | No power supply; loose wiring; faulty unit. | Check power source and circuit breaker. Verify all hardwire connections. If power is present and connections are secure, contact support. |
| Incorrect temperature readings | Sensor obstruction; sensor placed incorrectly; faulty sensor. | Ensure sensor is clean and clear of obstructions. Reposition sensor away from direct heat/cold sources. If problem persists, contact support. |
| System not responding to control knob | Knob not properly seated; internal fault; wiring issue. | Ensure the control knob is securely attached. Check wiring connections. If the issue continues, contact support. |
| Temperature fluctuates widely | Improper setting; environmental factors; sensor issue. | Adjust the control knob to a stable setting. Ensure the environment is stable. Check sensor placement and condition. |
For issues not listed here or if troubleshooting steps do not resolve the problem, please contact Danfoss customer support.
Warranty and Support
Danfoss products are manufactured to high-quality standards. For specific warranty information regarding your 077F1454BJ Temperature Control, please refer to the documentation provided at the time of purchase or visit the official Danfoss website.
For technical assistance, spare parts, or warranty claims, please contact Danfoss customer support:
- Website: www.danfoss.com
- Contact Information: Refer to the "Contact Us" section on the Danfoss website for regional phone numbers and email support.