Astralpool 57178

ASTRALPOOL Peristaltic Pump 12L/H 1 bar (Model 57178) Instruction Manual

1. Introduction

1.1 Product Overview

The ASTRALPOOL Peristaltic Pump, Model 57178, is designed for precise fluid dosing applications. This pump features continuous flow regulation, adjustable from 0% to 100% of its maximum capacity. Flow adjustment is managed by varying the motor speed via a potentiometer conveniently located on the pump's front panel. It is capable of delivering up to 12 liters per hour at a maximum pressure of 1 bar.

1.2 Safety Information

Please read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in personal injury or equipment damage.

  • Always disconnect power before performing any installation or maintenance.
  • Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and extreme temperatures.
  • Verify that the power supply voltage matches the pump's requirements (230 Volts AC).
  • Do not operate the pump with damaged cables or connections.
  • Wear appropriate personal protective equipment (PPE) when handling chemicals or performing maintenance.

2. Setup and Installation

2.1 Mounting the Pump

Select a stable, vertical surface for mounting the pump. Ensure there is adequate space around the pump for ventilation and access for maintenance. Use appropriate fasteners to secure the pump firmly to the chosen surface.

2.2 Electrical Connection

The pump requires a 230 Volts AC power supply. Connect the pump to a grounded electrical outlet. It is recommended to use a dedicated circuit with appropriate overcurrent protection. Consult a qualified electrician if you are unsure about electrical connections.

2.3 Fluid Connections

Identify the inlet and outlet ports on the pump. The inlet port typically draws fluid from the source, and the outlet port delivers the fluid. Connect appropriate tubing to these ports, ensuring all connections are secure and leak-free. Use tubing compatible with the fluid being pumped and capable of withstanding the operating pressure.

Astralpool Peristaltic Pump 57178 showing the transparent cover, internal tubing, and connection ports.

This image displays the Astralpool Peristaltic Pump, model 57178. The pump features a blue casing with a transparent front cover, allowing visibility of the internal peristaltic mechanism and tubing. At the bottom, two black connection ports are visible for fluid inlet and outlet.

3. Operating Instructions

3.1 Initial Start-up

  1. Ensure all fluid connections are secure and the pump is properly mounted.
  2. Verify that the fluid source is available and the discharge line is correctly routed.
  3. Plug the pump into the power supply.

3.2 Flow Regulation

The pump's flow rate is adjusted using the potentiometer located on the front panel. Rotate the potentiometer clockwise to increase the flow rate and counter-clockwise to decrease it. The flow can be continuously regulated from 0% to 100% of the pump's maximum capacity (12 L/H).

4. Maintenance

4.1 General Maintenance

  • Regularly inspect the tubing for signs of wear, cracks, or blockages. Replace tubing as necessary.
  • Check all connections for leaks and tighten if required.
  • Keep the pump's exterior clean and free from dust and debris.

4.2 Cleaning

To clean the pump, first disconnect it from the power supply. Wipe the exterior with a damp cloth. If the internal tubing requires cleaning, follow the manufacturer's guidelines for flushing the system with an appropriate cleaning solution, ensuring it is compatible with the pump materials and the fluids being handled.

5. Troubleshooting

ProblemPossible CauseSolution
Pump does not startNo power supply
Damaged power cable
Check power connection and outlet
Inspect and replace cable if damaged
No fluid flowTubing kinked or blocked
Inlet filter clogged
Potentiometer set to 0%
Inspect and clear tubing
Clean or replace inlet filter
Adjust potentiometer to desired flow rate
Inconsistent flowAir in the line
Worn tubing
Bleed air from the system
Replace peristaltic tubing
Leakage at connectionsLoose connections
Damaged seals/tubing
Tighten all connections
Inspect and replace seals or tubing

6. Technical Specifications

SpecificationValue
BrandAstralpool
Model Number57178
Product Dimensions (L x W x H)23 x 11 x 13 cm
Weight900 grams
Voltage230 Volts (AC)
Flow RateUp to 12 L/H (continuously adjustable)
Maximum Pressure1 bar
Spare Parts AvailabilityInformation unavailable

Related Documents - 57178

Preview AstralPool Halo Doser PH Dosing Module Installation Manual
Installation manual for the AstralPool Halo Doser PH Dosing Module, covering safety instructions, system overview, installation, control, maintenance, and troubleshooting.
Preview AstralPool QB800 Robotic Pool Cleaner: User Manual & Guide
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the AstralPool QB800 Robotic Pool Cleaner.
Preview ASTRALPOOL Stainless Steel Maintenance Guide for Aquatic Applications
Essential guide for maintaining ASTRALPOOL stainless steel components in aquatic environments. Learn best practices for cleaning, preventing oxidation, and ensuring longevity.
Preview AstralPool Classic Plus Multiport Valve: Installation, Maintenance, and Troubleshooting Guide
Detailed guide for the AstralPool Classic Plus multiport valve (model 73950-1000). Covers valve operations, step-by-step installation, essential maintenance procedures, a complete parts list, and common troubleshooting solutions for swimming pool filter systems.
Preview AstralPool Halo Xpand Automation Expansion Module Installation Manual
This manual provides installation instructions for the AstralPool Halo Xpand Automation Expansion Module, detailing system overview, mounting, power connections, pairing, configuration, control methods, and troubleshooting.
Preview AstralPool Viron Salt Chlorinator with Bluetooth: Installation and Operating Manual
Comprehensive installation, operation, and maintenance guide for the AstralPool Viron Salt Chlorinator with Bluetooth. Learn setup, troubleshooting, and pool chemistry management.