Introduction
This manual provides instructions for the proper setup, operation, and maintenance of your Hampton Bay CHQ7096T Remote Control. This remote is specifically designed for Hampton Bay ceiling fans that utilize the CHQ7096T system, identifiable by a YELLOW light button and a FOR/REV button in the top right position. It is not compatible with systems requiring remotes with green or red light buttons.
Setup
1. Battery Installation
- Locate the battery compartment cover on the back of the remote control.
- Slide the cover downwards to open the compartment.
- Insert four (4) AAA batteries, ensuring the positive (+) and negative (-) terminals align correctly with the markings inside the compartment.
- Replace the battery compartment cover by sliding it back into position until it clicks securely.

Figure 1: Rear view of the remote control, illustrating the battery compartment and DIP switches.
2. Setting the Dip Switches (Code Setting)
For the remote control to communicate with your ceiling fan, the dip switches on the remote must match the dip switch settings on your fan's receiver unit. This is crucial for proper operation.
- With the battery cover removed, locate the bank of four (4) dip switches (labeled 1, 2, 3, 4) inside the battery compartment.
- Identify the dip switch settings on your ceiling fan's receiver unit. This unit is typically located in the fan's canopy, above the motor housing. You may need to consult your fan's manual or a qualified electrician to access these switches.
- Using a small screwdriver or pen, adjust the dip switches on your CHQ7096T remote control to exactly match the ON/OFF positions of the dip switches on your fan's receiver.
- Once the codes match, replace the battery compartment cover.
Note: If the remote does not operate the fan after setting the switches, double-check that the remote's switches precisely match the fan receiver's switches.
Operating Instructions
Once the batteries are installed and the dip switches are set, your remote control is ready for use. Point the remote towards the ceiling fan when operating.

Figure 2: Front view of the remote control, showing button layout.
Button Functions:
- FAN AUTO: Activates or deactivates the fan's automatic mode, which may adjust fan speed based on room temperature.
- TIMER: Sets a timer for the fan to operate for a specified duration before turning off. Refer to your fan's manual for specific timer intervals.
- LIGHT DELAY: Delays the turning off of the light for a short period after the button is pressed, allowing time to exit the room.
- TEMP./SET HOUR: Used for setting the temperature threshold in AUTO mode or adjusting the hour for the fan's internal clock/timer functions.
- FOR/REV (Top Right Button): Changes the direction of the fan blades (forward for cooling, reverse for circulating warm air).
- Yellow Light Button: Controls the ceiling fan's light fixture. Press once to turn on/off, press and hold to dim/brighten (if supported by your fan's light kit).
- Fan Speed Buttons (Blue, Up/Down Arrows): Adjusts the fan speed. The blue button typically cycles through speeds (Low, Medium, High), while the up/down arrows may provide more granular control or specific speed settings.
Maintenance
Battery Replacement
When the remote control's range decreases or it becomes unresponsive, it is likely time to replace the batteries.
- Follow the "Battery Installation" steps outlined in the Setup section to open the battery compartment.
- Remove the old AAA batteries.
- Insert four new AAA batteries, observing the correct polarity.
- Securely close the battery compartment cover.
Battery Safety:
- Do not mix old and new batteries.
- Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.
- Remove batteries if the remote will not be used for an extended period to prevent leakage.
- Dispose of used batteries responsibly according to local regulations.
Troubleshooting
- Remote Not Responding:
- Check if the batteries are inserted correctly and are not depleted. Replace if necessary.
- Verify that the dip switches on the remote control precisely match the settings on your ceiling fan's receiver unit.
- Ensure there are no obstructions between the remote and the fan receiver.
- Limited Operating Range:
- Replace the batteries with new ones.
- Ensure the remote is pointed directly at the fan.
- Radio frequency interference from other devices might be affecting the range. Try operating the remote from a different position.
- Fan or Light Not Functioning Correctly:
- Confirm that the fan's main power supply is on.
- Re-check the dip switch settings on both the remote and the fan receiver.
- Ensure the remote is the correct model (CHQ7096T with yellow light button) for your fan. This remote is not compatible with systems requiring green or red light buttons.
Specifications
| Feature | Detail |
|---|---|
| Brand | Hampton Bay |
| Model Name | CHQ7096T |
| Model Number | CHQ7096T |
| Connectivity Technology | Radio Frequency |
| Maximum Range | 30 Feet |
| Number of Batteries Required | 4 |
| Battery Type | AAA (Lithium-Ion recommended for longevity) |
| Compatible Devices | Hampton Bay Ceiling Fans (CHQ7096T system) |
| Item Weight | 5 Ounces |
| Color | White |
| Special Feature | Ergonomic Design |
Warranty Information
Specific warranty details for this Hampton Bay CHQ7096T Remote Control are not provided in the product information. Please refer to the original purchase documentation or contact the retailer for warranty terms and conditions.
Support Information
For further assistance or technical support regarding your Hampton Bay CHQ7096T Remote Control, please contact the retailer or refer to the Hampton Bay official website for customer service contact details. No specific support contact information was provided with this product.