Ohaus R71MD15

Download PDF
Contents

Ohaus Ranger 7000 Compact Bench Scale R71MD15 User Manual

Model: R71MD15

Introduction

This manual provides essential instructions for the safe and efficient operation, setup, and maintenance of your Ohaus Ranger 7000 Compact Bench Scale, model R71MD15. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage or injury.

Safety Information

Always observe the following safety precautions:

  • Operate the scale on a stable, level surface.
  • Do not exceed the maximum capacity of 15 kg.
  • Avoid exposing the scale to extreme temperatures, humidity, or direct sunlight.
  • Keep the scale clean and free from dust and debris.
  • Disconnect power before cleaning or performing maintenance.
  • Only use the specified AC adapter.

Package Contents

Verify that all items are present:

  • Ohaus Ranger 7000 Bench Scale (R71MD15)
  • Weighing Platform (Stainless Steel)
  • Display Unit
  • AC Power Adapter
  • User Manual (this document)

Setup

1. Unpacking and Placement

Carefully remove all components from the packaging. Place the scale base on a firm, level, and stable surface, free from vibrations and drafts. Ensure adequate space around the scale for operation.

2. Platform Installation

Gently place the stainless steel weighing platform onto the scale base, ensuring it sits securely and does not wobble.

3. Leveling the Scale

Use the adjustable feet on the scale base to level the unit. Check the integrated level indicator (if present, typically a bubble level) to ensure the scale is perfectly level for accurate measurements.

4. Power Connection

Connect the AC power adapter to the scale and then plug it into a suitable power outlet. The scale can also operate on a rechargeable battery (not included) for portable use.

Ohaus Ranger 7000 Compact Bench Scale R71MD15 with stainless steel platform and separate display unit.

This image displays the Ohaus Ranger 7000 Compact Bench Scale. It features a rectangular stainless steel weighing platform and a separate, angled display unit with a full-color WQVGA graphic display and multiple control buttons. The scale base is black with red adjustable feet.

Operating Instructions

1. Power On/Off

Press the POWER button to turn the scale on. Press and hold the POWER button to turn it off.

2. Display Overview

The 4.3-inch full-color WQVGA graphic display shows weight readings, selected units, and various application mode information. Brightness can be adjusted via user controls.

3. Unit Selection

Press the UNIT button to cycle through available weighing units: kg, g, lb, oz, lb:oz. The currently selected unit will be indicated on the display.

4. Basic Weighing

  1. Ensure the scale displays zero. If not, press the ZERO button.
  2. Place the item to be weighed onto the center of the weighing platform.
  3. Read the stable weight displayed on the screen.

5. Tare Function

To weigh an item in a container, first place the empty container on the platform. Press the TARE button to zero the display. Then, place the item into the container; the display will show the net weight of the item.

6. Application Modes

The Ranger 7000 offers various application modes for advanced weighing tasks. Refer to the on-screen menu or specific sections of the full product manual for detailed instructions on using modes such as parts counting, checkweighing, dynamic weighing, and formulation.

Maintenance

1. Cleaning

Wipe the scale surfaces with a damp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure no liquid enters the scale's internal components. The stainless steel platform can be removed for thorough cleaning.

2. Storage

When not in use for extended periods, store the scale in a dry, dust-free environment at room temperature. Disconnect the AC adapter if using battery power, or remove the battery if not in use for a long time.

Troubleshooting

ProblemPossible CauseSolution
Scale does not turn onNo power, faulty adapter, discharged batteryCheck power connection, try another outlet, charge/replace battery.
Inaccurate readingsNot level, vibrations, drafts, calibration neededLevel the scale, move to a stable location, perform calibration.
Display shows "OVERLOAD"Weight exceeds maximum capacityRemove excess weight immediately.

Specifications

FeatureDetail
ModelR71MD15
Capacity15 kg x 0.2 g (15,000g x 0.2 g)
Weighing Unitskg, g, lb, oz, lb:oz
Platform Size14.8 in x 12.2 in
ConstructionStainless Steel (Platform)
Display4.3'' (109 mm) Full-color WQVGA graphic display
PowerAC Power (Included), Rechargeable Battery (Not Included)
Product Dimensions27 x 21 x 13 inches; 21.8 Pounds
Item Model Number1191Q59EA

Warranty and Support

For warranty information, technical support, or service inquiries, please contact Ohaus customer service or visit the official Ohaus website. Keep your purchase receipt for warranty claims.