1. Introduction
This manual provides essential information for the safe and efficient operation of your VELP Scientifica JPV ABS Recirculating Water Vacuum Pump. The JPV model is engineered to ensure constant water recirculation, significantly reducing water consumption in laboratory applications. It is designed to provide reliable vacuum where a consistent water supply might be unavailable.
Key features of this pump include:
- Efficient water recirculation, replacing high water consumption.
- Ability to provide vacuum in areas without a reliable water supply.
- Extremely quiet and vibration-free operation.
- Integrated handles for simplified lifting and transport.
- Adjustable flow rate from 0 up to 22 liters per minute.

Figure 1: VELP Scientifica JPV ABS Recirculating Water Vacuum Pump. This image shows the compact design of the pump, highlighting its robust construction suitable for laboratory environments.
2. Safety Information
Please read and understand all safety instructions before operating the VELP Scientifica JPV pump. Failure to follow these instructions may result in injury or damage to the equipment.
- Electrical Safety: Ensure the pump is connected to a properly grounded power outlet with the correct voltage (230V) and frequency (50-60 Hz). Do not operate with damaged power cords.
- Water Quality: Use clean, deionized, or distilled water in the recirculation tank to prevent mineral buildup and ensure optimal performance.
- Ventilation: Operate the pump in a well-ventilated area to prevent heat buildup.
- Chemical Compatibility: Ensure that any chemicals or vapors being drawn through the vacuum system are compatible with the pump's ABS material and internal components.
- Stable Surface: Place the pump on a stable, level surface to prevent tipping.
- Emergency Shut-off: Familiarize yourself with the location of the power switch for immediate shut-off in case of an emergency.
3. Package Contents
Upon unpacking, verify that all components are present and undamaged. If any items are missing or damaged, contact your supplier immediately.
- VELP Scientifica JPV ABS Recirculating Water Vacuum Pump unit
- Power cord
- Instruction manual
- Vacuum tubing (may be included or sold separately)
4. Setup
Follow these steps to set up your JPV Recirculating Water Vacuum Pump:
- Unpacking: Carefully remove the pump from its packaging and place it on a stable, level laboratory bench.
- Water Fill: Open the fill port (typically located on the top or side) and fill the internal reservoir with approximately 5-7 liters of clean, deionized, or distilled water. Do not overfill. The water level indicator (if present) should be within the recommended range.
- Connect Vacuum Tubing: Attach appropriate vacuum tubing from your application (e.g., rotary evaporator, filtration apparatus) to the vacuum inlet port(s) on the pump. Ensure connections are secure and airtight.
- Power Connection: Connect the power cord to the pump and then to a grounded 230V, 50-60 Hz power outlet.
- Initial Check: Before starting, visually inspect all connections and ensure the water level is correct.
5. Operating Instructions
To operate the VELP Scientifica JPV pump:
- Power On: Flip the main power switch to the 'ON' position. The pump should start circulating water and generating vacuum.
- Adjust Flow Rate: If your model has an adjustable flow rate knob, turn it to achieve the desired vacuum level or water circulation speed for your application (0 to 22 liters per minute).
- Monitor Performance: Observe the vacuum gauge (if equipped) and the performance of your connected apparatus.
- Shut Down: When finished, turn off the main power switch. Disconnect the vacuum tubing from your application.
- Drain (if necessary): For long-term storage or water replacement, drain the water from the reservoir using the drain port.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your JPV pump.
- Water Replacement: Replace the water in the reservoir regularly (e.g., weekly or bi-weekly, depending on usage) to prevent algae growth and mineral buildup.
- Cleaning: Periodically clean the exterior of the pump with a damp cloth. Avoid using harsh chemicals that could damage the ABS material.
- Reservoir Cleaning: If algae or significant mineral deposits occur, drain the reservoir and clean it thoroughly with a mild detergent and brush. Rinse completely before refilling.
- Tubing Inspection: Regularly inspect vacuum tubing for cracks, kinks, or blockages. Replace damaged tubing as needed.
- Storage: If storing the pump for an extended period, drain all water from the reservoir and ensure it is clean and dry.
7. Troubleshooting
Refer to the following table for common issues and their potential solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not turn on | No power supply; Power cord damaged; Internal fuse blown | Check power connection and outlet; Inspect power cord; Contact service for fuse replacement. |
| Poor or no vacuum | Insufficient water level; Leaks in vacuum tubing/connections; Clogged vacuum port; Worn internal components | Check and refill water; Inspect and secure all tubing connections; Clean vacuum ports; Contact service for inspection. |
| Excessive noise or vibration | Pump not on a level surface; Internal obstruction; Motor issue | Ensure pump is on a stable, level surface; Check for foreign objects in water reservoir; Contact service. |
| Water leakage | Loose connections; Damaged reservoir; Worn seals | Tighten all connections; Inspect reservoir for cracks; Contact service for seal replacement. |
8. Specifications
Technical specifications for the VELP Scientifica JPV ABS Recirculating Water Vacuum Pump:
| Specification | Value |
|---|---|
| Model Number | 1183G89EA (F40100541) |
| Brand | VELP Scientifica |
| Material | Acrylonitrile Butadiene Styrene (ABS) |
| Voltage | 230V |
| Frequency | 50-60 Hz |
| Power | 160W |
| Item Weight | 9.98 Kilograms (22 pounds) |
| Flow Rate (Adjustable) | 0 - 22 liters per minute |
| Package Dimensions | 1 x 1 x 1 inches (approximate shipping dimensions) |
| Manufacturer | VELP Scientific, Inc |
9. Warranty and Support
VELP Scientifica products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official VELP Scientifica website.
For technical support, service, or spare parts, please contact your local VELP Scientifica distributor or the manufacturer directly. When contacting support, please have your model number (1183G89EA) and serial number ready.