Thank you for choosing the Ferve F-970 Fast Charger and Jump Starter. This robust unit is designed for efficient charging of all common 12V and 24V lead-acid batteries, including liquid, gel, AGM, and start-stop types. It also features a powerful 450A jump start function, making it an essential tool for workshops and vehicle fleets. This manual provides comprehensive instructions for the safe and effective use, setup, operation, maintenance, and troubleshooting of your Ferve F-970.
Safety Instructions
Always read and understand all safety instructions before operating the Ferve F-970. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ventilation: Operate the charger in a well-ventilated area. Batteries can produce explosive gases.
- Eye and Face Protection: Always wear appropriate eye and face protection when working near batteries.
- Gloves: Wear insulated gloves to prevent electric shock.
- Flammable Materials: Keep the charger and battery away from open flames, sparks, and flammable materials.
- Connection Order: Connect the battery clamps in the correct order (positive to positive, negative to negative, or as specified for jump starting).
- Disconnect Power: Always disconnect the charger from the power outlet before connecting or disconnecting battery clamps.
- Children and Pets: Keep the device out of reach of children and pets.
- Damaged Unit: Do not operate the charger if it has been dropped, damaged, or is not functioning correctly. Contact qualified service personnel.
Product Overview
The Ferve F-970 is a heavy-duty battery charger and jump starter designed for professional use. Its robust construction and integrated wheels ensure durability and ease of transport.

An image showing the Ferve F-970 Fast Charger and Jump Starter. The unit is a robust, wheeled device with a white and red metal housing, a black handle, and red and black battery clamps attached to cables on the side. The front panel displays the 'FERVE FAST F-970' logo.
Key Components:
- Main Unit: Robust metal housing containing the charging and jump starting circuitry.
- Handle: Integrated black handle for easy maneuvering.
- Wheels: Two sturdy wheels for convenient transport.
- Battery Clamps: Heavy-duty red (positive) and black (negative) clamps for secure battery connection.
- Control Panel: Located on the top, featuring switches and indicators for operation.
- Power Cord: For connecting the unit to a mains power supply.
Setup
The Ferve F-970 comes pre-assembled and ready for use. Follow these steps for initial setup:
- Unpacking: Carefully remove the charger from its packaging. Inspect for any signs of damage during transit.
- Placement: Position the charger on a stable, level surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture.
- Cable Management: Ensure all cables (power cord and battery cables) are untangled and free from obstructions to prevent tripping hazards or damage.
Operating Instructions
The Ferve F-970 offers both battery charging and jump starting functionalities.
Battery Charging
- Prepare Battery: Ensure the battery terminals are clean and free of corrosion. If charging a lead-acid battery with removable caps, check electrolyte levels and top up with distilled water if necessary.
- Connect Clamps:
- Connect the red (positive, +) clamp to the positive (+) terminal of the battery.
- Connect the black (negative, -) clamp to the negative (-) terminal of the battery. If the battery is in a vehicle, connect the black clamp to a metal part of the vehicle chassis away from the battery and fuel line.
- Select Voltage: On the charger's control panel, select the appropriate voltage (12V or 24V) corresponding to your battery.
- Connect Power: Plug the charger's power cord into a suitable mains power outlet.
- Start Charging: Turn on the charger. The unit will begin charging at a current of 70A for 12V batteries or 55A for 24V batteries. Monitor the charging process.
- Disconnect: Once charging is complete, first turn off the charger, then unplug it from the mains. Finally, disconnect the black (negative) clamp, followed by the red (positive) clamp.
Jump Start Function (450A)
Use the jump start function only when the vehicle's battery is severely discharged and needs immediate assistance to start the engine.
- Vehicle Off: Ensure the vehicle's ignition is off and all accessories are turned off.
- Connect Clamps:
- Connect the red (positive, +) clamp to the positive (+) terminal of the vehicle's discharged battery.
- Connect the black (negative, -) clamp to a solid, unpainted metal part of the vehicle's engine block or chassis, away from the battery and moving parts.
- Connect Power: Plug the charger's power cord into a suitable mains power outlet.
- Activate Jump Start: Select the jump start mode on the charger (refer to the control panel markings).
- Start Vehicle: Attempt to start the vehicle's engine. Do not crank for more than 5 seconds. If the vehicle does not start, wait at least 1 minute before trying again.
- Disconnect: Once the vehicle starts, immediately turn off the jump start function on the charger. Then, unplug the charger from the mains. Disconnect the black (negative) clamp first, followed by the red (positive) clamp.
Maintenance
Proper maintenance ensures the longevity and optimal performance of your Ferve F-970.
- Cleaning: Disconnect the charger from power before cleaning. Wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Cable Inspection: Regularly inspect the power cord and battery cables for any cuts, fraying, or damage. Replace damaged cables immediately.
- Clamp Care: Keep battery clamps clean and free of corrosion. Clean with a wire brush if necessary.
- Storage: Store the charger in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure cables are neatly coiled to prevent damage.
Troubleshooting
If you encounter issues with your Ferve F-970, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Charger not turning on. | No power from outlet; power cord damaged; internal fuse blown. | Check power outlet with another device. Inspect power cord. If fuse is suspected, contact service. |
| Battery not charging. | Incorrect voltage selected; poor clamp connection; battery severely discharged or faulty. | Verify 12V/24V selection. Ensure clamps are securely connected to clean terminals. Test battery condition. |
| Jump start not working. | Poor clamp connection; vehicle battery completely dead; vehicle electrical issue. | Ensure clamps are securely connected to battery and chassis. Allow a few minutes for the charger to provide some initial charge before attempting to start. Consult a mechanic if vehicle issues persist. |
| Overheating. | Insufficient ventilation; prolonged heavy use. | Ensure adequate airflow around the unit. Allow the charger to cool down before resuming operation. |
For issues not listed here or if solutions do not resolve the problem, please contact Ferve customer support.
Specifications
| Feature | Detail |
|---|---|
| Brand | FERVE |
| Model | F-970 |
| Input Voltage | Standard Mains Power (e.g., 230V AC, 50/60Hz - typical for NL) |
| Output Voltage | 12V / 24V DC |
| Charging Current (12V) | 70 A |
| Charging Current (24V) | 55 A |
| Jump Start Current | 450 A |
| Compatible Battery Types | Lead-acid (liquid, gel, AGM, start-stop) |
| Dimensions (L x W x H) | 43 x 24.5 x 59 cm |
| Item Weight | 27.35 kg |
| Manufacturer | FERVE, S.A. |
| ASIN | B01GTO7U44 |
Warranty and Support
Ferve products are manufactured to high-quality standards. For information regarding warranty coverage, technical support, or service, please refer to the warranty card included with your product or visit the official Ferve website. Please have your model number (F-970) and ASIN (B01GTO7U44) ready when contacting support.