1. Introduction
Thank you for choosing the FERVE F-1830 Digital Multimeter. This device is designed for precise electrical measurements in various applications, suitable for both professional and personal use. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your multimeter. Please read it thoroughly before use and keep it for future reference.
2. Safety Information
To ensure safe operation and avoid damage to the meter, always adhere to the following safety precautions:
- Always inspect the test leads for damage before use. Do not use if insulation is compromised.
- Never exceed the maximum input limits for any function. The maximum operating voltage is 600 Volts.
- Ensure the rotary switch is set to the correct function and range before connecting the test leads to the circuit.
- Use extreme caution when working with live circuits. Avoid contact with bare wires or terminals.
- Do not operate the meter if it appears damaged or if the case is open.
- Replace the battery when the low battery indicator appears to ensure accurate readings.
- Always disconnect the test leads from the circuit before changing functions or ranges.
- Keep hands and fingers behind the probe barriers during measurements.
3. Product Overview
The FERVE F-1830 Digital Multimeter features a robust design with a protective rubber casing for enhanced durability. It includes a clear digital display and an intuitive rotary switch for function selection.

Figure 3.1: Front view of the FERVE F-1830 Digital Multimeter with connected test leads. The display shows '00.0', and the rotary switch is set to the OFF position. The 'HOLD' and 'BACK LIGHT' buttons are visible above the switch.
Components:
- Digital Display: Shows measurement readings.
- Rotary Switch: Selects measurement functions and ranges.
- Input Jacks: Terminals for connecting test leads (VΩmA, COM, 10A).
- HOLD Button: Freezes the current reading on the display.
- BACK LIGHT Button: Activates the display backlight for improved visibility in low-light conditions.
- Protective Rubber Casing: Provides shock absorption and durability.
4. Setup
4.1 Battery Installation
The FERVE F-1830 is powered by a 9V battery (not always included). To install or replace the battery:
- Ensure the multimeter is turned OFF and test leads are disconnected.
- Locate the battery compartment cover on the back of the meter.
- Remove the screw(s) securing the cover and gently lift it off.
- Connect a new 9V battery to the battery clip, observing correct polarity.
- Place the battery into the compartment and replace the cover, securing it with the screw(s).
4.2 Connecting Test Leads
Always use the provided test leads. Connect them as follows:
- Insert the black test lead into the 'COM' (Common) input jack.
- For most measurements (Voltage, Resistance, Diode, Continuity, mA Current), insert the red test lead into the 'VΩmA' input jack.
- For high current measurements (up to 10A), insert the red test lead into the '10A' input jack.
5. Operating Instructions
This section details how to perform various measurements with your FERVE F-1830 multimeter.

Figure 5.1: The FERVE F-1830 Digital Multimeter positioned on a workbench, ready for use. The image highlights its suitability for professional applications.
5.1 DC Voltage Measurement (V=)
Measures direct current voltage from 0 to 600V.
- Connect the black lead to 'COM' and the red lead to 'VΩmA'.
- Set the rotary switch to the desired 'V=' (DC Voltage) range (e.g., 20V, 200V, 600V). If unsure, start with the highest range.
- Connect the test probes in parallel across the component or circuit to be measured.
- Read the voltage value on the display.
5.2 AC Voltage Measurement (V~)
Measures alternating current voltage from 0 to 600V.
- Connect the black lead to 'COM' and the red lead to 'VΩmA'.
- Set the rotary switch to the desired 'V~' (AC Voltage) range (e.g., 200V, 600V).
- Connect the test probes in parallel across the AC source or component.
- Read the voltage value on the display.
5.3 DC Current Measurement (A=)
Measures direct current from 0 to 10A.
- For currents up to 200mA, connect the black lead to 'COM' and the red lead to 'VΩmA'. For currents up to 10A, connect the red lead to '10A'.
- Set the rotary switch to the appropriate 'A=' (DC Current) range (e.g., 200µA, 2mA, 20mA, 200mA, 10A).
- Important: Connect the multimeter in series with the circuit. Break the circuit and insert the meter so that the current flows through it.
- Read the current value on the display.
5.4 Resistance Measurement (Ω)
Measures resistance from 0 to 2 MOhms.
- Ensure the circuit is de-energized before measuring resistance.
- Connect the black lead to 'COM' and the red lead to 'VΩmA'.
- Set the rotary switch to the desired 'Ω' (Resistance) range (e.g., 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ).
- Connect the test probes across the component whose resistance is to be measured.
- Read the resistance value on the display.
5.5 Continuity Test
Checks for an open or closed circuit, indicated by an audible tone.
- Ensure the circuit is de-energized.
- Connect the black lead to 'COM' and the red lead to 'VΩmA'.
- Set the rotary switch to the continuity symbol (often a speaker icon).
- Connect the test probes across the circuit or component. A continuous beep indicates continuity (a closed circuit).
5.6 Diode Test
Tests the functionality of diodes.
- Ensure the circuit is de-energized.
- Connect the black lead to 'COM' and the red lead to 'VΩmA'.
- Set the rotary switch to the diode symbol.
- Connect the red probe to the anode and the black probe to the cathode of the diode. The display will show the forward voltage drop.
- Reverse the probes. The display should show 'OL' (Open Loop) for a good diode.
5.7 Special Functions: Back Light and Hold
- Back Light: Press the 'BACK LIGHT' button to illuminate the display for better visibility in dark environments. Press again to turn off.
- Hold: Press the 'HOLD' button to freeze the current reading on the display. This is useful when taking measurements in hard-to-reach areas where the display cannot be easily viewed. Press again to release the hold function.
6. Maintenance
6.1 Cleaning
Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is dry before use.
6.2 Battery Replacement
Refer to section 4.1 for battery replacement instructions. Replace the battery promptly when the low battery indicator appears on the display to maintain measurement accuracy.
6.3 Storage
When not in use for extended periods, remove the battery to prevent leakage. Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
If you encounter issues with your FERVE F-1830, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No display or dim display | Dead or low battery; Incorrect battery installation | Replace battery; Check battery polarity |
| Incorrect readings | Incorrect function/range selection; Damaged test leads; Meter malfunction | Verify rotary switch setting; Inspect and replace test leads if damaged; Contact support if malfunction persists |
| 'OL' (Overload) displayed | Measurement exceeds selected range; Open circuit (for continuity/resistance) | Select a higher range; Check circuit for breaks |
| No continuity beep | Open circuit; Faulty component | Check connections; Test component separately |
8. Specifications
The following are the technical specifications for the FERVE F-1830 Digital Multimeter:

Figure 8.1: The FERVE F-1830 Digital Multimeter with an overlay showing key specifications including model number, maximum voltage, and physical dimensions.
- Model Number: F-1830
- Manufacturer: FERVE, S.A.
- Dimensions (L x W x H): 13.8 x 6.9 x 3.1 cm (5.43 x 2.72 x 1.22 inches)
- Weight: 300 grams (0.66 lbs)
- Power Source: Battery Powered (typically 9V)
- Maximum Operating Voltage: 600 Volts
- DC Voltage Range: 0 - 600 V
- AC Voltage Range: 0 - 600 V
- DC Current Range: 0 - 10 A
- Resistance Range: 0 - 2 MOhms
- Functions: DC Voltage, AC Voltage, DC Current, Resistance, Continuity Test, Diode Test
- Special Features: Back Light, Hold Function, Protective Rubber Casing
- Safety Rating: CAT III 600V
9. Warranty and Support
The FERVE F-1830 Digital Multimeter comes with a 3-year warranty, ensuring quality and reliability. FERVE S.A. is committed to providing high-quality products and customer satisfaction.
For technical assistance, warranty claims, or any questions regarding your multimeter, please contact FERVE's specialized technical service. Contact information can typically be found on the product packaging or the official FERVE website.
For more information about FERVE products, please visit www.ferve.com.