Introduction

The iGaging EZ-VIEW PLUS Digital Readout is designed to provide precise linear measurement capabilities for various machine tools such as router tables, planers, table saw fences, milling machines, and lathes. It features an X-Large LCD display for easy reading and a magnetic remote display for flexible installation. This manual provides essential information for the setup, operation, maintenance, and troubleshooting of your EZ-VIEW PLUS Digital Readout.

Product Overview

iGaging EZ-VIEW PLUS Digital Readout system with display unit, mounting arm, and linear scale.

Figure 1: The iGaging EZ-VIEW PLUS Digital Readout system, showing the main display unit, the articulated mounting arm, the connecting cable, and the linear scale with its sensor block.

Key Features:

  • Industrial grade Aluminum rule, which can be easily cut to fit various applications.
  • Super Large, easy-to-read X-Large LCD display showing inch, decimal, fractional, and metric readings.
  • Magnetic Remote display with a 76-inch cord for flexible installation and access.
  • Versatile mounting: Can be used in vertical, horizontal, or any other position.
  • Measurement range (Travel): 0-6 inches.
  • Accuracy: 0.002 inches per 6 inches.
  • Reading resolution: 0.001 inches / 0.01 mm / 1/128th inch.
  • Fractions resolution can be set to max 1/32, 1/64, or 1/128.
  • Includes brackets for both vertical and horizontal mounting.
  • Preset function allows setting any value at any point on the scale.
  • Data output port available (data cable sold separately).
  • AC power port available (AC adapter sold separately).

Setup and Installation

Proper installation is crucial for accurate measurements. The iGaging EZ-VIEW PLUS DRO can be mounted in various configurations depending on your machine and application.

Components:

  • Digital Readout Display Unit
  • Linear Scale (Aluminum Rule)
  • Sensor Block (integrated with the scale)
  • Mounting Brackets (for vertical and horizontal applications)
  • Connecting Cable (76 inches)

Mounting Considerations:

  1. Identify Mounting Location: Determine the best location on your machine (e.g., router table fence, planer bed, milling machine axis) where the linear scale can move freely and parallel to the desired measurement axis.
  2. Prepare Surfaces: Ensure mounting surfaces are clean, flat, and free of debris.
  3. Attach Linear Scale: Securely attach the linear scale to one part of your machine. The aluminum rule can be cut to length if necessary, but ensure the cutting process does not damage the measurement track.
  4. Attach Display Unit: Mount the display unit using the provided brackets. The magnetic back allows for flexible positioning on ferrous surfaces. Ensure the display is easily visible and accessible.
  5. Connect Cable: Plug the 76-inch cable from the linear scale's sensor block into the display unit. Ensure a secure connection.
  6. Power Supply: The unit requires 2 Lithium Metal batteries. Insert them into the battery compartment. An optional AC adapter can be used via the AC power port (sold separately).
  7. Test Movement: Manually move the machine part to which the scale is attached to ensure smooth, unobstructed travel and that the sensor block reads accurately across the entire range.
Close-up of the iGaging EZ-VIEW PLUS display unit showing buttons and LCD screen.

Figure 2: Detail of the EZ-VIEW PLUS display unit, highlighting the LCD screen and control buttons (mm/in/F, SET, Preset, Power, ZERO, Hold).

Close-up of the linear scale component of the iGaging EZ-VIEW PLUS DRO.

Figure 3: The linear scale component, showing the aluminum rule and the integrated sensor block that slides along it.

Operating Instructions

Basic Operation:

  1. Power On/Off: Press the Power button (red circle with line) to turn the unit on or off.
  2. Zero Setting: Move the machine part to your desired starting point. Press the ZERO button to set the current position as zero. This allows for relative measurements from any point.
  3. Unit Conversion: Press the mm/in/F button to cycle through measurement units: millimeters (mm), inches (in), and fractions (F).
  4. Hold Function: Press the Hold button to freeze the current reading on the display. Press again to release.

Advanced Functions:

  1. Preset Function: The EZ-VIEW PLUS features a PRESET function. Press the Preset button to enter a specific value at the current position. This is useful for setting a known reference point other than zero. Follow the on-screen prompts to input the desired value.
  2. Fractional Resolution Adjustment: The fractional resolution can be set to 1/32, 1/64, or 1/128. Refer to the display unit's menu or specific button combinations (often involving the SET button) for this adjustment.
  3. Data Output: The unit has a data output port. A separate data cable (not included) is required to connect the DRO to a computer or data logger for recording measurements.

Maintenance

Regular maintenance ensures the longevity and accuracy of your iGaging EZ-VIEW PLUS Digital Readout.

  • Cleaning: Keep the linear scale and sensor block clean and free of dust, chips, and lubricants. Use a soft, dry cloth. Avoid using harsh chemicals or solvents that could damage the display or scale.
  • Battery Replacement: When the display indicates low battery, replace the 2 Lithium Metal batteries promptly to ensure continuous operation and prevent data loss.
  • Cable Inspection: Periodically inspect the connecting cable for any signs of wear, cuts, or damage. A damaged cable can lead to intermittent readings or complete failure.
  • Storage: When not in use for extended periods, store the unit in a clean, dry environment, away from extreme temperatures and direct sunlight.

Troubleshooting

ProblemPossible CauseSolution
Display does not turn on.Dead batteries or incorrect battery insertion.Replace batteries, ensuring correct polarity. Check if AC adapter (if used) is properly connected and functional.
Inaccurate or erratic readings.Dirty linear scale or sensor block; loose cable connection; sensor misalignment; electromagnetic interference (EMI).Clean scale and sensor. Ensure cable is securely plugged in. Verify sensor is properly aligned and moving smoothly along the scale. Minimize sources of EMI.
Display freezes or lags.Low battery; cable issue; internal electronics issue.Replace batteries. Check cable for damage. If problem persists, contact iGaging support.
Cannot set zero or preset value.Incorrect button sequence; internal error.Refer to "Operating Instructions" for correct button usage. Try turning the unit off and on again.

Specifications

  • Model: 35-706-P+
  • Measurement Range (Travel): 0-6 inches
  • Accuracy: 0.002 inches per 6 inches
  • Reading Resolution: 0.001 inches / 0.01 mm / 1/128th inch
  • Fractional Resolution Settings: 1/32, 1/64, 1/128
  • Repeatability: 0.001 inches / 0.05 mm per 6 inches
  • Display: X-Large LCD
  • Power Source: 2 Lithium Metal batteries (required)
  • Material: Aluminum (rule)
  • Product Dimensions: 14.25 inches (L) x 2.62 inches (W) x 1.62 inches (H)
  • Item Weight: 1.12 Pounds
  • Cable Length: 76 inches (remote display cord)

Warranty and Support

iGaging products are manufactured to high standards. For warranty information or technical support, please contact iGaging directly. Keep your purchase receipt as proof of purchase.

Manufacturer: iGaging

For further assistance, visit the official iGaging store on Amazon: iGaging Store

© 2024 iGaging. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.