1. Introduction and Overview
The Aven Cyclops HDMI Digital Microscope is an innovative inspection scope designed to provide high-quality magnified videos and single frames directly on an HD monitor. This system eliminates the need for a PC, allowing operators to view images in crystal clear 1080p resolution while looking straight ahead at a large screen, significantly reducing eye strain and user fatigue associated with traditional microscopes. It is ideal for high-volume applications such as parts inspection and assembly operations.
Key features include a large working distance, 30 adjustable LEDs for optimal illumination, and a magnification range up to 270x on a 21.5-inch HD monitor. The system is highly customizable with various optional accessories to meet specific inspection needs.
2. Package Contents
Upon unpacking your Aven Cyclops HDMI Digital Microscope, please ensure all the following items are present:
- Cyclops HDMI Digital Microscope unit
- 4x Objective lens
- HDMI cable
- Power adapter
- Metal stand
- White balance card
- IR remote control
3. Setup
Follow these steps to set up your Aven Cyclops HDMI Digital Microscope:
- Carefully remove all components from the packaging.
- Assemble the metal stand by securely attaching the vertical post to the base.
- Mount the Cyclops HDMI Digital Microscope unit onto the vertical post of the stand. Ensure it is securely fastened at a suitable height for your workspace.
- Connect one end of the provided HDMI cable to the HDMI output port on the microscope unit and the other end to the HDMI input port on your HD monitor.
- Connect the power adapter to the microscope unit's power input and then plug it into a standard electrical outlet.
- Power on the microscope unit and your HD monitor. The microscope's live image should now be displayed on the monitor.

Figure 3.1: Aven Cyclops HDMI Digital Microscope setup with monitor.
4. Operating Instructions
The Aven Cyclops HDMI Digital Microscope is designed for ease of use, allowing direct viewing on an HD monitor without the need for a computer. All major functions are controlled via the included infrared (IR) remote.
4.1 Basic Operation
- Power On/Off: Use the power button on the IR remote to turn the unit on or off.
- Placement: Place the object you wish to inspect directly under the microscope's objective lens on the metal stand.
- Adjusting Height: Use the adjustment knob on the stand to raise or lower the microscope unit, bringing the object into approximate focus. The large 9-inch working distance provides ample space for manipulation.

Figure 4.1: Microscope in use, displaying a circuit board on the monitor.
4.2 Remote Control Functions
The IR remote provides comprehensive control over the microscope's features:
- Optical Zoom: Adjust the optical magnification level.
- Step Zoom: Fine-tune the zoom in incremental steps.
- Freeze Mode: Pause the live image to examine a still frame.
- White Balance: Adjust the color balance for accurate color representation.
- Sharpness: Enhance or reduce the sharpness of the image.
- Lighting: Control the intensity of the 30 integrated LED lights.
- Focus: Utilize the unique autofocus feature to maintain clear focus even when tilting, rotating, or lifting objects.

Figure 4.2: User interacting with the microscope via the IR remote.
4.3 Image Examples

Figure 4.3: Magnified view of a watch mechanism.

Figure 4.4: Magnified view of a coin surface.

Figure 4.5: Magnified view of a circuit board.
4.4 Official Product Video
Video 4.1: Official product overview of the Aven Cyclops HDMI Digital Microscope, demonstrating its features and capabilities.
5. Maintenance
Proper maintenance ensures the longevity and optimal performance of your Aven Cyclops HDMI Digital Microscope.
- Cleaning Lenses: Use a soft, lint-free cloth specifically designed for optical lenses to gently wipe the objective lens. For stubborn smudges, a small amount of lens cleaning solution can be applied to the cloth, not directly to the lens.
- Cleaning Unit: Wipe the main unit and stand with a dry or slightly damp, soft cloth. Avoid using abrasive cleaners or solvents.
- Storage: When not in use, store the microscope in a clean, dry environment, away from direct sunlight and extreme temperatures. Consider covering the unit to prevent dust accumulation.
- Handling: Always handle the microscope with care. Avoid dropping or subjecting it to strong impacts.
6. Troubleshooting
If you encounter issues with your Aven Cyclops HDMI Digital Microscope, refer to the following common troubleshooting steps:
- No Image on Monitor:
- Ensure the microscope unit and monitor are both powered on.
- Verify that the HDMI cable is securely connected to both the microscope and the monitor.
- Check that the monitor's input source is set to the correct HDMI port.
- Blurry Image:
- Adjust the height of the microscope unit on the stand to bring the object into approximate focus.
- Use the focus controls on the IR remote to fine-tune the image sharpness.
- Ensure the objective lens is clean and free of dust or smudges.
- LED Lights Not Working:
- Check if the microscope unit is powered on.
- Adjust the lighting intensity using the IR remote.
- Remote Control Not Responding:
- Ensure there are no obstructions between the remote and the microscope's IR receiver.
- Replace the batteries in the IR remote.
7. Specifications
| Specification | Value |
|---|---|
| Model Number | 26700-401 |
| Brand | Aven |
| Magnification Maximum | 270 x (on 21.5" HD monitor) |
| Output | HDMI (1080p) |
| Light Source Type | LED (30 adjustable LEDs) |
| Working Distance | 9 inches (approximate) |
| Item Weight | 4.8 Pounds |
| Material | Metal |
| Color | White |
| Date First Available | May 7, 2016 |
8. Warranty and Support
Aven products are manufactured to the highest quality standards and are warranted against defects in materials and workmanship. For specific warranty details, registration, or technical support, please visit the official Aven website or contact their customer service department. Please have your model number and purchase information ready when seeking support.