Beetech ST-9283

Beetech ST-9283 Handheld Digital Thermometer User Manual

Model: ST-9283 | Brand: Beetech

1. Introduction

This manual provides detailed instructions for the safe and effective use of your Beetech ST-9283 Handheld Digital Thermometer. This device is designed for accurate temperature measurement in various applications, including industrial settings, bakeries, food processing, and refrigeration. Please read this manual thoroughly before operating the thermometer and retain it for future reference.

2. Product Overview

The Beetech ST-9283 is a compact and versatile digital thermometer featuring a stainless steel probe for precise temperature readings. It includes a clear digital display and user-friendly buttons for various functions.

Key Features:

  • Wide Measurement Range
  • Stainless Steel Probe
  • Selectable Temperature Units (°C / °F)
  • Data Hold Function
  • Maximum and Minimum Temperature Memory
  • Alarm Function
  • Auto Power Off
Beetech ST-9283 Handheld Digital Thermometer front view

Image 1: Front view of the Beetech ST-9283 Handheld Digital Thermometer, showing the digital display, control buttons (OFF/ON, °C/°F, MAX/MIN, HOLD), and the retractable stainless steel probe.

Included Components:

  • Beetech ST-9283 Digital Thermometer
  • Temperature Sensor Probe
  • User Manual
  • Battery (may not be pre-installed)

3. Getting Started

3.1 Unpacking and Inspection

Carefully remove the thermometer from its packaging. Inspect the device for any signs of damage. If any damage is found, do not use the thermometer and contact customer support.

Beetech ST-9283 Handheld Digital Thermometer in packaging

Image 2: The Beetech ST-9283 Digital Thermometer shown in its retail packaging, highlighting its handheld design and digital display.

3.2 Battery Installation

The thermometer requires one 1.5V AAA (UM4/LR44 equivalent) battery. Batteries are typically not included.

  1. Locate the battery compartment cover on the back of the unit.
  2. If secured by screws, use a small screwdriver to loosen them.
  3. Carefully remove the battery cover.
  4. Insert the new 1.5V AAA battery, ensuring correct polarity (+ and -).
  5. Replace the battery cover and tighten any screws if applicable.

4. Operation

4.1 Power On/Off

  • To Power On: Press the ON/OFF button once. The thermometer will perform a self-test, displaying a full segment flash before showing the normal display.
  • To Power Off: Press and hold the ON/OFF button for approximately 3 seconds, then release. Alternatively, press the ON/OFF button once if the unit is already on and not in a special mode.

4.2 Temperature Measurement

  1. Ensure the thermometer is powered on.
  2. Unwind the sensor cord completely.
  3. Penetrate the stainless steel probe into the substance to be measured by approximately 25mm (1 inch).
  4. Wait for the reading on the digital display to stabilize. This indicates the current temperature.

4.3 Unit Selection (°C / °F)

To switch between Celsius (°C) and Fahrenheit (°F) temperature units:

  • Press the °C/°F button once. The display will toggle between the two units.

4.4 Data Hold Function

To hold the current temperature reading on the display:

  • Press the HOLD button once. The current reading will be frozen, and the "HOLD" icon along with "°C" or "°F" will flash on the display.
  • To release the hold function and return to normal display, press the HOLD button once again.

4.5 Maximum and Minimum Temperature Memory

The thermometer can store the maximum and minimum temperatures recorded during a measurement session.

  1. Press the MAX/MIN button once to display the maximum temperature reading. The "MAX" icon will flash.
  2. Press the MAX/MIN button again to display the minimum temperature reading. The "MIN" icon will flash.
  3. Press the MAX/MIN button a third time to return to the normal temperature display.
  4. To clear the recorded maximum and minimum temperatures from memory, switch off the thermometer.
Beetech ST-9283 Handheld Digital Thermometer packaging with detailed instructions

Image 3: Back of the Beetech ST-9283 Digital Thermometer packaging, showing detailed operational instructions, features, and specifications.

5. Maintenance and Care

5.1 Cleaning

  • Wipe the thermometer body with a clean, damp cloth. Do not use abrasive cleaners or immerse the unit in water.
  • Clean the stainless steel probe thoroughly after each measurement, especially when used with food or in industrial applications, to prevent cross-contamination.

5.2 Battery Replacement

When the display becomes dim or the thermometer functions erratically, it is time to replace the battery. Follow the steps outlined in Section 3.2.

5.3 Storage

Store the thermometer in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, remove the battery to prevent leakage.

6. Safety Information

  • Do not put the test probe inside an oven or microwave oven.
  • Keep the device out of reach of children.
  • Do not expose the thermometer to extreme temperatures, humidity, or direct sunlight for prolonged periods.
  • Do not attempt to disassemble or modify the thermometer. This will void the warranty and may cause damage or injury.
  • Dispose of used batteries according to local regulations.

7. Specifications

ParameterDetail
ModelST-9283
Measurement Range-50°C to +300°C (-58°F to +572°F)
Accuracy±1°C for -20°C to +200°C (±1.8°F for -4°F to +392°F); otherwise ±2°C (±4°F)
Resolution0.1°C between -19.9°C to 199.9°C; otherwise 1°C
Sampling Rate1 second
Battery Type1 x 1.5V AAA (UM4 / LR44 equivalent)
Probe SizeØ5 x 120 mm (L)
Sensor Cord Length1000 mm
Ambient Temperature-10°C to 50°C (14°F to 122°F)
Auto Power OffAfter 10 minutes of inactivity
Outer MaterialPlastic
Item Weight120 g
Indoor/Outdoor UsageIndoor

8. Troubleshooting

If you encounter issues with your thermometer, please refer to the following common solutions:

  • No Display / Dim Display: Check if the battery is installed correctly. Replace the battery if it is low or depleted.
  • Inaccurate Readings: Ensure the probe is fully inserted into the substance. Clean the probe thoroughly. Verify that the ambient temperature is within the specified operating range.
  • Buttons Unresponsive: Try removing and reinserting the battery to reset the device.

If problems persist after attempting these steps, please contact customer support.

9. Warranty and Support

Beetech products are manufactured to high-quality standards. For information regarding warranty coverage, technical support, or service, please refer to the contact details provided with your purchase documentation or visit the official Beetech website. Please retain your proof of purchase for warranty claims.

Related Documents - ST-9283

Preview BEETECH H-801 Digital Multimeter - Specifications and Features
Detailed specifications and features for the BEETECH H-801 Digital Multimeter, including DC/AC voltage, current, resistance, capacitance, and more. Learn about its manual ranging, backlight, and testing capabilities.
Preview ABQIndustrial ST-329 LED Stroboscope: High-Performance Speed Measurement
Discover the ABQIndustrial ST-329 LED Stroboscope, a permanent mount strobo-scope array offering bright, stable light and precise speed measurements for industrial applications. Features wide flash range, long-life LEDs, and versatile mounting.
Preview SecurityTronix ST-THERMSCAN-1 Wall Mounted Non-Contact Forehead Thermometer User Manual and Warranty
User manual and warranty details for the SecurityTronix ST-THERMSCAN-1 Wall Mounted Non-Contact Forehead Thermometer. This guide covers specifications, operation, installation, and warranty terms for the non-contact temperature screening device.
Preview LCN Special Template Chart for Door Closers
A comprehensive chart detailing LCN special templates for various door closer series, including 4040XP, 2210, 4000, 1460, 5030, 2030, 3130, 4116, 4000T, 1460T, 2310ME, 4310ME, 4050T, 1260, and 4020 series. The chart specifies application types, mounting details, and necessary components or modifications for each special template.
Preview Infiniti QX56 Steering System & Heated Wheel Service Manual
Explore comprehensive service procedures, diagnostic guides, and technical specifications for the Infiniti QX56 steering system. This manual details the heated steering wheel functionality, including component descriptions, troubleshooting steps, and maintenance protocols.
Preview SUITU ST-6697Pro/Plus Cordless Car Vacuum Cleaner User Manual
Official user manual for the SUITU ST-6697Pro and ST-6697Plus cordless car vacuum cleaners, detailing product specifications, safe usage instructions, operation, and maintenance procedures.