Introduction
Thank you for choosing the Camry CR 7905 Evaporative Cooler. This versatile appliance is designed to provide efficient air cooling, humidification, and purification, enhancing the comfort of your indoor environment. Please read this manual thoroughly before operating the device to ensure safe and optimal performance. Keep this manual for future reference.
Important Safety Instructions
- Always ensure the power supply matches the voltage specified on the rating label.
- Do not immerse the appliance, cord, or plug in water or other liquids.
- Unplug the unit from the power outlet when not in use, before filling or emptying the water tank, and before cleaning.
- Do not operate the appliance with a damaged cord or plug, or after the appliance malfunctions or has been damaged in any manner.
- Place the unit on a stable, flat surface to prevent tipping and water spillage.
- Keep the appliance out of reach of children and pets.
- Do not block air inlets or outlets.
- Only use clean water in the water tank. Do not add any chemicals or additives other than those recommended by the manufacturer.
- Regularly clean the water tank and filters to prevent mold and odor buildup.
Product Overview
The Camry CR 7905 is a compact and efficient evaporative cooler designed for personal comfort. It combines cooling, humidification, and air purification functions.

Figure 1: Front view of the Camry CR 7905 Evaporative Cooler, showing the main body, control panel on top, and casters at the base.
Main Components:
- Control Panel: Located on the top of the unit for manual operation.
- Air Outlet: Front grille where cooled and humidified air is discharged.
- Water Tank: Removable tank at the bottom for water and ice packs.
- Air Filter: Located at the rear, filters incoming air.
- Cooling Pad: Inside the unit, absorbs water for evaporative cooling.
- Casters: Wheels at the base for easy mobility.
- Remote Control: For convenient operation from a distance.
- Ice Packs: Two reusable ice packs included to enhance cooling.

Figure 2: Detailed view of the control panel with buttons for Speed, Swing, Off, Mode, Sleep, Nature, Humidify, On, and Timer settings.

Figure 3: Rear view of the unit showing the air filter compartment with the filter removed, revealing the green cooling pad.

Figure 4: Close-up of the water tank with two blue ice packs inserted, showing the MIN and MAX fill lines.
Setup Guide
- Unpack the Unit: Carefully remove the evaporative cooler from its packaging. Retain all packaging materials for future storage or transport.
- Position the Cooler: Place the unit on a firm, level surface. Ensure there is adequate space around the unit (at least 20 cm) for proper airflow. Avoid placing it directly against walls or furniture. The integrated casters allow for easy movement.
- Fill the Water Tank:
- Pull out the water tank from the bottom rear of the unit.
- Fill the tank with clean tap water. Do not exceed the "MAX" fill line (8-liter capacity).
- For enhanced cooling, place the two included ice packs (after freezing them) into the water tank.
- Slide the water tank back into the unit until it clicks into place.
- Connect Power: Plug the power cord into a standard electrical outlet. Ensure the outlet voltage matches the unit's requirements.
Operating Instructions
Control Panel and Remote Control:
The unit can be operated using the touch control panel on top or the included remote control. The functions are identical.
- ON/OFF Button: Press to turn the unit on or off.
- SPEED Button: Cycles through fan speeds: Low (L), Medium (M), High (H).
- SWING Button: Activates or deactivates the automatic horizontal oscillation of the air louvers for wider air distribution.
- MODE Button: Selects the operating mode:
- Normal: Constant fan speed.
- Natural: Simulates natural breeze by varying fan speed.
- Sleep: Gradually reduces fan speed for quiet operation during sleep.
- HUMIDIFY Button: Activates the evaporative cooling function by engaging the water pump. The air will be cooled and humidified. Press again to turn off humidification.
- TIMER Button: Sets the operating time before the unit automatically turns off. Press repeatedly to cycle through settings: 0.5h, 1h, 2h, 4h. The maximum timer setting is 7.5 hours (achieved by combining settings, e.g., 4h + 2h + 1h + 0.5h).
Maintenance
Regular cleaning and maintenance will ensure the longevity and efficient operation of your evaporative cooler.
Cleaning the Water Tank:
- Unplug the unit from the power outlet.
- Pull out the water tank.
- Empty any remaining water.
- Clean the tank with a soft cloth and mild detergent. Rinse thoroughly with clean water.
- Allow the tank to air dry completely before reinserting. This helps prevent mold and mildew growth.
Cleaning the Air Filter and Cooling Pad:
- Unplug the unit.
- Remove the air filter from the rear of the unit (refer to Figure 3).
- Gently rinse the air filter and cooling pad under running water to remove dust and debris. For stubborn dirt, use a soft brush.
- Allow both components to dry completely before reassembling them into the unit.
- Inspect the cooling pad periodically for mineral buildup. If heavily scaled, it may need replacement.
General Cleaning:
- Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Ensure no water enters the control panel or other electrical parts.
Storage:
- Before storing, ensure the water tank is empty and clean, and all filters and pads are dry.
- Store the unit in a cool, dry place, preferably in its original packaging, away from direct sunlight and extreme temperatures.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power supply. Power cord not properly connected. | Check if the unit is plugged into a working outlet. Ensure the power cord is securely connected. |
| Weak airflow. | Air filter or cooling pad is dirty. Air inlets/outlets are blocked. | Clean the air filter and cooling pad. Ensure there are no obstructions around the unit. |
| No cooling effect. | Water tank is empty. Humidify function is not activated. Cooling pad is dry or dirty. | Fill the water tank. Press the HUMIDIFY button. Ensure the cooling pad is wet and clean. |
| Unusual noise. | Unit is not on a level surface. Water pump issue (if humidify is on). | Place the unit on a flat, stable surface. Check water level; if noise persists, contact support. |
| Odor from unit. | Stagnant water or dirty filter/cooling pad. | Empty and clean the water tank thoroughly. Clean or replace the air filter and cooling pad. |
If the problem persists after attempting these solutions, please contact customer support.
Specifications
| Model | CR 7905 |
| Brand | CAMRY |
| Power Consumption | 325W |
| Water Tank Capacity | 8 Liters |
| Airflow Capacity | Up to 830 m³/h |
| Functions | Cooling, Humidification, Air Purification, Ventilation |
| Fan Speeds | 3 (Low, Medium, High) |
| Operating Modes | Normal, Natural, Sleep |
| Timer | 0.5h to 7.5h |
| Control | Touch Panel, Remote Control |
| Dimensions (L x W x H) | Approx. 30 x 30 x 10 cm |
| Weight | Approx. 6.25 kg |
Warranty and Support
For warranty information, please refer to the warranty card included with your purchase or contact your retailer. For technical support or service inquiries, please contact the CAMRY customer service department. Contact details can typically be found on the manufacturer's website or on your purchase receipt.
Please have your model number (CR 7905) and purchase date ready when contacting support.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.